Precision Digital

PD2-6001 Helios Feet & Inches Level Meter

Display will read up to 99 feet, 11 & 15/16s inches on the upper line, operate from -40 to 150F

Starting At
$1,524.00 CAD
Normally ships in 1-2 Weeks

Configure   Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

What sets the Helios apart from other Large Display Meters is its dual line display with super bright LEDs that can be read even in bright sunlight and up to 100 feet away. Based on Precision Digital's popular line of ProVu® digital panel meters, the Helios can satisfy a wide variety of level, flow, temperature, pressure, & weight applications. It is available with models that accept 4-20 mA, thermocouple, RTD, pulse, strain gauge, AC and DC volts and current, and even Modbus®.

Go with the Helios PD2-6001 when you prefer to read level in feet and inches instead of the more common decimal format. This unique display will read up to 99 feet, 11 & 15/16s inches on the upper line. The lower line can display a tag or volume, even from non-linear tanks such as round horizontal ones. The PD2-6001 makes a great outdoor tank side indicator because its display is bright enough to read in direct sunlight and it will operate from -40 to 150°F. The PD2-6001 can also be equipped with a 4-20 mA output as well as four relays that can be used for alarming or controlling applications, including pump alternation control.

Input


0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ±10 V


 

Helios Features

• Large 1.80" Digits
• Dual Line Display
• Six Full Digits on Each Line
• Readable From 100 Feet Away
• Superluminous Sunlight Readable Display
• IP65 Rated Field Mountable Enclosure
• Great for Outdoor Use: -40 to 150°F (-40 to 65°C)
• Program the Meter from a PC with Onboard USB and MeterView® Pro

PD2-6001 Features

• Feet & Inches Display Ideal for Level Applications
• Isolated 24 VDC @ 200 mA Transmitter Power Supply
• Multi-Pump Alternation Control
• Display a Single Input in Two Different Scales (e.g. Height & Volume)
• Signal Input Conditioning for Oddly Shaped and Round Horizontal Tanks
• 32-Point, Square Root, or Exponential Linearization
• Current Input Protected by Resettable Fuse
• Displays Fractions of an Inch as Eighths or Sixteenths

Display Two lines with 1.8" (46 mm) high digits with feet & Inches designations, red LEDs; 6 digits per line (-99999 to 999999), with lead zero blanking
Feet & Inches Display Range 0" 00" 0/16" to 99" 11" 15/16"
Display Intensity Eight intensity levels
Display Update Rate 5/second (200 ms)
Over Range Display flashes 999999
Under Range Display flashes -99999
Display Assignment The upper and lower displays may be assigned to PV1, PV2, PCT (percent), d r-u, d gross, d nt-g, max/min, alternate max & min, set points, units (lower display only), or Modbus input.
Programming Methods Four SafeTouch through-glass buttons when cover is installed. Four internal pushbuttons when cover is removed.
F4 Digital Input Contacts 3.3 VDC on contact. Connect normally open contacts across F4 to COM.
F4 Digital Input Logic Levels Logic High: 3 to 5 VDC; Logic Low: 0 to 1.25 VDC
Noise filter Programmable from 2 to 199 (0 will disable filter)
Filter Bypass Programmable from 0.1 to 99.9% of calibrated span
Recalibration Calibrated at the factory. Recalibration is recommended at least every 12 months.
Max/Min Display Max / min readings reached by the process are stored until reset by the user or until power to the meter is turned off.
Password Three programmable passwords restrict modification of programmed settings.
Non-Volatile Memory All programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost.
Power Options 85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max or 12-24 VDC 10%, 15 W max. Powered over USB for configuration only.
Isolated Transmitter Power Supply Terminals P+ & P-: 24 VDC 10%. 12-24 VDC powered models selectable for 24, 10, or 5 VDC supply (internal P+/P- switch). 85-265 VAC models rated @ 200 mA max, 12-24 VDC powered models rated @ 100 mA max, @ 50 mA max for 5 or 10 VDC supply.
Fuse Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse.
Isolation 4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply.
Overvoltage Category Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
Environmental T6 Class operating temperature range Ta = -40 to 60C
T5 Class operating temperature range Ta = -40 to 65C
See LIM8 ProtEX-MAX instruction manual for additional details.
Max Power Dissipation Maximum power dissipation limited to 15.1 W. See PD8 instruction manual for additional details.
Connections Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters.
Enclosure UL Type 4X, IP65 rated. Polycarbonate & glass blended plastic case, color: gray. Includes four PG11 through-hole conduit openings, with two factory installed PG11, IP68, black nylon threaded hole plugs with backing nuts
Wall Mounting Four (4) mounting holes provided for mounting meter to wall.
Pipe Mounting Optional pipe mounting kit (PDA6260) allows for pipe mounting. Sold separately.
See PD2-6001 manual for instructions.
Dimensions (H x W x D) 10.63" x 12.59" x 4.77" (270 mm x 319.7 mm x 121.2 mm)
Weight 6.10 lbs (2.76 kg)
UL File Number UL & C-UL Listed. E160849; 508 Industrial Control Equipment.
USB Connection Compatibility: USB 2.0 Standard, Compliant Connector Type: Micro-B receptacle Cable: USB A Male to Micro-B Cable Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit, Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit Power: USB Port
Warranty 3 years parts & labor

Item
Description
Availability
Price
MOD-PD2LRHB1 Red Light / Horn / Reset Button
A red light, horn and reset button mounted & wired to Helios
Normally ships in 1-2 Weeks
$420.00 CAD
PDA6260 Helios Pipe Mounting Kit
Helios pipe mounting kit zinc plated steel
Normally ships in 1-2 Weeks
$144.20 CAD
PDAPLUG2 Conduit Plug
Helios plastic conduit plug
Normally ships in 1-2 Weeks
$54.60 CAD
PDA0004 Cable Gland
Cable gland for Helios large display meter
Normally ships in 1-2 Weeks
$14.00 CAD