The Sabre T PD743 temperature meter combines operational simplicity with high end features to deliver the perfect low-cost digital panel meter for display only applications. The PD743’s menu structure is easy to navigate because the only selections are for input and temperature units; there are no other menu choices to add confusion during the setup process. Despite being a low-cost meter, the PD743 is still packed with many features typically found only on more expensive meters, such as a NEMA 4X front, universal power supply, display to 2300 °F for type K thermocouple, UL listing, and CE marking.

     

• J, K, T, E Thermocouple & 100 Ω Pt RTD
• Pre-Calibrated for All Input Types
• NEMA 4X, IP65 Front
• Shallow Depth 1/8 DIN Case 3.2" Behind Panel
• 4 Digit Display, 0.56" (14 mm) High, Red LEDs
• Easy Front Panel Programming
• Maximum/Minimum Display
• Universal Power Supply 85-265 VAC
• 12-36 VDC/12-24 VAC Power Option

Display 0.56" (14.2 mm) red LED, 4 digits (-1999 to 9999)
Front Panel NEMA 4X, IP65; panel gasket provided
Programming Methods Four front panel buttons
Display Update Rate RTD: 5/sec; TC: 2.5/sec
Over Range Display flashes 9999
Under Range Display flashes -1999
Recalibration All inputs are calibrated at the factory; recalibration is recommended at least every 12 months
Max/Min Display Stored until reset by user or meter is turned off
Password Restricts modification of programmed settings
Non-Volatile Memory Settings stored for a minimum of 10 years
Power Options 85-265 VAC, 50/60 Hz; 90-265 VDC, 8 W max or 12-36 VDC; 12-24 VAC, 6 W max
Required Fuse UL Recognized, 5 A max, slow-blow; up to 6 meters may share one fuse
Normal Mode Rejection 64 dB at 50/60 Hz
Isolation 4 kV input/output-to-power line
Operating Temperature 0 to 65C
Storage Temperature -40 to 85C
Relative Humidity 0 to 90%
Connections Power & Signal: removable screw terminal blocks accept 12 to 22 AWG. Note: RJ11 header for factory use only
Enclosure 1/8 DIN, high impact plastic, 94 V-0, color; gray
Weight 8.5 oz (241 g)
UL File Number E160849; 508 Industrial Control Equipment
Warranty 1 year parts & labor