Smart Powered Strain Bridge/Load Cell Conditioner
The TXDIN1600S is a “smart” powered bridge amplifier for use with strain gauges or load cell signals. The product has a built-in capability to scale the input signal to a process value while the output stage offers either voltage, bipolar voltage or active/passive current re-transmission signals.
Bridge Input | |
Full Range | -7.6 to 7.6 mV/V (-38 to 38) mV at 5V excitation |
Type | Four wire radiometric |
Drift | < ± 0.05% |
Linearity | ± 0.01% |
Update | Selectable, 10 or 80 SPS (samples per second) |
Bridge Excitation | |
Voltage | 5 Volts DC ± 0.1 V @ 59 mA |
Bridge Impedance | Total 85 to 10000 Ω (operates with four 350 Ω cell in parallel) |
Tare Input | |
Type | Remote volt free contact, up to 10 meter distance |
Output Current | |
Current Source | Range (0 to 21.5) mA, max load 750 Ω |
Current Sink | Range 0 to 21.5 mA, supply 10 to 30 Vdc, voltage effect 0.2 uA/V |
Accuracy | (mA out/2000) or 5 uA whichever is the greater, drift 1 uA/°C |
Output Voltage | |
Range | 0 to 10.1 V or -10.1 to 10.1 V, accuracy ± 5 mV |
Current Drive | ± 2 mA, min load 5000 Ω @ 10 V |
Push Button Configuration | |
Type | Independent “Low” “High” front panel push buttons allow user to manuallyset low and high output points |
Supply | |
Range | 10 to 48 Vdc, 10 to 32 Vac protected by internal 500 mA resettable fuse |
Power | < 1 W full power |
General | |
Isolation | Supply to input to output 500 Vdc |
Indication | LED, green when output -0.1 to 100.1%, all else red |
User Interface | |
Type | USB 2.0 |
Baud rate | 19,200 baud |
Equipment | PC running Windows XP or later, USB cable. |
User Interface Functions | |
Calibration Scaling | (2 to 6) points signal against process |
Filter | (1 to 20) seconds to reach 70% of final value |
Tare | Remote set tare offset with programmable user set point |
Active Calibration | Active calibration against live load cell |
Process units | 4 characters |
Tag Number | 20 characters |
Process Output | Process output range |
Signal Output | Select type, signal range |
Active Scaling Output | Set output process range against active sensor input |
Sensor Information | Model, sensitivity and balance |
Environment | |
Operating Ambient | -30 to 70°C (-22 to 158ºF); 10 to 90%RH (non condensing) |
Storage Ambient | -30 to 70°C (-22 to 158ºF); 10 to 90%RH (non condensing) |
Configuration Ambient | 10 to 30°C (50 to 86ºF) |
Installation Enclosure | DIN rail enclosure offering Protection ≥ IP65 |
Approvals | |
CE | BS EN 61326 |
Mechanical | |
Style | DIN 43880, color grey, material Polyimide 6.6 |
Weight | < 70 g |
Terminals | 2.5 mm (0.10") maximum |
OMEGA TXDIN1600S DIN Rail Strain Gage/ Load Cell Transmitter w/Bipolar mA/V Output - Data sheet 811.2 KB |