` i6000S Flex AC Current Probe

Fluke

i6000S Flex AC Current Probe

Can be used to measure currents up to 6000A when used in conjunction with oscilloscopes, recorders or data loggers

Starting At
$1,513.00 CAD
Normally ships in 4-6 Weeks

Configure   Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

The i6000sFlex is an AC current probe utilising the Rogowski principle. It can be used to measure currents up to 6000 A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

Two head cable lengths available, 24 in. and 36 in.

Electrical Characteristics

Current Ranges

 

 60 A / 600 A / 6000 A ACRMS

Output Sensitivity (AC Coupled)

 

 50 mV /5 mV / 0.5 mV per A

Load Impedance

 

 100 kΩ minimum

Accuracy (at 25°C)

 

 +/- 1% of range (45 Hz - 65 Hz)

Linearity (10% - 100% of Range)

 

 +/- 0.2% of reading

Noise

 

 8 mV ACRMS (60 A)

 

 2 mV ACRMS (600 A / 6000A)

Frequency Range

 

 10 Hz - 50 kHz (- 3 dB)

Phase Error

 

 < +/-1° (45 Hz – 65 Hz),

 

 +/- 10° (at 20 kHz)

Position Sensitivity (with Cable > 25 mm From The Coupling)

 

 +/- 2% of range

External Field (with Cable > 200 mm From The Head)

 

 +/- 1% of range

Power Supply

 

 2 x AA MN 1500 LR6 alkaline

 

 400 h, low battery indicator or dedicated ext power supply

Temperature Coefficient

 

 +/- 0.08% of reading per °C

Working Voltage (see “Safety Standards” Section)

 

 600 V ACRMS or DC

General Characteristics

Head Cable Length (Double Insulated)

i6000s Flex-24

24 in (610 mm)

i6000s Flex-36

36 in (915 mm)

Head Cable Diameter

 

14.3 mm

Head Bend Radius

 

38.1 mm

Cable Length (Head to Electronics)

 

2 m

Output Connection

 

0.5 m cable terminated with safety BNC connector
Supplied with 4mm safety plug adaptor

Temperature

Operating

-20°C - 90°C (head)

-20°C - 85°C (electronics)

Storage

-40°C - 105°C (head)

-20°C - 85°C (electronics)

Operating Humidity

 

15% - 85% (non condensing)

Weight

 

180 g (head),

190 g (electronics)

Safety Standards

BS EN 61010

 

 1: 2001

BS EN 61010

 

 2-032: 2002

BS EN 61010

 

 031: 2002

600VRMS, Category III, Pollution Degree 2

 

 

Note

 

Use of the probe on uninsulated conductors is limited to 600 V ACRMS or DC and frequencies below 1 kHz.

EMC Standards

BS EN 61326:

 1998 +A1, A2, & A3

       



Your Recently Viewed Items...