Skip to main content
Press Enter
Starting at $5,741.26CAD
Configure
Dwyer

UFM2 Compact Ultrasonic Flowmeters

Economical, clamp-on, ultrasonic flowmeters

Starting at
$5,741.26CAD
Have questions? We're here to help!
Have questions? We're here to help!
Configure
The Series UFM2 Compact Ultrasonic Flowmeters are economical, clamp-on, ultrasonic flowmeters. The UFM2 implements the transit-time difference to measure flow rates in pipes and can measure velocity and flow in pipes with outside diameters ranging from 3/4 to 7" (25 to 180 mm). This model comes with a volume pulse and 4-20 mA flow rate output.
 
KIT INCLUDES:
• Converter with adjustable guide rail
• Set of pipe clamps (model dependent)
• Set of small pipe adapter circle clamps
• Set of small pipe adapter V clamps
• Ultrasonic coupling grease
• Save on installation costs with non-invasive pipe measurement
• Simplified installation with all necessary components included, such as converter, sensor, cables and mounting accessories
• Fit application requirements with compact and lightweight design, that can be easily installed, all in one clamp-on unit intended for homogeneous liquids that contain no air
• Cut down evaluation time with easy-to-read text displaying both flow rate and total with a convenient backlight for visual comfort
Pipe Wall Thickness:0.02 to 0.39" (0.5 to 10 mm).
Applicable Pipe Lining:None.
Pipe Outside Diameter:3/4 to 7" (25 to 180 mm). Pipe size is dependent on pipe material and internal diameter.
Applicable Pipe Material:Steel, copper, or plastic.
ADDITIONAL SPECIFICATIONS
Agency Approvals:CE.
Weight:2.9 lb (1.315 kg).
Response Time:<1 s.
Electrical Connections:16.4' (5 m) cable.
Repeatability:±0.15% of measured value.
Enclosure Material:Plastic polycarbonate.
Enclosure Rating:IP54.
Outputs:Analog: 1 opto-isolated: 4-20 mA; Error current: 3.5 mA; Load resistance: 620 Ω max; Pulse: 1 optoisolated MOSFET relay, 500 mA max, 166 pps max, 200 Hz max.
Temperature Limits:Process: 32 to 185°F (0 to 85°C); Ambient: 32 to 122°F (0 to 50°C).
Power Consumption:7 W max.
Power Requirements:12-24 VDC/VAC.
Accuracy:±3% of flow reading for >0.98 ft/s (>0.3 m/s).
Display:Backlit: 3.27" H x 0.74" W (83.1 mm x 18.8 mm), 2 line x 16 characters.
Range:0.33 to 32.8 ft/s (0.1 to 10 m/s).
Service:Clean water with <3% by volume of particulate content.
• Flow measurement for heat metering
• Metering and monitoring in: Chilled water, Potable water, Process water
  • Thumbnail of document Data Sheet - UFM2 Compact Ultrasonic Flowmeters
    Download

    Data Sheet - UFM2 Compact Ultrasonic Flowmeters

    Download
  • Thumbnail of document Manual - UFM2 Compact Ultrasonic Flowmeters
    Download

    Manual - UFM2 Compact Ultrasonic Flowmeters

    Download

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more