SA1100 Diaphragm Operated Pressure Switches

Weatherproof and explosion-proof, burst pressure protection to 3000 PSI, visible set-point and deadband adjustments

Starting at
$1,003.35CAD
Have questions? We're here to help!
Have questions? We're here to help!
Configure

The Series SA1100 Diaphragm Operated Pressure Switches are weatherproof and explosion-proof in one economical enclosure. Extremely rugged construction assures excellent reliability in chemical, petroleum and industrial plants. New design also provides burst pressure protection to 3000 PSI (206 Bar). The rolling diaphragm design maintains a constant effective area to minimize friction. This results in a minimum deadband as low as 5% of full-scale. Since many applications require higher deadbands, the SA1100 includes a separate adjustment of this when necessary. A pump being used to control liquid level in a tank would be a typical situation where this feature would be important. Both setpoint and deadband adjustments are protected, yet clearly visible behind a clear polycarbonate window and are fully isolated from the electrical components for additional safety. A 7/16 in open-end wrench is the only tool required to change settings. Terminal blocks are provided for switch wiring connections and both internal and external ground screws are included. Standard housing is weatherproof to NEMA standards 1 through 4X and 13; explosion-proof to NEMA 7, Class I, Groups B, C & D; NEMA 9, Class II, Groups E, F & G. Optional construction adds drain to meet NEMA 3R IP54.

• Explosion-proof and weatherproof housing provides device protection for outdoor use or harsh environment operation
• Burst pressure protection prevents device failure where high-pressure surges may damage device costing down-time and repair/replacement
• Adjustable deadband reduces equipment cycling and potential failure
• Visible set-point and deadband adjustments provide an easy and fast check without having to open device causing dangerous conditions to operators
 

Wetted MaterialsSee pressure chamber and diaphragm material in model chart
Temperature Limits-30°F - 180°F (-35°C - 82°C) standard.
ATEX compliant at Ambient Temperature -4°F - 167°F (-20°C - 75°C);
Process Temperature: -4°F - 167°F (-20°C - 75°C)
Pressure Limit1200 PSIG (82.6 Bar)
Enclosure RatingWeatherproof and Explosion-proof. Listed with UL and CSA for Class I, Groups B, C and D; Class II Groups E, F and G. ATEX Compliant CE 0344 Ex II 2 G EEx d IIC T6 Process Temperature 75°C. Weatherproof UL Rated Type 4. Meets NEMA 4X (IP66)
Switch TypeSPDT or DPDT snap switch
Electrical RatingSee model chart
Electrical ConnectionsScrew terminal
Conduit Connection3/4 in female NPT
Process Connection1/2 in female NPT
Mounting OrientationWithin 20° of vertical
Set Point AdjustmentInternal 7/16 in hex nuts
Weight3.5 lb (1.6 kg)
DeadbandSee deadband chart
Agency ApprovalsATEX, CE, CSA, UL

• Chemical, petroleum, food and drug processing industries
• Used indoor, outdoor or in explosion-proof area
• Pump control
 

  • Thumbnail of document Manual - SA1100 Diaphragm Operated Pressure Switches
    Download

    Manual - SA1100 Diaphragm Operated Pressure Switches

    Download
  • Thumbnail of document Data Sheet - SA1100 Diaphragm Operated Pressure Switches
    Download

    Data Sheet - SA1100 Diaphragm Operated Pressure Switches

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more