Madgetech

RFVolt2000A Wireless Data Logger

Wireless, differential voltage data logger, equipped with a three position terminal block to allow for a positive, negative and ground connection

Starting At
$444.00 CAD
Normally ships in 2-3 Weeks

Configure   Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

The RFVolt2000A is a wireless data logger designed to measure and record DC voltage signals. The data logger can connect directly to DC voltage sources, making it ideal for battery usage studies, solar energy monitoring and other DC voltage monitoring applications. The RFVolt2000A can also be interfaced with a wide range of voltage output sensors, including pressure sensors and CO2 sensors, as well as transmitters and other transducers. The RFVolt2000A is available in a 2.5 V, 15 V, 30 V or 160 mV measurement range.

The RFVolt2000A-160mV model is a wireless, differential voltage data logger. The device is equipped with a three position terminal block to allow for a positive, negative and ground connection. This allows the measurement of the voltage difference between two signals tied to the same ground.

The LCD screen on the RFVolt2000A provides instant access to the current reading, as well as minimum, maximum and average statistics. Using the MadgeTech software, the device can be programmed to record in engineering units, which convert the voltage signals into a different unit of measure such as PSI, % or ppm. The statistics can be reset through the keypad of the device without erasing collected data, allowing customers to keep track of statistics over varying time periods.

The RFVolt2000A can be used as a standalone data logger, or used with the RFC1000 wireless transceiver, to transmit data back to the central PC. The RFVolt2000A can transmit up to 500 ft (line of sight) to the RFC1000 transceiver.  However, multiple RFC1000's can be set up and used as repeaters, capable of transmitting data up to 1000 ft (line of sight) to other RFC1000's. This allows the data to be sent over a greater distance.

The RFVolt2000A is compatible with the latest MadgeTech 4 Software. After downloading, the data can be viewed in graphical or tabular formats. Summary and statistic views are also available for further analysis as well as the ability to be exported to Excel®.

• Battery lfe indicator
• Digital display
• Direct USB interface
• AC power connection via USB
• Configurable alarms
• Ability to manually reset statistics
• 5 year battery life at 15 min reading rate
• 160 mV model measures differential voltage

Measurement

Measurement Range

2.5 V

3 VDC - 3 VDC 

15 V

-8 VDC - 24 VDC 

30 V

-8 VDC - 32 VDC 

160 mV

-160 mVDC - 160 mVDC

Measurement Resolution

0 - 2.5 VDC

0.1 mVDC 

0 - 15 VDC

0.5 mVDC 

0 - 30 VDC

1.0 mVDC 

0 - 160 mVDC

5 μv

Calibrated Accuracy

2.5 V

± 0.05% FSR at 25°C (77°F) 

15 V

± 0.05% FSR at 25°C (77°F)

30 V

± 0.05% FSR at 25°C (77°F) 

160 mV

± 0.01% FSR at 25°C (77°F)

Response Time

150 ms at sensor

Wireless

RF Frequency

32,256 Readings

Band

1 reading every 1 s up to 1 reading every 24 hrs

Transceiver Sensitivity (RFC1000)

250,000

Transmission Distance (to Data Loggers)

Green, Blue & Red

Transmission Distance (To Other RFC1000s)

5 years typical at a 15 min reading rate

Material

ABS plastic

Dimensions (Data Logger Only)

3.5 in x 3.17 in x 0.95 in (88.9 mm x 80.5 mm x 24.1 mm)

General

Memory

32,256 Readings

Reading Rate

1 reading every 1 s up to 1 reading every 24 hrs

Baud Rate

250,000

LED Indicators

Green, Blue & Red

Battery Life

5 years typical at a 15 min reading rate

Material

ABS plastic

Dimensions (Data Logger Only)

3.5 in x 3.17 in x 0.95 in (88.9 mm x 80.5 mm x 24.1 mm)

IP Rating

IP22

Operating Environment

-20°C - 60°C (-4°F - 140 °F), 0% RH - 95% RH, Non-condensing

Required Interface Package

RFC1000 (wireless); USB to Mini USB Cable

Approvals

US (FCC), CA (IC), CE,

South Korea (KCC), China (CMIIT), Japan (LCIE)

• Battery usage studies
• Solar cell monitoring
• Cathodic protection monitoring
• Pressure monitoring
• CO2 monitoring
• 160 mV model measures radio or electromagnetic frequency interference

Item
Description
Availability
Price
U9VL-J Lithium Battery
9.0 V, lithium battery, 1200 mAH
Normally ships in 1-2 Weeks
$21.00 CAD
RFC1000 Wireless Transceiver
Wireless transceiver for the RFOT, Therm-A-Lert and RF2000A series of data loggers
Normally ships in 1-2 Weeks
$268.65 CAD
RFC1000-CE Wireless Transceiver
Powerful wireless receiver for use with the RFOT, Therm-A-lert and RF2000A Series of data loggers, CE approved, includes an external antenna
Normally ships in 1-2 Weeks
$268.65 CAD
RFC1000-IP69K Splashproof Transceiver
Splash proof wireless transceiver for the RFOT, Therm-A-Lert and RF2000A series of data loggers
Normally ships in 1-2 Weeks
$403.65 CAD
USB Universal Power Adapter
Universal multiblade USB power adapter for the IFC406, RFC1000, RFC1000-CE, VTMS, and RF2000A
Normally ships in 1-2 Weeks
$37.80 CAD
MadgeTech 4 Secure Validation Software Package
IQ/OQ/PQ secure software validation workbook and software package
Normally ships in 1-2 Weeks
$1,890.00 CAD