The ProtEX-MAXTM PD8-6100 offers all the functionality of the ProVu PD6100 as a fully FM, CSA, ATEX, and IECEx approved explosion-proof product. It accepts strain gauge & load cell inputs and mV signals up to 300 mV (unipolar) and ± 250 mV (bipolar) for weight and force measurement applications. The PD8-6100 strain gauge meter's dual-line display and powerful dual-scale capability allows the measurement to be displayed in two different units of measure. Another use for the PD8-6100's dual-lines is to simply display the units of measure on the bottom line. SafeTouch® through-glass buttons allow for access to zero, tare, and other functions without the need to remove the enclosure cover. The PD8-6100 includes a 24 VDC power supply to drive the sensors and can be equipped with up to four internal relays and two 4-20 mA outputs.

                    

Quick Overview

• Input: 0-10, 0-20, ±10, ±20, ±100, ±200 mV; Modbus PV (slave)
• Display: Dual-line 6-digit, 0.60" (15 mm) & 0.46" (12 mm)
• Case: Smooth die-cast aluminum explosion-proof
• Power: 85-265 VAC or 12-24 VDC option
• Operating Temperature: -40 to 65°C
 

• SunBright Display Standard
• Selectable 5 or 10 VDC excitation power supply
• Capture or programmable tare feature
• Ratiometric operation
• Dual-scale feature - single input
• Rounding function 1, 2, 5, 10, 20, 50, or 100
• Auto-zero feature eliminates zero drift
• SafeTouch® through-glass button programming
• Modbus RS-485 serial communications
• Flanges for wall or pipe mounting
• Isolated 24 VDC @ 25 mA transmitter power supply
• Onboard USB and MeterView® Pro programming software

Display Upper display: 0.60" (15 mm) high. Lower display: 0.46" (12 mm) high. Both are 6 digits (-99999 to 999999), red LEDs.
Display Intensity Eight intensity levels
Display Update Rate 5/second (200 ms)
Over Range Display flashes 999999
Under Range Display flashes -99999
Display Assignment The upper and lower displays may be assigned to PV1, PV2, PCT (percent), max/min, alternate max & min, set points, units (lower display only), or Modbus input.
Programming Methods Four through-glass SafeTouch buttons, four mechanical buttons behind glass, digital inputs, PC and MeterView Pro software, or Modbus registers.
F4 Digital Input Contacts 3.3 VDC on contact. Connect normally open contacts across F4 to COM.
F4 Digital Input Logic Levels Logic High: 3 to 5 VDC; Logic Low: 0 to 1.25 VDC
Noise filter Programmable from 2 to 199 (0 will disable filter)
Filter Bypass Programmable from 0.1 to 99.9% of calibrated span
Recalibration Calibrated at the factory. Recalibration is recommended at least every 12 months.
Max/Min Display Max / min readings reached by the process are stored until reset by the user or until power to the meter is turned off.
Password Three programmable passwords restrict modification of programmed settings.
Non-Volatile Memory All programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost.
Input Power Options 85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max, or optional model with 12-24 VDC 10%, 15 W max.
Fuse Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse.
Normal Mode Rejection Greater than 60 dB at 50/60 Hz
Isolation 4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply.
Overvoltage Category Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
Environmental T6 Class operating temperature range Ta = -40 to 60C
T5 Class operating temperature range Ta = -40 to 65C
Max Power Dissipation Maximum power dissipation limited to 15.1 W. See PD8 instruction manual for additional details.
Connections Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters.
Enclosure Explosion-proof die cast aluminum with glass window, corrosion resistant epoxy coating, color: blue. NEMA 4X, 7, & 9, IP68. Default conduit connections: Four " NPT threaded conduit openings and two " NPT metal conduit plugs with 12 mm hex key fitting installed. Additional conduit opening configurations may be available; verify quantity and sizes on specific device labeling during installation.
Mounting Four slotted flanges for wall mounting or NPS 1" to 2" or DN 40 to 65 mm pipe mounting
Dimensions (W x H x D) 6.42" x 7.97" x 8.47" (163 mm x 202 mm x 215 mm)
Weight 16.0 lbs (7.26 kg)
USB Connection Compatibility: USB 2.0 Standard, Compliant
Connector Type: Micro-B receptacle
Cable: USB A Male to Micro-B Cable
Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit,
Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit
Power: USB Port
Warranty 3 years parts & labor

Item
Description
Availability
Price
PDA0001 Reducer for the PD68XX
3/4" M-NPT to F-M20 Reducer for the PD68XX
Normally ships in 1-2 Weeks
$37.50 CAD
PDA0002 Reducer for the PD68XX
3/4" M-NPT to 1/2" F-NPT Approved Reducer for the PD68XX
Normally ships in 1-2 Weeks
$37.50 CAD
PDA6846 Pipe Mounting Kit
Pipe mounting kit for ProtEX
Normally ships in 1-2 Weeks
Starting At
$15.00 CAD
Configure