` S8000 Chilled Mirror Hygrometer

Michell Instruments

S8000 Chilled Mirror Hygrometer

High-precision hygrometer combines straightforward operation w/ very high sensitivity to changes in moisture content

Starting At
$24,289.00 CAD
Normally ships in 12+ Weeks

Configure   Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

The S8000 precision hygrometer provides a direct measurement of dew point, temperature and pressure. Suitable for both industrial and laboratory applications, the instrument is compact and self-contained.
 
Dew-point measurement is based on the proven, fundamental optical chilled mirror measurement principle, giving long-term reliable humidity measurement over the entire operating range. The S8000 uses this measurement to offer a range of available measurement units including ppmV, absolute humidity, relative humidity and ppmW.

• ±0.1°Cdp (±0.18°Fdp) accuracy
• Fundamental, accurate and drift-free measurement
• Simple configuration and operation via touch screen interface
• Precision measurements to –60°C (–76°F) dew point
• FAST – guaranteed frost formation below 0°C (+32°C)
• Measure at pressures up to 2 MPa (20 barg)
• USB, Ethernet, RS485 or RS232 connectivity
• Datalogging to SD card or via digital comms

Dew-Point Sensor Performance
Measurement Technology Chilled Mirror
Accuracy ±0.1°Cdp
Reproducibility ±0.05°C
Measurement Range –60 to +40°Cdp (–76 to +104°Fdp)
Operating Pressure Low pressure version: 0 to 1 barg / 14.5 psig
High pressure version: 0 to 20 barg / 290 psig
Sample Flow Rate 0.1 to l Nl/min (0.2 to 2.1 scfh)
Detection System RRS Triple Detection
Remote PRT Probe (Optional)
Temperature Measurement 4 wire Pt100, 1/10 DIN class B
Measurement Accuracy ±0.1°C
Cable Length 2m (6.6') (250m (820') max)
Flow Sensor
Measurement Accuracy Typical ±5% uncalibrated
Measurement Range 0 to 1000 ml/min
Integrated Pressure Sensor (Optional)
Measurement Range 0 to 25 bara (0 to 377 psia)
Measurement Accuracy 0.25% Full Scale
Measurement Units psia, bara, KPa or MPag
Monitors
Resolution User-selectable to 0.001 dependant on parameter
Measurement Units °C and °F for dew point and temperature %RH, g/m3, g/kg, ppmV , ppmW (SF6), for calculated humidities
Outputs Analog 3 channels, user selectable 4-20 mA, 0-20 mA or 0-1 V
Digital Modbus RTU over USB, and optional Modbus RTU over RS232, RS485 or Modbus TCP over Ethernet
Alarm Two volt-free changeover contacts, one process alarm, one fault alarm; 1 A @ 30 V DC
HMI 5.7” LCD with touchscreen, white on blue graphics
Data Logging SD Card (512Mb supplied) and USB interface
SD Card (FAT-16) — 2Gb max. that allows 24 million logs or 560 days, logging at 2 second intervals
Environmental Conditions –20 to +40°C (–4 to +104°F)
Power Supply 85 to 264 V AC, 47/63 Hz
Power Consumption 100 V A
EMC - Class A Emissions Industrial Location Immunity Complies with EN61236:1997 (+A1/A2/A3)
Mechanical Specifications
Dimensions 187 x 440 x 343mm (7.36 x 17.32 x 13.5”) h x w x d
Weight 11.4kg (25.1lb)
General
Process Connections 6mm Swagelok® (MALE)
tube or 1/4” Swagelok® tube (MALE)
Storage Temperature –20 to +50°C (–40 to +122°F)
Calibration 3-point traceable in-house calibration as standard
UKAS accredited calibrations optional - please consult Michell

 • Standards laboratory reference instrument

• Transformer vacuum drying verification
• Clean/dry room environmental monitoring
• Metallurgical process monitoring
• Reference instrument for commercial calibration laboratory
• Compressed air dryer R&D
• SF6 switchgear moisture testing
• Hydrogen fuel cell R&D