Designed for noisy production facilities, 7” LCD touchscreen overlays on a visual image for quick leak location identification
• Do more with the same air compressors – delay the capital expense of purchasing an additional compressor
• Ensure proper air pressure to your pneumatic equipment
• Lower utility costs
• Reduce leak detection time
• Improve reliability in your production line
Standard Palettes | 3: Grayscale, Ironbow, Blue-Red |
Operating Temperature | 0 °C to 35 °C (32 °F to 95 °F) |
Storage Temperature | -20 °C to 70 °C (-4 °F to 158 °F) |
Relative Humidity | 10 % to 95 % non-condensing |
Size (H x W x L) | 186 mm x 322 mm x 68 mm |
Weight (Battery Included) | 1.7 kg (3.75 pounds) |
Main Unit Rating | IP40 protection against particles 1mm or greater and dripping water |
Sensor Head Rating | IP51 |
Warranty | 2 year |
Self-Diagnostic Notification | Array-health test to identify when microphone array needs attention |
Supported Languages | Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese |
RoHS Compliant | Yes |
Safety | |
General Safety | IEC 61010-1 |
Electromagnetic Compatibility (EMC) International | IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2 CISPR 11: Group 1, Class A |
Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication) |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 |
Battery | |
Batteries (Field-Replaceable, Rechargeable) | Rechargeable Li-ion, Fluke BP291 |
Battery Life | 6 hours (product includes spare battery) |
Battery Charging Time | 3 hours |
Battery Charging System | External dual-bay charger, EDBC 290 |
Software | |
Ease of Use | Intuitive user interface |
Trend Graphs | Frequency and dB scale |
Spot Markers | dB level reading at center point of the image |
Acoustic Measurements | |
Measurement Range | 29.7 dB to 120 dB SPL at 2kHz 16 dB to 106.3 dB SPL (± 1 dB) at 19 kHz 21.4 dB to 117 dB SPL (± 1 dB) at 52 kHz |
Auto Max/Min DB Gain | Auto or manual, user selectable |
Frequency Band Selection | User selectable through user-made presets or manual entry |
Image Storage | |
Storage Capacity | Internal memory with the capacity for 999 picture files or 20 video files |
Image Format | Blended visual and SoundMap™.JPG or .PNG |
Video Format | Blended visual and SoundMap™.MP4 |
Video Length | 30 seconds |
Digital Export | USB-C for data transfer |
Display | 7" LCD with backlight, under-sunlight readable |
Resolution | 1280 x 800 (1,024,000 pixels) |
Touchscreen | Capacitive |
Acoustic Image | Yes, SoundMap™ image |
Built-In Digital Camera (Visible Light) | |
Field of View (FOV) | 63 ° ± 5 ° |
Focus | Fixed lens |
Sensors | |
Number of Microphones | 64 digital MEMS microphones |
Frequency Band | 2 kHz to 52 kHz |
Sound Pressure Sensitivity | Detects a 0.005 CFM leak at 100PSI from up to 32.8 feet (Detects a 2.5 cm3/sec leak at 7 bar from up to 10 meters) |
Operation Distance Range | 0.5 to > 50 meters (1.6 to > 164 feet) |
Field of View | 63 ° ± 5 ° |
Minimum Frame Rate | 12.5 FPS |
Fluke ii900 Sonic Industrial Imager - Data sheet 1.1 MB |