May be used in conjunction with oscilloscopes and other suitable recording instruments for accurate non-intrusive AC and DC current measurement
The i30s current clamp is based on Hall Effect technology for use in measurement of both DC and AC current. The i30s may be used in conjunction with oscilloscopes and other suitable recording instruments for accurate non-intrusive current measurement.
Electrical Specifications | ||
Current Range | Specified | 30 mA - 30 A DC 30 mA -20 A ACrms |
Useable | 5 mA - 30 A DC 30 mA - 20 A ACrms | |
Crest Factor | 1.4° | |
Output Sensitivity | 100 mV/A | |
Accuracy (at 25°C) | +/- 1% of reading +/- 2 mA | |
Resolution | +/- 1 mA | |
Load Impedance | > 100 kΩ | |
Conductor Position Sensitivity | +/- 1% relative to centre reading | |
Frequency Range | DC to 100 kHz (- 0.5 dB) | |
Phase Shift Below 1 kHz | < 2° | |
Temperature Coefficient | +/- 0.01% of reading /°C | |
Power Supply | 9 V alkaline, MN1604/PP3, 30 h, low battery indicator | |
Working Voltage (see “Safety Standards” Section) | 300 V ACrms or DC | |
General Specifications | ||
Maximum Conductor Size | 19 mm diameter | |
Output Connection | Safety BNC connector, supplied with safety 4 mm diameter | |
Output Zero | Manual adjust via thumbwheel | |
Cable Length | 2 m | |
Temperature Range | Operating | 0°C - 50°C |
Storage | -20°C - 85°C (with battery removed) | |
Operating Humidity | 15% - 85%, Non-condensing | |
Weight | 250 g | |
Safety | IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 300 V | |
Use of the probe on uninsulated conductors is limited to 300 V ACrms or DC and frequencies below 1 kHz | ||
EMC Compatibility | IEC 61326-1: Portable Electromagnetic Environment | |
| Fluke i30s AC/DC Current Clamp - Instructions 132.8 KB |