The i2000 is an AC current probe utilizing the Rogowski principle. It can be used to measure currents up to 2000A when used in conjunction with multimeters, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

The current clamp has three (3) ranges of 20A, 200 A & 2000 A, 100 mV/A, 10 mV/A & 1 mV/A output. Ideal for current measurement on thick and hard to reach conductors without breaking the circuit.  Maximum conductor diameter 178 mm. CAT III 600V safety rating.

Electrical Specifications

Current Ranges

20 A

200 A

2000 A

ACrms

Output Sensitivity (AC-Coupled)

100 mV

10 mV

1 mV

1 mV per A

Load Impedance

100 kΩ min.

Accuracy

At 25°C, +/- 1% of range (45 Hz - 65 Hz)

Linearity

10% - 100 % of range, +/- 0.2% of reading

Noise

8 mV ACrms (30 A)

2 mV ACrms (300 A, 3000 A)

Frequency Range

10 Hz - 20 kHz (-3 dB)

Phase Error

< +/- 1°C (45 Hz - 65 Hz)

+/- 10° (at 20 kHz)

Position Sensitivity

With cable > 25 mm from the coupling

+/- 2% of range

External Field

With cable > 200 mm from the head

+/- 1% of range

Power Supply

2 x AA/MN 1500/LR6 alkaline, 200 h, low battery indicator

Temperature Coefficient

+/- 0.08% of reading per °C

Working Voltage (see “Safety Standards” Section)

600 V ACrms or DC

 

General Specifications

Head Circumference

610 mm (24 in)

Head Cable Diameter

14.3 mm (0.56 in)

Head Bend Radius

38.1 mm (1.5 in)

Cable Length (Head to Electronics)

2 m (6.56 ft)

Output Connection

Molded 4 mm safety plugs (not integrated)

Storage Temperature

Operating

0°C - 70°C (32°F - 158°F) (head and electronics)

 

Storage

-40°C - 105°C (-40°F - 221°F) (head)

-20°C - 85°C (-4°F - 185°F) (electronics

Operating Humidity

15% - 85%, Non-condensing

Weight

180 g (6.34 oz) (head)

190 g (6.70 oz) (electronics)

Safety Standards

EN 61010-1:2001

EN 61010-2-032: 2002

EN 61010-031: 2002

600 Vrms, CAT III, Pollution Degree 2

Use of the probe on uninsulated conductors is limited to 600 V ACrms to DC and frequencies below 1 kHz

EMC Standards

EN 61326: 1998 +A1, A2, & A3

Dimensions (H x W x D)

116 mm x 68.5 mm x 30 mm (4.56 in x 2.69 in x 1.18 in)