2764-2767 Differential pH/ORP Electrodes

Differential pH & ORP electrodes are built with the DryLoc® connector, a Ryton® body, and a PTFET reference junction

This product is no longer available. Contact us at 800-567-8686 for alternative solutions.

Have questions? We're here to help!
Have questions? We're here to help!

The Signet 2764-2767 Differential pH & ORP electrodes are built with the DryLoc® connector, a Ryton® body, and a PTFET reference junction to handle even the most extreme and harshest of chemical applications.

These differential electrodes use field-proven 3-electrode differential technique: the pH and reference electrodes are measured against a ground electrode, ensuring a steady and stable signal. A key feature is the reference electrode which is protected in a glass half-cell embedded in the reference chamber and is protected from compounds that may contain sulfides (S2-) and metals. To ensure long service life, the reference features a refillable electrolyte chamber and a replaceable equitransferant salt bridge. The patented porous PTFE reference junction resists fouling, clogging and chemical attack.

Other elements of the design are the solution ground, the pH/ORP electrodes, and the temperature element. The solution ground eliminates noisy measurements by draining electrical current away from the reference electrode. The pH/ORP electrodes are designed with a flat or bulb measurement surface, and a temperature device that is positioned at the tip of the measurement surface, making the temperature response of T95% less than one minute. Various temperature devices offered include 3KΩ, 300Ω, or PT1000 RTD. The electrodes are used with the Signet 2750 Sensor Electronics, which provide a blind 4 to 20 mA output or use the digital (S3L) output to connect to Signet's 8900 or 9900 instruments. The electrodes can also be used with the Model 2760 preamplifier to connect to the Signet 8750 instruments.

• Differential design for stable measurements in the most aggressive applications
• Long service life even in severe or difficult chemical applications
• Water-tight DryLoc® connector with foulproof gold contacts
• Porous PTFE reference junction
• Rebuildable reference electrode
• Solution ground
• Temperature sensor (pH)
• Quick temperature response
• Easy sensor replacement using DryLoc® electrode connector
• Compatible with all Signet instruments and other supplier's instruments
 

• The pH or ORP electrodes shall use three electrode differential technology.
• The pH or ORP electrode mounting options shall include inline via 1" MNPT process connection or submersible.
• The pH electrode shall have built-in temperature compensation, utilizing 3k ohm balco, or PT 1000, and ORP shall utilize a 10 k ohm ID resistor for self-configuring transmitters
• The pH electrode shall have a measurement range of 0–14pH, and ORP electrode shall have a measurement range of +/- 1500 millivolts.
• The pH or ORP electrodes shall have an operating temperature range of 0°C–95°C (32°F–203°F), with a maximum operating pressure range of 100 psi.
• The pH electrode wetted materials shall be Ryton (PPS - PolyPhenylene Sulfide) body, glass sensing surface, and PTFE reference junction, with FPM seals.
• The ORP electrode wetted materials shall be Ryton (PPS) body, platinum sensing surface, and PTFE reference junction, with FPM seals.
• The pH or ORP electrodes shall have a refillable reference chamber, and replaceable junction.
• The pH or ORP electrodes shall utilize DryLoc connection pH/ORP pre-amps and blind transmitters.
• The pH electrodes shall be Georg Fischer Signet model 2764 flat glass or equal, or 2766 bulb or equal; ORP electrode shall be a 2765 bulb or 2767 flat or equal

• Water and Wastewater Treatment
• Coagulation and Flocculation
• Plant Effluent
• Plating Baths
• Scrubbers
• Textile Dye Process
• Harsh Chemical Applications
• Heavy Metal Removal and Recovery
• Toxics Destruction
• Surface Finishing

  • Thumbnail of document Data Sheet - 2764-2767  Differential pH/ORP Electrodes
    Download

    Data Sheet - 2764-2767 Differential pH/ORP Electrodes

    Download
  • Thumbnail of document Manual - 2764-2767  Differential pH/ORP Electrodes
    Download

    Manual - 2764-2767 Differential pH/ORP Electrodes

    Download

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more