The stainless steel probe and digital readout are fixed together and calibrated as a system. The accuracy specification is easy to understand since it includes all uncertainty components, including drift, for up to one year. The large backlit LCD display rotates 90° degrees making it easy to read from any angle. A user-configurable stability/trend indicator lets you know when your temperature is stable enough to record an accurate measurement. A user-settable auto-off function extends typical battery life to three hundred hours. A low-battery indicator and stop-measure function prevent erroneous measurements from being made due to low battery life. A simple three-point calibration function allows you to easily and accurately calibrate the “Stik" Thermometer. Data logging to internal memory of up to 10,000 time-stamped measurements is optionally available.
 
Why calibrate process temperature sensors?
 
Because temperature greatly effects the accuracy of a volumetric measurement, process manufacturers of chemical, pharmaceutical, food or petroleum products require accurate temperature measurements—especially for processes where quality or custody transfer are regulated by government agencies. Since all temperature sensors are subject to drift with time, regular calibration or verification against a reliable reference thermometer is required. Finding a reference thermometer that is accurate, repeatable and robust, however, can be challenging.
 
What’s wrong with my reference thermometer?
 
Industrial reference thermometers available on the market today, such as mercury-in-glass thermometers (or “ASTM thermometers") and portable electronic thermometers are useful, but both come with inherent problems. Although accurate and repeatable, mercury thermometers are fragile. The risk of a mercury spill poses potential hazards to the environment and to the health of personnel. Many of the United States and European Union countries have already banned their use in industrial applications. Some organizations have replaced their mercury thermometers with more durable portable electronic thermometers, only to discover that the RTD probes lack the repeatability and dependability required of a legitimate reference thermometer.
 
The best alternative to mercury thermometers
 
The Fluke 1551A and Fluke 1552A “Stik" Thermometers are accurate, stable and durable, making it the best alternative to mercury thermometers and existing electronic thermometers. The thin-film RTD sensor incorporates the same characteristics of other premium reference thermometers designed by Fluke Calibration, but it is more robust and less susceptible to drift. Accuracy and repeatability, however, are not sacrificed for improved durability.
 
Using a glass-stem mercury- or spirit-filled thermometer at different immersion depths, or at significantly different ambient temperatures from which it was calibrated, may require the application of emergent-stem corrections that can be tedious but necessary to calculate an accurate measurement. This isn’t required with the “Stik" Thermometer. The sensor of the 1551A Ex requires a minimum immersion depth of only seven centimeters (2.8 inches), with no appreciable effect on the measured temperature due to heat loss through stem conduction. Some digital thermometers can become less accurate when used outside a narrow range of ambient temperatures. This isn’t the case for the “Stik" Thermometer. Your measurement remains accurate in ambient temperatures from -10 degrees to 50 degrees celsius (14 degrees to 122 degrees fahrenheit). With a superior probe design combined with electronic functions that assist accurate measurement, the “Stik" Thermometer surpasses the capabilities of other digital thermometers and is the perfect substitute for your mercury thermometers. 1In order to minimize sensor drift, the probe should always be protected from mechanical shock.

• Accuracy of +/- 0.05°C (+/- 0.09°F) over full range
• Intrinsically safe (ATEX and IECEx compliant)
• Two models to choose from (-50°C - 160°C or -80°C - 300°C)
• User-configurable temperature Trend/Stability indicator
• Display temperature in °C or °F
• Optional data logging to internal memory
• 300 h battery life
• Percent battery-life and low-battery indicator
• NVLAP-accredited, NIST-traceable calibration included

Temperature Range1551A: -50°C - 160°C (-58°F - 320°F)
1552A: -80°C - 300°C (-112°F - 572°F)
Accuracy (1 year)+/- 0.05°C (+/- 0.09°F)
Display Units°C, °F
Sensor Type1551A: 100 Ω thin-film RTD
1552A: 100 Ω wire-wound PRT
Probe Temperature Coefficient0.00385 Ω/Ω/°C nominal
Sensor Length1551A: ≤ 10 mm
1552A: ≤ 30 mm
Sensor Position (From Sheath Tip)3 mm (0.1 in)
Minimum Immersion Depth1551A: 7 cm (2.8 in)
1552A: 12 cm (4.8 in)
Probe Sheath MaterialStainless steel
Response Time4.8 mm diameter probe (3/16 in): 14 seconds
6.35 mm diameter probe (1/4 in): 21 seconds
Probe Hysteresis+/- 0.01°C
Temperature ResolutionSelectable: 0.1, 0.01, 0.001 (default 0.01)
Sample RateSelectable: 0.5 seconds, 1 seconds, 2 seconds (default 1 seconds)
Operating Temperature Range Readout-10°C - 50°C (14°F - 122°F)
Temperature ResolutionSelectable: 0.1, 0.01, 0.001 (default 0.01)
Sample RateSelectable: 0.5 seconds, 1 seconds, 2 seconds (default 1 seconds)
Operating Temperature Range Readout-10°C - 50°C (14°F - 122°F)
Storage Temperature-20°C - 60°C (-4°F - 140°F) 0 % to 95 % RH, non-condensing
Optional Data Logging[1]Up to 10,000 time-stamped readings stored to internal memory
Logging Intervals[1] 2 seconds, 5 seconds, 10 seconds, 30 seconds, or 60 seconds;
2 minutes, 5 minutes, 10 minutes, 30 minutes, or 60 minutes
DampingMoving average of the most recent 2 to 10 readings
(ON/OFF, 2, 5, 10)
CommunicationsRS-232 stereo jack (access calibration parameters only)
AC PowerNone
DC Power3 AAA Batteries, typical battery life of 300 hours without LCD backlight
EMC ComplianceEN61326:2006 Annex C; CISPR II Edition 5.0-2009; Class “B
Enclosure RatingIP50
Electronics Dimensions (H x W x D)114 mm x 57 mm x 25 mm (4.5 in x 2.25 in x 1.0 in)
Weight196 g (6.9 oz)
Calibration (Included)NVLAP-accredited, NIST-traceable
Characterization1551A: CVD
1552A: ITS-90
  • Thumbnail of document Manual - 1551A / 1552A Ex "Stik" Thermometer Readout
    Download

    Manual - 1551A / 1552A Ex "Stik" Thermometer Readout

    Download
  • Thumbnail of document Data Sheet - 1551A / 1552A Ex "Stik" Thermometer Readout
    Download

    Data Sheet - 1551A / 1552A Ex "Stik" Thermometer Readout

    Download

Accessories

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more