USB In-Line Field Calibratable Signal Conditioner
The IN-USBH field calibratable In-Line Signal Conditioner adds digital USB output to mV/V pressure or load transducers. Free downloadable OMEGA PC software takes the data from the transducer directly to the digital domain, turning your laptop or Windows® tablet (with USB connection) into a virtual meter, chart recorder, and data logger. Export logged data to spreadsheet format for later viewing/analysis. The PC-connected IN-USBH provides regulated excitation to the transducer so that no external power supply is used. Sampling rates are adjustable up to 1000 Hz for dynamic or slow moving applications. Mounting bracket is included. Transducer interconnecting cable can be purchased separately. The IN-USBH is compatible with mV pressure and load sensors that meet the stated transducer requirements.
Resolution | Up to 5.5 significant figures |
Minimum Isolation | 2 MΩ @ 50 Vdc case to output terminations |
A to D Conversion | 24 bit |
Thermal Error | 0.001% FSO/°C |
Linearity Error | 0.001% FSO |
Bandwidth | Up to 1000 updates per second typical (± 3%) |
Weight (Typical) | 200 g (7.1 oz) (in-line signal conditioner and USB cable) |
Operating Temperature Range | -40 to 80°C (-40 to 176°F) |
Connection, Transducer Side | PT1H-10-6P 6-pin twist-lock male connector |
Connection, USB Side | 2 m (6') USB 2.0 cable |
Transducer Requirements | |
Bridge Sensitivity | 1 to 400 mV/V |
Bridge Reistance | 350Ω to 15,000Ω |
Excitation Voltage | 4.1 Vdc (Transducer must be able to function at specified voltage) |
OMEGA IN-USBH USB in-line field calibratable signal conditioner - Data sheet 2.9 MB |