Used to measure currents up to 2000 A when used in conjunction with multimeters, recorders or data loggers
The i2000 is an AC current probe utilizing the Rogowski principle. It can be used to measure currents up to 2000A when used in conjunction with multimeters, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.
The current clamp has three (3) ranges of 20A, 200 A & 2000 A, 100 mV/A, 10 mV/A & 1 mV/A output. Ideal for current measurement on thick and hard to reach conductors without breaking the circuit. Maximum conductor diameter 178 mm. CAT III 600V safety rating.
Electrical Specifications | ||
Current Ranges | 20 A 200 A 2000 A ACrms | |
Output Sensitivity (AC-Coupled) | 100 mV 10 mV 1 mV 1 mV per A | |
Load Impedance | 100 kΩ min. | |
Accuracy | At 25°C, +/- 1% of range (45 Hz - 65 Hz) | |
Linearity | 10% - 100 % of range, +/- 0.2% of reading | |
Noise | 8 mV ACrms (30 A) 2 mV ACrms (300 A, 3000 A) | |
Frequency Range | 10 Hz - 20 kHz (-3 dB) | |
Phase Error | < +/- 1°C (45 Hz - 65 Hz) +/- 10° (at 20 kHz) | |
Position Sensitivity | With cable > 25 mm from the coupling | +/- 2% of range |
External Field | With cable > 200 mm from the head | +/- 1% of range |
Power Supply | 2 x AA/MN 1500/LR6 alkaline, 200 h, low battery indicator | |
Temperature Coefficient | +/- 0.08% of reading per °C | |
Working Voltage (see “Safety Standards” Section) | 600 V ACrms or DC | |
General Specifications | ||
Head Circumference | 610 mm (24 in) | |
Head Cable Diameter | 14.3 mm (0.56 in) | |
Head Bend Radius | 38.1 mm (1.5 in) | |
Cable Length (Head to Electronics) | 2 m (6.56 ft) | |
Output Connection | Molded 4 mm safety plugs (not integrated) | |
Storage Temperature | Operating | 0°C - 70°C (32°F - 158°F) (head and electronics) |
Storage | -40°C - 105°C (-40°F - 221°F) (head) -20°C - 85°C (-4°F - 185°F) (electronics | |
Operating Humidity | 15% - 85%, Non-condensing | |
Weight | 180 g (6.34 oz) (head) 190 g (6.70 oz) (electronics) | |
Safety Standards | EN 61010-1:2001 EN 61010-2-032: 2002 EN 61010-031: 2002 600 Vrms, CAT III, Pollution Degree 2 Use of the probe on uninsulated conductors is limited to 600 V ACrms to DC and frequencies below 1 kHz | |
EMC Standards | EN 61326: 1998 +A1, A2, & A3 | |
Dimensions (H x W x D) | 116 mm x 68.5 mm x 30 mm (4.56 in x 2.69 in x 1.18 in) | |
| Fluke i2000-FLEX AC Current Clamp - Instructions 758 KB |