Input | 4/20 mA + HART, 2-wire / V = 9-32 VDC |
LCD Display | Available with LCD display (standard) or without LCD display (optional) |
Accuracy | 0.1% URL standard |
Stability | 0.2% of URL for two years |
Temperature Ranges | Working/Media temperature: -25/95°C (with display -13/203°F), -40/185°C (without display -4/158°F) Ambient temperature: -40/60°C (with display -40/140°F), -40/115°C (without display -4/240°F) Storage temperature: -40/110°C (with display -40/85°F), -40/230°C (without display -40/446°F) |
Working Humidity | 0-100% relative humidity |
Pressure Connection | 1/2” NPT M or F, G1/2”, M20*1.5 |
Housing | 304SS, 316SS, Rugged die-cast aluminum housing (painted Blue) |
Wetted Parts | 316 SS process connection, 316 L diaphragm |
Response Time | 200ms |
Turn on Time | 2 seconds (with minimum damping enabled) |
Power Consumption | <162.8 mW |
VIbration Effect | +/- 0.005% of URL per G to 200 Hz, in accordance to IEC60770-1:1999 |
Available Pressure Units | kPa, Mpa, bar, psi, mmHg, mmH2O, mH2O, inH2O, ftH2O, inHg, mHg, TORR, mbar, g/cm2, kg/cm2, Pa, ATM, m, cm, mm |
Protection Class | EMC, reverse polarity protected |
Approval | ATEX, II 2 G Ex db IIC T6 Gb ATEX, II 1 G Ex ia IIC T1~T6 Ga Intrinsically safe parameters: Ui=28Vdc, Ii=93mA, Pi=0.65W, Ci=5nF, Li=0 mH |
Protection Class | IP66 |
Weight | 5.95 lbs (2.7 kg) |
Operational Life | 100 million cycles |
• Suitable for pressure measurement in Oil & Gas installations (onshore and offshore), power generation, including renewable energy facilities, wastewater locations and many other hazardous areas.
Winters WINSMART LY14 - Data sheet 216.6 KB |
Winters WINSMART LY14 - Manual 865 KB |