The ProtEX-MAX™ PD8-6001 explosion-proof level indicator offers all the functionality of the ProVu PD6001 as a fully FM, CSA, ATEX, and IECEx approved explosion-proof product. It is specifically designed to display level in feet & inches, instead of the usual decimal format. The meter accepts a process current (4-20 mA) or process voltage (0-5V, 1-5V, etc.) signal and displays that signal on a dual-line display with convenient feet and inches designations on the upper line. The upper display can even read fractions of an inch in 8ths or 16ths. The lower line can be used to indicate a tag or to display the input in another scale, such as volume in gallons or liters. The PD8-6001 includes a 24 VDC power supply to drive the transmitter and can be equipped with up to four internal relays and a 4-20 mA output. It can be programmed and operated without opening the housing by using the built-in SafeTouch® through-glass buttons or the RS485 serial communication port with free Modbus® protocol.

               

Quick Overview

• Input: 0-20 mA, 4-20 mA; ±10 VDC (0-5, 1-5, 0-10 V); Modbus PV (slave)
• Display: Dual-line 6-digit, 0.60" (15 mm) Feet & Inches Upper Display & 0.46" (12 mm) Lower Display
• Enclosure: Smooth die-cast aluminum explosion-proof
• Input Power Options: 85-265 VAC or 12-24 VDC
• Operating Temperature Range: -40 to 65°C
 

• SunBright Display Standard
• Dual-scale for level applications - single input
• Isolated 24 VDC @ 200 mA transmitter power supply
• General purpose or round horizontal tank linearization
• Multi-pump alternation control
• SafeTouch® through-glass button programming
• Modbus RS-485 serial communications
• Built-in flanges for wall or pipe mounting
• Isolated 24 VDC @ 25 mA transmitter power supply
• Onboard USB and MeterView® Pro programming software

Display Upper feet & inches display: 0.60" (15 mm) high with feet & inches designations. Lower display: 0.46" (12 mm) high. Both are 6 digits (-99999 to 999999), red LEDs.
Feet & Inches Display Range 0" 00" 0/16" to 99" 11" 15/16"
Display Intensity Eight intensity levels
Display Update Rate 5/second (200 ms)
Over Range Display flashes 999999
Under Range Display flashes -99999
Display Assignment The upper and lower displays may be assigned to PV1, PV2, PCT (percent), max/min, alternate max & min, set points, units (lower display only), or Modbus input.
Front Panel NEMA 4X, IP65
Programming Methods Four through-glass SafeTouch buttons, four mechanical buttons behind glass, digital inputs, PC and MeterView Pro software, or Modbus registers.
F4 Digital Input Contacts 3.3 VDC on contact. Connect normally open contacts across F4 to COM.
F4 Digital Input Logic Levels Logic High: 3 to 5 VDC
Logic Low 0 to 1.25 VDC
Noise filter Programmable from 2 to 199 (0 will disable filter)
Filter Bypass Programmable from 0.1 to 99.9% of calibrated span
Recalibration Calibrated at the factory. Recalibration is recommended at least every 12 months.
Max/Min Display Max / min readings reached by the process are stored until reset by the user or until power to the meter is turned off.
Password Three programmable passwords restrict modification of programmed settings.
Non-Volatile Memory All programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost.
Input Power Options 85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max, or optional model with 12-24 VDC 10%, 15 W max.
Fuse Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse.
Isolated Transmitter Power Supply Terminals P+ & P-: 24 VDC 10%. Isolated from the input at >500 V. Jumper selectable for 24, 10, or 5 VDC supply (internal jumper J4). All models transmitter supply rated @ 25mA max.
Normal Mode Rejection Greater than 60 dB at 50/60 Hz
Isolation 4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply.
Overvoltage Category Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
Environmental T6 Class operating temperature range Ta = -40 to 60C
T5 Class operating temperature range Ta = -40 to 65C
Max Power Dissipation Maximum power dissipation limited to 15.1 W. See PD8 instruction manual for additional details.
Connections Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters.
Enclosure 1/8 DIN, high impact plastic, UL 94V-0, color: black
Mounting 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm). Two panel mounting bracket assemblies are provided.
Tightening Torque Screw terminal connectors: 5 lb-in (0.56 Nm)
Dimensions (H x W x D) 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm)
Weight 9.5 oz (269 g)
UL File Number UL & C-UL Listed. E160849; 508 Industrial Control Equipment.
USB Connection Compatibility: USB 2.0 Standard, Compliant
Connector Type: Micro-B receptacle
Cable: USB A Male to Micro-B Cable
Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit,
Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit
Power: USB Port
Warranty 3 years parts&labor

Item
Description
Availability
Price
PDA0001 Reducer for the PD68XX
3/4" M-NPT to F-M20 Reducer for the PD68XX
Normally ships in 1-2 Weeks
$35.00 CAD
PDA0002 Reducer for the PD68XX
3/4" M-NPT to 1/2" F-NPT Approved Reducer for the PD68XX
Normally ships in 1-2 Weeks
$35.00 CAD
PDA6846 Pipe Mounting Kit
Pipe mounting kit for ProtEX
Normally ships in 1-2 Weeks
Starting At
$14.00 CAD
Configure