We're the complete package when it comes to providing
THE FULL CALIBRATION EXPERIENCE
ALPHA SERVICES
We offer service to the following calibration disciplines:
Our Metrologists have the highest level of accreditation and use only state-of-the-art technology from the proven leaders in calibration instrumentation, including Fluke Calibration, Thunder Scientific, Fluke Electronics, and DH Instruments. We are an ISO 9001 registered company and our calibration services are accredited to ISO/IEC 17025 by the American Association for Laboratory Accreditation (A2LA), one of the most stringent accreditation authorities that is accepted worldwide*.
ALPHA IS ABLE TO PROVIDE
• Fully trained Metrologists
• Full calibration and service support
• Standard calibration procedures for all calibrations performed
• MET/CAL Calibration Management Software
• NIST traceable reports
• A2LA Accreditation to ISO/IEC 17025 (scope # 2260.01)*
• ISO 9001:2015 registration for all our quality management processes
• Reference standards with accuracies that suit all your calibration needs
HOW AN A2LA ACCREDITATION BENEFITS YOU
• Staff are fully qualified, properly trained, and experienced
• Calibration and testing of equipment is performed in suitable testing facilities
• Proper handling, sampling, and transportation of test items
• Quality assurance of calibration data and procedures
• Perform proper sampling practices and test methods
• Provides accurate recording and reporting procedures
• Provides confidence in the measurement results
• Minimizes risk to the customer
ALPHA CALIBRATION CAPABILITIES
HUMIDITY
• Humidity:
10% - 95% RH, ± 0.5% RH
• Dew Point Temperature:
-90°C — 30°C, ± 0.1°C
• Ambient Temperature:
-30°C — 60°C, ± 0.1°C
TEMPERATURE
• Range:
196°C — 660°C, ± 0.01°C
660°C — 1200°C, ± 2.3°C
• Infrared:
-15°C — 500°C, ± 0.5°C
• Fixed Points:
LN2, Hg, TPW, Sn, Zn, Al
FLOW
• 0.1 SLM — 100 SLM
• 0 SCCM — 100 SCCM
• 100 SLM — 250 SLM
GAS
• Methane, Oxygen, Hydrogen Sulfide, Propane,
R 507, CO, CO2, Pentane, Nitrogen, and more
PARTICLES
• Sizes:
0.1 µm — 25 µm, ± 5%
ANALYTICAL
• Conductivity • Time
• pH • Tachometers
ELECTRICAL
• Voltage:
1000 V AC/DC
• Current:
1000 A AC/DC
• Resistance
0 GΩ — 2 GΩ
• Capacitance
0.19 nF — 110 mF
• RTD / TC
Pt100, J, K, T, and more
• Frequency
0 MHz — 225 MHz
PRESSURE
• Gauge / Absolute:
0 — 1000 PSIG / PSIA, ± 0.009% RDG
• Differential:
-60 — 60 in W.C., ± 0.00015 in W.C.
• Barometric
750 — 1150 mbar, ± 0.11 mbar
• Vacuum
0—30 in Hg, ± 0.003 in Hg
• Hydraulic
200 — 20,000 PSIG, ± 0.025% RDG
WHY CALIBRATE?
Instrument error can occur due to a variety of factors such as drift, environment, electrical supply, addition of components to the output loop, and process changes. Let our Metrologists ensure that your instrument is providing an accurate measurement. Get a quote for an accredited calibration today!
*Gas and Analytical calibrations are NIST only