COVID-19 Update: Alpha Controls & Instrumentation is here to help and support your business in anyway possible during these uncertain times. Please click here to read more.

Precision Digital

PD2-6400 Helios High Voltage & Current Meter

Displays voltage and current on one large display meter, computes and displays apparent power

Starting At
$1,710.00 CAD
Normally ships in 1-2 Weeks

Configure   Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

What sets the Helios apart from other Large Display Meters is its dual line display with super bright LEDs that can be read even in bright sunlight and up to 100 feet away. Based on Precision Digital's popular line of ProVu® digital panel meters, the Helios can satisfy a wide variety of level, flow, temperature, pressure, & weight applications. It is available with models that accept 4-20 mA, thermocouple, RTD, pulse, strain gauge, AC and DC volts and current, and even Modbus®.

Go with the Helios PD2-6400 when you want to display voltage and current on one large display meter you can see from a distance. The PD2-6400 can even compute and display apparent power by multiplying the two inputs together.

Input

High Voltage: (Channel V) 0-300 VDC or VAC;
High Current: (Channel A) 0-5 AAC or ADC;
Both Switch Selectable.


 

 

Helios Features

• Large 1.80" Digits
• Dual Line Display
• Six Full Digits on Each Line
• Readable From 100 Feet Away
• Superluminous Sunlight Readable Display
• IP65 Rated Field Mountable Enclosure
• Great for Outdoor Use: -40 to 150°F (-40 to 65°C)
• Program the Meter from a PC with Onboard USB and MeterView® Pro

PD2-6400 Features


• Displays Voltage and Current Simultaneously
• Multiplication for Apparent Power Calculation
• Up to Three 4-20 mA Analog Outputs Available

Display Two lines with 1.8" (46 mm) high digits, red LEDs; 6 digits per line (-99999 to 999999), with lead zero blanking
Display Intensity Eight user selectable intensity levels
Display Update Rate 5/second (200 ms)
Over Range Display flashes 999999
Under Range Display flashes -99999
Display Assignment Displays lines 1 & 2 may be assigned to process values for Channels A (Ch-A, current), V (Ch-V, voltage), or P (Ch-P, apparent power); toggle between (Ch-A & Ch-V, Ch-A & Ch-P, Ch-V & Ch-P, and Ch-A, Ch-V, & Ch-P); relay set points; max and/or min values for CH-A, Ch-V, or Ch-P; CH-A and units; Ch-V and units; Ch-P and units; or Modbus input. The lower display may also be set to show engineering units or be off, with no display.
Programming Methods Four programming buttons, digital inputs, PC and MeterView Pro software, or Modbus registers.
Noise Filter Programmable from 2 to 199 (0 will disable filter)
Filter Bypass Programmable from 0.1 to 99.9% of calibrated span
Recalibration All ranges are calibrated at the factory. Recalibration is recommended at least every 12 months
Max/Min Display Max/min readings reached by the process are stored until reset by the user or until power to the meter is turned off.
Password Three programmable passwords restrict modification of programmed settings.
Pass 1: Allows use of function keys and digital inputs
Pass 2: Allows use of function keys, digital inputs and editing set/reset points
Pass 3: Restricts all programming, function keys, and digital inputs.
Power Options 85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max or 12-24 VDC 10%, 15 W max. Powered over USB for configuration only.
Non-Volatile Memory All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost.
Fuse Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse
Isolation 500 V AC/DC potential allowed between voltage and current input channels. Channels isolated by 3 MΩ impedance. 4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply.
Overvoltage Category Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
Environmental Operating temperature range: -40 to 150F (-40 to 65C); Storage temperature range: -40 to 185F (-40 to 85C); Relative humidity: 0 to 90% non-condensing
Connections Removable and integrated screw terminal blocks accept 12 to 22 AWG wire.
Enclosure UL Type 4X, IP65 rated. Polycarbonate & glass blended plastic case, color: gray. Includes four PG11 through-hole conduit openings, with two factory installed PG11, IP68, black nylon threaded hole plugs with backing nuts.
Wall Mounting Four (4) mounting holes provided for mounting meter to wall.
Pipe Mounting Optional pipe mounting kit (PDA6260) allows for pipe mounting. Sold separately.
See PD2-6400 manual for instructions.
Tightening Torque Removable Screw Terminals: 5 lb-in (0.56 Nm)
Digital I/O and RS485 Terminals 2.2 lb-in (0.25 Nm)
Overall Dimensions (H x W x D) 10.63" x 12.59" x 4.77" (270 mm x 319.7 mm x 121.2 mm)
Weight 6.10 lbs (2.76 kg)
UL File Number UL & C-UL Listed. E160849; 508 Industrial Control Equipment.
USB Connection Compatibility: USB 2.0 Standard, Compliant
Connector Type: Micro-B receptacle
Cable: USB A Male to Micro-B Cable
Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit, Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit
Power: USB Port
Warranty 3 years parts & labor

Item
Description
Availability
Price
MOD-PD2LRHB1 Red Light / Horn / Reset Button
A red light, horn and reset button mounted & wired to Helios
Normally ships in 1-2 Weeks
$450.00 CAD
PDA6260 Helios Pipe Mounting Kit
Helios pipe mounting kit zinc plated steel
Normally ships in 1-2 Weeks
$154.50 CAD
PDAPLUG2 Conduit Plug
Helios plastic conduit plug
Normally ships in 1-2 Weeks
$58.50 CAD
PDA0004 Cable Gland
Cable gland for Helios large display meter
Normally ships in 1-2 Weeks
$15.00 CAD