Precision Digital

PD2-6262 Helios Dual Analog Input Flow Rate/Totalizer

Displays two 4-20 mA flowmeter inputs on one meter and rate and total simultaneously, math functions

Starting At
$1,734.00 CAD
Normally ships in 1-2 Weeks

Configure   Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

What sets the Helios apart from other Large Display Meters is its dual line display with super bright LEDs that can be read even in bright sunlight. The dual line display simplifies programming and also makes it possible to display more information. For instance, the upper line can display the process variable and the lower line a tag or a different scale of the input. In a flow application, one line could display flow rate and the other line flow total. Even if you are not installing the Helios outdoors in bright sunlight, you will appreciate its big, clear, bright display that can be seen from up to distances of 100 feet (30 meters).

Go with the Helios PD2-6262 when you want to display two 4-20 mA flowmeter inputs on one meter. Both of these inputs can be displayed on six full digits and each flowmeter is provided with its own 24 VDC power supply. The PD2-6262 can also perform a variety of math functions on those two inputs, such as computing the difference between them or summing them together. One application for the PD6262 is determining fuel consumption by computing the difference between two flowmeter inputs.

Input


Two (2) 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ±10 V

Helios Features

• Large 1.80" Digits
• Dual Line Display
• Six Full Digits on Each Line
• Readable From 100 Feet Away
• Superluminous Sunlight Readable Display
• IP65 Rated Field Mountable Enclosure
• Great for Outdoor Use: -40 to 150°F (-40 to 65°C)
• Program the Meter from a PC with Onboard USB and MeterView® Pro

PD2-6262 Features


• Displays Two Flow Inputs Simultaneously
• Displays Rate and Total Simultaneously
• Math Functions Capabilities
• Isolated 24 VDC @ 200 mA Transmitter Power Supply
• Count Up or Down, Total & Grand Total
• Open Chanel Flow with Programmable Exponent
• Non-Resettable Grand Total
• 32-Point Linearization
• Current Input Protected by Resettable Fuse
• On-Board Digital Input (for Remote Reset)

Display Two lines with 1.8" (46 mm) high digits, red LEDs; 6 digits per line (-99999 to 999999), with lead zero blanking
Display Intensity Eight user selectable intensity levels
Display Update Rate 5/second (200 ms)
Over Range Display flashes 999999
Under Range Display flashes -99999
Display Assignment The Upper and Lower displays may be assigned to show: •One or more rate channels: Channel A (Ch-A), B (Ch-B), or C (Ch-C)
•Toggle between rate channels: Ch-A & Ch-B, Ch-A & Ch-C, Ch-B & Ch-C, and Ch-A, Ch-B, & Ch-C
•Total or grand total: Ch-A or Ch-B
•Rate and total or grand total: Ch-A, Ch-B
•Relay set points
•Max and/or min values: Ch-A, Ch-B, or Ch-C
•Toggle between any rate channel & units
•Total and units: Ch-A or Ch-B
•Toggle between totals: Ch-A & Ch-B; Ch-A, Ch-B, and sum of Ch-A and Ch-B
•Modbus input
The lower display may also be set to show engineering units or be off, with no display.
Programming Methods Four programming buttons, digital inputs, PC and MeterView Pro software, or Modbus registers.
Noise Filter Programmable from 2 to 199 (0 will disable filter)
Filter Bypass Programmable from 0.1 to 99.9% of calibrated span
Recalibration All ranges are calibrated at the factory. Recalibration is recommended at least every 12 months.
Max/Min Display Max/min readings reached by the process are stored until reset by the user or until power to the meter is turned off.
Password Three programmable passwords restrict modification of programmed settings.
Pass 1: Allows use of function keys and digital inputs
Pass 2: Allows use of function keys, digital inputs and editing set/reset points
Pass 3: Restricts all programming, function keys, and digital inputs.
Power Options 85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max or 12-24 VDC ± 10%, 15 W max. Powered over USB for configuration only. Isolated Transmitter Power Supply: Terminals P+ & P-: 24 VDC ± 10%. 12-24 VDC powered models selectable for 24, 10, or 5 VDC supply (internal P+/P- switch). 85-265 VAC models rated @ 200 mA max, 12-24 VDC powered models rated @ 100 mA max, @ 50 mA max for 5 or 10 VDC supply.
Non-Volatile Memory All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost.
Fuse Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse
Normal Mode Rejection Greater than 60 dB at 50/60 Hz Isolation: 4 kV input/output-to-power line; 500 V input-to-output or output-to-P+ supply
Overvoltage Category Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
Environmental Operating temperature range: -40 to 150°F (-40 to 65°C); Storage temperature range: -40 to 185°F (-40 to 85°C); Relative humidity: 0 to 90% non-condensing
Connections Removable and integrated screw terminal blocks accept 12 to 22 AWG wire.
Enclosure IP65 rated. Polycarbonate & glass blended plastic case, color: gray. Includes four PG11 through-hole conduit openings, with two factory installed PG11, IP68, black nylon threaded hole plugs with backing nuts.
Wall Mounting Four (4) mounting holes provided for mounting meter to wall.
Pipe Mounting Optional pipe mounting kit (PDA6260) allows for pipe mounting. Sold separately.
See PD2-6262 manual for instructions.
Tightening Torque Removable Screw Terminals: 5 lb-in (0.56 Nm); Digital I/O and RS485 Terminals: 2.2 lb-in (0.25 Nm)
Overall Dimensions (H x W x D) 10.63" x 12.59" x 4.77" (270 mm x 319.7 mm x 121.2 mm)
Weight 6.10 lbs (2.76 kg)
USB Connection Compatibility: USB 2.0 Standard, Compliant Connector Type: Micro-B receptacle Cable: USB A Male to Micro-B Cable Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit, Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit Power: USB Port
Warranty 3 years parts & labor

Item
Description
Availability
Price
PDA6260 Helios Pipe Mounting Kit
Helios pipe mounting kit zinc plated steel
Normally ships in 1-2 Weeks
$144.20 CAD
PDAPLUG2 Conduit Plug
Helios plastic conduit plug
Normally ships in 1-2 Weeks
$54.60 CAD
PDA0004 Cable Gland
Cable gland for Helios large display meter
Normally ships in 1-2 Weeks
$14.00 CAD