Precision Digital

PD9000 ConsoliDator+ Multivariable Controller

Accepts 4-20 mA inputs, flow meter pulse inputs, digital inputs, and Modbus RTU inputs and displays them both in numeric and bargraph format on a large, 5.7" color display

Starting At
$2,848.00 CAD
Normally ships in 1-2 Weeks

Configure   Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

The ConsoliDator+ is a multi-channel controller that is both easy to use and satisfies a wide variety of process display, alarm and control applications. It accepts 4-20 mA inputs, flow meter pulse inputs, digital inputs, and Modbus RTU inputs and displays them both in numeric and bargraph format on a large, 5.7" color display. It can be equipped with multiple relays with user-definable actions, 4-20 mA outputs, digital outputs, Modbus RTU, and Ethernet Modbus TCP/IP protocol communication capabilities. Additionally, the controller is equipped with up to 32 timers that can be used to control many processes or events.

All this functionality is easily programmed using free software or via the front panel pushbuttons. Choose the model that best suits your application, from monitoring only to fully loaded controllers with an extensive combination of inputs, outputs and communication protocols. The standard product offering is listed in the ordering guide and other models are available for special order.

• NEMA 4X Panel or Field Mount Multi-Channel Controller
• Convenient Display, Control, & Alarm of Multiple 4-20 mA & Pulse Inputs
• Numeric & Bargraph Color Display (320 x 240 pixels) 5.7" (145 mm)
• Sunlight Readable Display, White Backlight
• Isolated 24 VDC Transmitter Supplies 200 mA / Analog Input; 1,600 mA Max
• 99 Channels, 32 Totalizers, 32 Timers, & 199 Modbus Slave Inputs
• 64 High & Low Alarms assigned to up to 25 Relays with AND/OR Logic
• Modular Design for Input & Output Flexibility
• Up to (28) 4-20 mA Isolated Inputs or Pulse Inputs
• Up to (25) 10 Amp Form C Relays (With Eight Analog or Pulse Inputs)
• Up to (25) Isolated 4-20 mA Outputs (With Eight Analog or Pulse Inputs)
• Pulse, Analog, & Modbus Input Flow Rate / Total / Grand Total Capabili
• 50-Point Linearization, Square Root, and Exponent for Open Channel Fl
• Round Horizontal Tank Volume Calculation; Just Enter Diameter & Length
• Multi-Pump Alternation Control or Simple On / Off Control
• Programmable Displays, Function Keys & Digital Inputs
• Math Functions: Sum, Diff, Average, Multiply, Divide, % Efficiency, & More
• Display Direct Modbus PV Inputs – Slave Mode
• RS-485 Modbus RTU Standard & Ethernet Modbus TCP/IP Optional
• Free ConsoliDator+ Configuration Software

