Skip to main content
Press Enter
Buy now! $585.90CAD
Georg Fischer GF Signet

2724-2726 pH/ORP Electrodes

DryLoc® connector w/ corrosion-resistant gold-plated contacts readily connects the sensor to the mating 2760 preamplifier

Buy now!
$585.90CAD
Have questions? We're here to help!
Have questions? We're here to help!

The 2724-2726 pH and ORP electrodes are general purpose sensors ideal for a wide range of applications.  These feature a patented reference design and uses the unique foul-proof patented DryLoc® connector.  The large area PE reference junction and pathway is constructed to increase the total reference eff ectiveness and ensures long service life.  The DryLoc® connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2751 pH/ORP Smart Sensor Electronics or the 2760 Preamplifi er.  The robust PPS threaded sensor body and choice of fl at pH, bulb pH, or fl at ORP sensing elements allows a broad range of chemical and mechanical compatibility for a wide variety of applications.  There are two optional pH sensing versions available, HF and LC. The HF version is for applications where traces of hydrofl uoric acid (2% or less) will attack standard pH glass.  The LC version can be used for low conductivity fl uids 20 - 100 µS/cm nominal and below 20 µS/cm when mounted under controlled conditions. The quick temperature response is available in either a Pt1000 or 3 KΩ temperature sensor and allows compatibility with all pH/ORP instruments.  The 27242726 electrodes incorporate ¾ inch NPT or ISO 7/1-R 3/4 threads for installing into GF standard pipe-tees.  They can also be mounted directly into standard fittings, DN15 to DN100 (½ to 4 inch).

• Patented reference design for exceptional performance
• Mounts in Signet standard fittings from DN15 to DN100 (½ to 4 in.)
• ¾” NPT or ISO 7/1-R 3/4 threaded sensors for use with reducing tees DN15 to DN100 (½ to 4 in.)
• Special design allows for installation at any angle, even inverted or horizontal
• Ryton® (PPS) body for broad range of chemical compatibility
• Patented DryLoc® connector with gold plated contacts
• Quick temperature response
• HF resistant glass available for trace HF of ≤2%
• Low conductivity sensor available for liquids down to 20 μS/cm

• The pH or ORP electrode mounting options shall include inline via ¾" MNPT process connection or submersible.
• The pH or ORP electrode shall have built-in temperature compensation, utilizing 3k ohm balco, or PT 1000, and ORP shall utilize a 10 k ohm ID resistor for self configuring transmitters
• The pH electrode shall have a measurement range of 0–14pH, and ORP electrode shell have a measurement range of +/- 2000 millivolts.
• The pH or ORP electrodes shall be capable of being mounted at any position around a horizontal or vertical pipe.
• The bulb-style pH electrode shall be available for general purpose measurements with optional low conductivity from 20 µS–100 µS, or optional HF service equal to or below 2% concentration.
• The pH or ORP electrodes shall have an operating temperature range of -10°C–85°C (14°F–185°F), with a pressure range of -10°C–65°C (14°F–149°F) @ 0–100 psi.
• The pH electrode wetted materials shall be Ryton (PPS-PolyPhenylene Sulfide) body, glass sensing surface, and UHMW PE reference junction, with FPM seals.
• The ORP electrode wetted materials shall be Ryton (PPS) body, platinum  sensing surface, and UHMW PE reference junction, with FPM seals.
• The pH or ORP electrodes shall utilize DryLoc connection pH/ORP pre-amps and blind transmitters.
• The pH electrodes shall be Georg Fischer Signet model 2724 flat glass or equal, or 2726 bulb or equal; ORP electrode shall be a 2725 or equal.

• Water and Wastewater Treatment
• Neutralization Systems
• Scrubber Control
• Effluent Monitoring
• Sanitization Systems
• Pool and Spa Control
• Aquatic Animal Life Support Systems
• Process Control
• Cooling Towers

  • Thumbnail of document Data Sheet - 2724-2726 pH/ORP Electrodes
    Download

    Data Sheet - 2724-2726 pH/ORP Electrodes

    Download
  • Thumbnail of document Manual - 2724-2726 pH/ORP Electrodes
    Download

    Manual - 2724-2726 pH/ORP Electrodes

    Download

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more