` IN-UVI Wheatstone Bridge In-Line Amplifier w/ Field Selectable I/O

OMEGA

IN-UVI Wheatstone Bridge In-Line Amplifier w/ Field Sele...

Wheatstone Bridge In-Line Amplifier

Call Today!
800-567-8686 Normally ships in 2-3 Weeks

  Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

 The OMEGA IN-UVI in-line signal conditioner is housed in a rugged stainless steel enclosure, which is connected between the transducer and a readout instrument. The signal conditioner supplies a highly regulated bridge excitation voltage for the transducer and converts the millivolt signal of the transducer to 0 to 5, 0 to 10, ±5, ±10 Vdc or 4 to 20, 12 ± 8 mA.

 
The IN-UVI features include two selectable excitation voltages, programmable gain amplifier for signals from 0.5 mV/V to 4 mV/V, wide zero adjustment range and an isolated shunt calibration relay for quick field setup. All output options and excitation voltages are field selectable.
 
Ready-Made Cable Assemblies are now available to connect the IN-UVI to mV/V output sensors and to the power supply and display (see Specs for details).
 

• Wide Range of Field Selectable Inputs and Outputs
• Ready-Made Cable Assemblies for Transducer Connection Now Available!
• Input/Output Isolation
• Low Thermal Drift

Supply Voltage 22 to 32 Vdc isolated from output
Isolation Input to Output 500 Vdc
Capacitance 0.022 µF
Resistance 100 MΩ
Input Current 90 mA maximum (must be capable of supplying 200 mA)
Voltage Output ±5 volts, ±10 volts at 2 mA maximum
Output Resistance 60 Ω
Noise 10 mV peak to peak @ 3 mV/V voltage mode (10 Vdc) 20 uA peak to peak current mode
Short Circuit Protection Yes +output to -output
Current Output 4 to 20 mA, 12 mA zero ±8 mA outputs field programmable
Maximum Load Resistance 700 Ω at 20 mA
Operating Temperature -20 to 60°C (0 to 140°F)
Response Time 200 uS (0 to 63%)
Excitation Voltage 5 or 10 field programmable
Excitation Max Current 30 mA @ 10 Vdc
Sensor Input Range 0.5 mV/V to 4 mV/V in 0.5 steps
Shunt Cal Yes; remotely activated
Environmental Protection IP65
Long Term Zero Drift 0.1%/year
Temperature Affects
Zero 0.001%/°F (Auto zero front end)
Span 0.0025%/°F
Linearity 0.01%
Adjustment Range
Zero ±30%
Span ±20% fine ±40% coarse
Adjustment Location Behind connector endcaps
EMC Affect <0.1% per en 61326-1 (industrial)
Dimensions 134.8 L x 34.8 H x 31.2 mm D (5.3 x 1.37 x 1.23)
Transducer Requirements
Bridge Excitation 5 Vdc or 10 Vdc
Bridge Sensitivity 1 to 8 mV/V @ 5 Vdc EXC, 0.5 to 4 mV/V for 10 Vdc EXC
Bridge Resistance 350 to 5000 Ω*
Time constant 0 to 63% (200 µS for a 350 Ω bridges/1.2 mS for a 5000 O bridge)

 • Use with Miniature Load Cells

• Extent the range of mV/V Pressure Transducers
• Wheatstone Bridge Transducers

Item
Description
Availability
Price
Field Mountable M8 and M12 Connectors
Normally ships in 2-3 Weeks
Call Today!
800-567-8686
Cable assembly, 4 conductor, PVC insulation, wiring code 3
Normally ships in 2-3 Weeks
Call Today!
800-567-8686
Cable assembly, 4 conductor, PVC insulation, wiring code 2A
Normally ships in 2-3 Weeks
Call Today!
800-567-8686
Cable assembly, 4 conductor, PVC insulation, wiring code 4
Normally ships in 2-3 Weeks
Call Today!
800-567-8686
Cable assembly, 4 conductor, FEP insulation, wiring code 6
Normally ships in 2-3 Weeks
Call Today!
800-567-8686
Cable assembly, 4 conductor, PVC insulation, wiring code 0
Normally ships in 2-3 Weeks
Call Today!
800-567-8686
Cable assembly, 6 conductor, PVC insulation, wiring code OUT
Normally ships in 2-3 Weeks
Call Today!
800-567-8686
Field Mountable M8 and M12 Connectors
Normally ships in 2-3 Weeks
Call Today!
800-567-8686


Your Recently Viewed Items...