Designed to expand oscilloscope applications in industrial and power environments
The Fluke i1000s is a clamp-on AC current probe designed to expand oscilloscope applications in industrial and power environments. Ideal for measuring distorted current waveforms and harmonics.
This current probe allows accurate measurement of currents from 100 mA - 1000 Arms, 5 Hz - 100 kHz without breaking into the circuit. A passive filter eliminates noise and ring on rapidly rising di/dt waveform, ensuring accurate screen displays. Connects directly to an oscilloscope through a reinforced coaxial cable and an insulated BNC connector. Can be used with Multimeters with optional PM9081/001 BNC/Banana adapter. One year warranty.
Specifications | ||
Current Range | Nominal | 10 A 100 A 1000 A |
Continuous | 0.1 A - 10 A 0.1 A - 100 A 1 A - 1000 A | |
Maximum Non-Destructive Current | 2000 A | |
Lowest Measurable Current | 0.1 | |
Basic Accuracy | 1% + 1 A (48 Hz - 65 Hz) (% reading + floorspec) | |
Useable Frequency | 5 Hz - 100 kHz | |
Output Level(s) | 100 mV/A 10 mV/A 1 mV/A | |
Safety Specifications | ||
Safety | CAT III 600 V / CAT IV 300 V | |
Maximum Voltage | 600 V AC | |
Mechanical & General Specifications | ||
Warranty | 1 year | |
Maximum Conductor Diameter | 54 mm | |
Output Cable Length | 1.6 m | |
BNC Adapter | Yes | |
| Fluke i1000s AC Current Probe - Manual 490.9 KB |