The Edgetech Instruments SENTRY turn-key measurement and alarm system features a smart multi-sense probe that continuously monitors the dew/frost point and pressure of compressed air systems to detect compressor or dryer failures and system pressure leaks.The SENTRY features a strobe lamp and pulsing horn plus an alarm relay contact that activate when a programmable, low pressure or high dew/frost point alarm trip point is detected. Either condition triggers the alarms. It also has a local display of the measured pressure and dew/frost point of the compressed air system plus 4 to 20 mA analog outputs, one each for measured pressure and dew/frost point at atmospheric pressure. The SENTRY is a complete system, ready for out-of-the-box installation.All Edgetech Instruments dew/frost point monitors are manufactured and supported in the USA in a modern, ISO 9001:2015 registered facility with ISO/IEC 17025:2017 accredited calibration laboratory.
Models: | |
SENTRY 85: | Provides Strobe Lamp and 85dB pulsing Audible Alarm when High Dew Point or Low Pressure condition exists |
SENTRY 100: | Provides Strobe Lamp and 100dB pulsing Audible Alarm when High Dew Point or Low Pressure condition exists |
Measuring Range (HPP125 Sensor Probe): | |
Standard Dew Point: | -40°C to +95°C (-40°F to 203°F ) |
LDP Dew Point: | -60°C to +95°C (-76°F to 203°F ) |
Pressure: | Up to 400psig (0 to 27.6bar) |
Accuracy: | |
Dew Point: | ±1°C for –10°C to 95°C DP and ±2°C for –60°C to –10°C |
Pressure: | ±1 mbar @ 25°C (600 to 1200 mbar) / ±5mbar (-40°C to +125°C) |
General: | |
Enclosure: | IP65 Water Resistant/ Dust Tight, approximately 5”(127mm) x 5” (127mm) x 4” H (102mm) |
Weight: | 3 Lbs. (1.4 kg) |
Display: | 2 Line LCD display of Pressure and Pressure Dew Point, LED Backlit Smart Sensor Probe is connected to SENTRY control module via 1 meter long signal cable, quick connect |
Operating Temperature: | 32° to 122°F (0° to 50°C) |
Sample Connection: | 1/2” Male NPT Pipe Fitting; optional 3/4” or 1” Male NPT Pipe Fitting |
Sample Pressure: | Up to 400psig (27.6 bar) |
Power & Outputs: | |
Power: | 90-230 VAC ±10%, 50-400Hz , 3 meter length power cord provided |
Analog Outputs: | (2) 4-20 mA outputs Pressure of compressed air at sensor probe, PSIA Pressure Dew Point, calculated for 1 ATM Relay Alarm, 1 Form C, 3A @250 VAC ; Alarm mode = Low Pressure or High Dew Point. |
Accessories: | |
CAM: | Sample chamber for probe; Provides sample flow to sensor probe and includes a ball valve to isolate the probe from the pressurized source during service 3/4 inch NPT Female pipe threaded port to compressed air system take-off point |
View All Part Numbers