The Process101A Data Logger measures and records low level DC current and is available in three different measurement ranges, 20 mA, ± 160 mA and ± 3 A. This device is ideal for many process driven, general purpose current recording applications including battery or photovoltaic studies.

All of the ranges offer a 10 year battery life, 4 Hz reading rate, programmable or pushbutton start/stop and a 1 million reading storage capacity with optional memory wrap. These features allow for long term active logging deployment and low maintenance. As with many of MadgeTech’s 101A series of data loggers, the screw terminal block is designed to easily connect and disconnect to the logger body to simplify retrieval of the device for downloading data by keeping the wiring to the terminal block in place. Other features of the Process101A include a battery life indicator, optional password protection, programmable high-low alarms and more.

Using the MadgeTech Software makes configuring the data logger and  downloading data simple and user friendly. Graphical, tabular and summary data format options are provided for analysis and data can be viewed in A, mA or μA. The data can also be exported to Excel® for further customized reporting or calculations.

• 10 year battery life
• 4 Hz reading rate
• Multiple Start/Stop function
• Ultra high speed download
• 1 million reading storage capacity
• Memory wrap
• Battery life indicator
• Optional password protection
• Programmable high and low alarms
• Field upgradeable

Current

Nominal Range

20 mA

± 160 mA

± 3 A

Measurement Range

- 2 mA - 30 mA

± 160 mA

± 3 A

Maximum Voltage Between Inputs to Ground

0 V - 2.5 V

Resolution

0.5 µA

5 µA

100 µA

Calibrated Accuracy

± 0.05% FSR

± 0.15% FSR

Input Impedance

10 Ω, ± 1%

1 Ω, ± 1%

< 0.05 Ω

Absolute Maximum Current

316 mA

1 A

1 A

Input Connection

Removable screw terminal

General

Analog Conversion Time

133 ms nominal

Frequency Rejection

50 Hz - 60 Hz

Temperature Coefficient

< ± 50ppm/°C typical

Reading Rate

4 Hz to 1 reading every 24 hrs

Memory

1,000,000 readings; software configurable memory wrap

333,000 readings in multiple start/stop mode

Wrap Around

Yes

Start Modes

Immediate start

Delay start up to 18 months

Multiple pushbutton start/stop

Stop Modes

Manual through software

Timed (specific date and time)

Multiple Start/Stop Mode

Start and stop the device multiple times without having to download data or communicate with a PC

Multiple Start/Stop Mode Activation

To start the device:

Press and hold the pushbutton for 5 s. The device has started logging.

To stop the device:

Press and hold the pushbutton for 5 seconds, the red LED will flash for 3 s and then the green LED will flash for 2 s. The device has stopped.

Real Time Recording

The device may be used with PC to monitor and record data in real time**

Alarm

Programmable high and low limits; alarm is activated when current reaches or exceeds set limits

LED Functionality

Green LED blinks:

10 s rate to indicate logging, 15 second rate to indicate delay start mode

Red LED blinks:

10 s rate to indicate low battery and/or full memory

Password Protection

An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password

Engineering Units

Native measurement units can be scaled to display measurement units of another type. This is useful when monitoring voltage outputs from different types of sensors such as temperature, CO2, flow rate and more

Calibration

Digital calibration through software

Calibration Date

Automatically recorded within device

Battery Type

3.6 V lithium battery included; user replaceable

Battery Life

10 year battery life typical, at a 15 min reading rate

Data Format

Date and time stamped current, engineering units specified through software

Time Accuracy

± 1 min/month (stand alone data logging)

Computer Interface

USB (interface cable required); 115,200 baud

Software

XP SP3/Vista/Windows 7/Windows8

Operating Environment

-40 °C to +80 °C (-40 °F to +176 °F), 0 %RH to 95 %RH non-condensing

Dimensions

1.4 in x 2.2 in x 0.6 in (36 mm x 56 mm x 16 mm)

Weight

0.9 oz (24 g)

Materials

ABS plastic

Approvals

CE

• 4 mA - 20 mA recording
• pH recording
• Low level DC current monitoring
• Photovoltaic studies
• Battery studies
• General purpose current recording

Item
Description
Availability
Price
MadgeTech 4 Secure Validation Software Package
IQ/OQ/PQ secure software validation workbook and software package
Normally ships in 1-2 Weeks
$1,890.00 CAD
IFC200 Data Logger Interface
USB interface cable package for standard series data loggers
Normally ships in 1-2 Weeks
$160.65 CAD
LTC-7PN Lithium Battery
3.6 V, lithium battery, 750 mAH
Normally ships in 1-2 Weeks
$14.00 CAD
Waterbox101A
Weatherproof enclosure designed for use with MadgeTech's 101A series data loggers
Normally ships in 1-2 Weeks
$47.25 CAD
Terminal Block
Pluggable terminal block for use with MadgeTech data loggers
Normally ships in 1-2 Weeks
Starting At
$4.05 CAD
Configure