Madgetech

OctThermoVault Data Logger

Eight channel thermally insulated, battery powered, oven temperature data logger able to withstand extreme temperatures


$2,361.00 CAD
Normally ships in 1-2 Weeks

 
  Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

This Data Logger Requires IFC200 USB Cable & Software Package.

The OctThermoVault is an eight channel thermally insulated, battery powered, oven temperature data logger able to withstand extreme temperatures. It can measure and record data of temperatures up to 350°C (662°F) for up to 25 min when properly sealed. Its stainless steel enclosure and thermal properties lend itself to be the ideal temperature recording device for applications such as powder coating cure ovens, wet coating cure ovens, batch ovens and conveyor ovens. The external thermocouple probes provide accurate temperature measurements, with fast response times.

Our user-friendly software easily downloads the data to a computer, where the readings may be displayed in degrees Celsius, degrees Fahrenheit, Kelvin or Rankine. The software allows the user to view all data points or a range of data points and a summary of the data being viewed for calculations such as Mean Kinetic Temperature (MKT). If additional analysis of the data needs to be performed, the data can be easily exported to Excel® by simply clicking a button.

One 72 in Type K thermocouples and one AC power supply are included.

• NIST traceable
• Programmable start time
• Reusable
• Convenient size
• User-friendly
• Automatic cold junction compensation
• Automatic thermocouple linearization
• Type K thermocouples and power supply included

Temperature

Channels

8 internal and 8 remote

Internal Channel

Temperature Sensor

Semiconductor

Temperature Range

-20°C - 60°C

Temperature Resolution

0.5°C (0.9°F)

Calibrated Accuracy

± 0.5°C (0°C - 50°C)

Remote Channel

Temperature Sensor

Thermocouple Types J, K, T, E, R, S, B ,N

Thermocouple Included

Type K, 72 in length

Temperature Range

Thermocouple Dependent

Temperature Resolution

Thermocouple Dependent

Calibrated Accuracy

Thermocouple Dependent

Thermocouple Connection

Female subminiature (SMP)

Thermocouple

 

 

 

Type

Range

Resolution

Accuracy

J

-210°C - 760°C

0.1°C

± 5°C

K

-260°C - 1370°C

0.1°C

± 5°C

T

-260°C - 400°C

0.1°C

± 5°C

E

-260°C - 980°C

0.1°C

± 5°C

R

-50°C - 1760°C

0.5°C

± 2°C

S

-50°C - 1760°C

0.5°C

± 2°C

B

60°C - 1820°C

0.5°C

± 2°C

N

-260°C - 1300°C

0.1°C

± 5°C

Cold Junction Compensation

Automatic based on internal channel

Maximum Exposure Time

Ambient Temperature

Maximum Duration

100°C (212°F)

110

150°C (302°F)

62

200°C (392°F)

45

250°C (482°F)

35

260°C (500°F)

33

300°C (572°F)

30

350°C (662°F)

25

General

Memory

500,000 readings per channel, channels can be disabled to increase memory

Reading Rate

4 readings every 1 s up to 1 reading every 24 hrs

Baud Rate

115,200

Start Modes

Software programmable immediate start or delay start up to six months in advance

Real Time Recording

May be used with PC to monitor and record data in real time

Calibration

Digital calibration through software

Calibration Date

Automatically recorded within device

Battery Type

9 V lithium or alkaline battery included; user replaceable

Battery Life

18 months typical

Data Format

Date and time stamped °C, °F, K, °R, µV, mV, V

Time Accuracy

± 1 min/month @ 20°C, RS232 port not in use

Computer Interface

USB (interface cable required), 115,200 baud

Software

XP SP3/Vista/Windows 7/Windows 8

Material

304 Stainless Steel with PTFE insulation

Weight

8.98 lb (4.07 kg)

Dimensions

Includes Handles, Brackets, and Front Enclosure Latches

12.3 in x 6.65 in x 2.45 in

(723 mm x 168 mm x 62 mm)

Enclosure Case Only, Excluding Handles, Brackets, and Latches

9.1 in x 5.9 in x 2.45 in

(231 mm x 149 mm x 62 mm)

Operating Environment

See Maximum Exposure Time, at 0% RH - 95% RH, Non-condensing

Internal OctTemp

-20°C - 55°C, 0% RH - 95% RH, Non-condensing

OctThermoVault System

-20°C - 350°C, 0% RH - 95% RH, Non-condensing

• Extreme temperature monitoring
• Oven profiling
• Powder coating cure ovens
• Wet coating cure ovens
• Batch ovens
• Conveyor ovens
• Implement HACCP programs

Item
Description
Availability
Price
IFC200 Data Logger Interface
USB interface cable package for standard series data loggers
Normally ships in 1-2 Weeks
$160.65 CAD
U9VL-J Lithium Battery
9.0 V, lithium battery, 1200 mAH
Normally ships in 1-2 Weeks
$21.00 CAD
MadgeTech 4 Secure Validation Software Package
IQ/OQ/PQ secure software validation workbook and software package
Normally ships in 1-2 Weeks
$1,890.00 CAD