The LogTag TICT is a single trip low cost electronic temperature indicator intended for monitoring temperature and time statistics during the transportation and storage of chilled or frozen products.

The LogTag Temperature Indicator can run up to 45 days storing statistics and monitoring four pre-set temperature Alarms.

 

• Clear indication of alarm status at all times.
• Monitor for up to 45 days.
• Push button Start and Stop.
• Records temperature from -25C to +60C.
 

Sensor Measurement Range -25°C to +60°C (-13°F to +140°F)
Operating Temperature Range -25°C to +60°C (-13°F to +140°F)
Storage Temperature Range 0°C to +40°C (32°F to +104°F)
Rated Temperature Reading Accuracy Better than ±0.5°C for -10°C to +25°C
Better than ±1.0°C for -25°C to -10°C
Better than ±1.0°C for +25°C to +60°C
Rated Temperature Reading Resolution 0.1°C for -20°C to +60°C
Sensor Reaction Time Typically less than 7 minutes (T90) in moving air (1m/s)
Recording Capacity Minimum & maximum temperature for each of the 45 days
1st activation of each alarm for each day including trigger time and duration of each event
Please note the TICT does not store each individual temperature reading taken
Sampling Interval Factory pre-set between 1 and 59 minutes; 5 minute interval for profile 0001
Logging Start Options Push button start. Factory pre-set between 1 and 255 minutes; 60 minute delay for profile 0001
Recording Indication OK ✔ = Temperature has remained within the alarm limits
Reject X = Alarm event has been generated
Alarm Events Four factory pre-set alarm events, two over temperature and two under temperature
Each alarm event can be instant reject or accumulative reject. It can also be disabled
Environmental IP64
Power Source 3V Li-Mg Battery
Battery Life Minimum storage life of 18 months before ‘start'
Monitoring period: 45 days
Minimum accessibility (display) period of 6 months after ‘stop'
Real Time Clock Built-in real time clock
Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day)
Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C)
Size 71.5mm(W) x 33.0mm(H) x 8.6mm(T)
Weight 23g
Case Material Polycarbonate