Display Color; QVGA (320x240 px), 5.7" (145 mm) diagonally, white backlight Bargraph: Twenty divisions Numerical: Up to 15 digits (999,999,999,999,999) Feet & Inches Format: 99,999' 11.9"
Screen Bargraph Enable/disable: Channels, totals, timers Bargraph scale: 0 100%, independent of channel scale. Twenty divisions: 5% each. Screen: Select to show bargraph or not.
Decimal Point 0 to 15 decimal places, user selectable
Engineering Units User selectable units or custom units Time, Distance, Volume, Pressure, Weight, Temperature, Current, Voltage, Percent, Amps, Volts, Counts, Logic, and Custom, Any unit/unit of time or other units
Display Update Rate User selectable: 0.1 to 10 sec (10 updates/sec to 1 update/10 sec)
Programming Method Front panel buttons, external buttons, or ConsoliDator+ Software
Number of Alarms Up to 64 high or low Automatic (non-latching) or latching On & Off time delays. May be assigned to one or more relays. Note: Alarms are independent from relays.
Alarm Types Single Source: One input
Multi-Source: Two or more inputs
Interval: Enter time interval and On Time
Alarm OR: Any active input alarm triggers the OR alarm
Alarm AND: All input alarms must be active to trigger the AND alarm
Alarm Ack & Reset Automatic only (Non-latching)
Automatic and manual
Manual only (Latching)
Manual with Ack only after alarm is cleared (Latching with Clear)
Internal Buzzer 60 dBA @ 24 inches (61 cm) Enable/disable in System General menu. Associated with alarm Horn setting
External Horn (Sold separately) Assign any relay to the Horn function to activate an external horn when alarm condition is detected.
Input & Output Cards Max Number of I/O Cards: 7, Analog Inputs: 4/card, Pulse Inputs: 4/card, Analog Outputs: 5/card, Relays: 5/card
Number of Screens Up to 20 screens with 1 to 8 PVs or items per screen. Enable or disable screen title, channel #, and bargraph Automatic or manual scanning Scan time: 1 to >1000 sec, independent for each screen. F1-F4 keys are assigned per screen
Function Keys User programmable (See defaults below) F1 = Previous ← F2 = Next → F3 = Scan/Stop F4 = Ack
Number of Channels Up to 99 channels, Input source: 4-20 mA, Pulse, Digital, Modbus, Alarm, or Math
Password Programmable password restricts modification of programmed settings
Non-Volatile Memory Settings stored for a minimum of 10 years
Power (User Selectable Based on Wiring) Three-terminal connector (L, N, GND), AC: 80-264 VAC, 47 to 63 Hz, 60 W max DC: 113-370 VDC, 60 W max (L, N), Two-terminal connector (G, 24V) DC: 24 VDC 10%, 60 W max
Backup Power Supply If AC and DC power are connected, the 24 VDC can be used as backup power in case of AC power failure.
Fuse Unit is protected internally with auto-resettable fuse. AC: 1.25 A max, DC: 3.7 A max
External Fuse Recommended external fuse slow-blow 120 VAC: 2.0 A, 240 VAC: 1.0 A, 24 VDC: 4 A
Isolation & Grounding 1500 V Analog inputs/outputs-to-power line
500 V Analog input-to-input, input-to-output, analog output-to-output
All analog inputs and analog outputs are isolated from each other.
Note: DC Power is not isolated. DC- is connected to Earth Ground. Digital I/O, USB, and Ethernet are grounded.
Environmental Operating temperature range: -40 to 60C (-40 to 140F)
Storage temperature range: -40 to 60C (-40 to 140F)
Relative humidity: 0 to 90% non-condensing
*All functions operate down to -40C (-40F.) If the LCD response is slower, increase the display refresh setting.
Connections Removable screw terminal blocks, Inputs/Outputs: 12 to 24 AWG wire, Digital I/O: 16 to 30 AWG, RS-485: 12 to 24 AWG wire RJ45 Ethernet connection. USB ports: Micro-USB (Device) and Type A (Host)
Tightening Torque Screw terminal connectors: 5 lb-in (0.56 Nm)
Digital I/O terminals: 2.5 lb-in (0.28 Nm)
Enclosure Enclosure Body: Thermoplastic Polyester, Color: Gray, Display Window: Clear Polycarbonate, GE LEXAN HP12W, Front Panel Keys: Silicone rubber
Tamper Proof Enclosure The field mount enclosure's cover is secured by a clasp that can be locked to prevent unauthorized access to the enclosure's interior.
Mounting: Wall-Mount Four screws/bolts required (not provided)
Pipe-Mount: (2) U-Bolts for 2" Pipe (See Ordering Information)
Panel-Mount: Panel-mounting frame and twelve screws (provided)
Cutout: 10.0" x 10.0" 0.05" (254 mm x 254 mm 1.3 mm) (H x W)
Panel thickness: 0.07" 0.35" (1.8 mm 8.9 mm)
Clearance behind panel: 6" (152 mm)
Conduit Connections There are four center punched marks on each side of the field enclosure. Holes must be drilled by the installer according to the desired conduit entry. Size: " or " (16 mm or 21 mm),
Clearance: 1.5" (38 mm) diameter
Overall Dimensions Panel-Mount: 10.85" x 10.85" x 4.87" (276 mm x 276 mm x 124 mm) (H x W x D)
Field-Mount: 11.5" x 12.0" x 8.03" (292 mm x 305 mm x 204 mm) (H x W x D)
Weight Ex: PD9000-XY-4PI-8AI-10AO-10RY
Panel-Mount: 7.4 lb (3.4 kg) approx.
Field-Mount: 10.8 lb (4.9 kg) approx.
Warranty 3 years parts and labor