Skip to main content
Press Enter
Starting at $808.50CAD
Configure
Madgetech

Bridge101A Data Logger

Measures & records voltage, available in 3 different measurement ranges, reading rate of up to 4 Hz w/ memory capacity of 1,000,000 readings

Starting at
$808.50CAD
Have questions? We're here to help!
Have questions? We're here to help!
Configure
The Bridge101A is a compact, data logger that measures and records voltage, and is typically used in conjunction with strain gauges, load cells, and other low-level DC voltage sources. This device is designed to accurately calculate the output of the gauge to determine parameter levels such as stress, torque, strain, and pressure over a period of time.
 
Available in three different measurement ranges (±32 mV, ±160 mV or ±1200mV), the Bridge101A offers a reading rate of up to 4 Hz with a memory capacity of 2,095,104 readings. The device can be configured to start at a specified date and time up to 24 months in advance or by using the push button start/stop feature.
 
The Bridge101A is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.

• Multiple Start/Stop functions
• Ultra high speed download
• 1 million reading storage capacity
• Memory wrap
• Battery life indicator
• Optional password protection
• Programmable alarm
• Field upgradeable

Bridge Range±30 mv, ±150 mv, ±1000 mv
Bridge Resolution±30 mV: 1 μV
±150 mV: 5 μV
±1000 mV: 50 μV
Bridge Accuracy±30 mV: ±0.01 %FSR; ±3 MicroVolts
±150 mV: ±0.01 %FSR; 16 Microvolts
±1000 mV: ±0.01 %FSR; 120 Microvolts
Memory1,000,000 readings; software configurable memory wrap;
330,000 readings in multiple start/stop
Reading Rate4 Hz to 1 every 24 hours
Baud Rate115,200
Battery Life10 months typical at a 1 minute reading rate with a 350 Ω load
2 years typical at a 1 minute reading rate with a 1000 Ω load
MaterialABS Plastic
Dimensions1.4 in x 2.5 in x 0.6 in (36 mm x 64 mm x 16 mm)
Operating Environment-40 °C to +80 °C (-40 °F to +176 °F), 0 %RH to 90 %RH non-condensing
Required Interface PackageIFC200

• Strain gauge
• Load cell
• Pressure transducer
• Torque sensors
• Load bolts
• Position transducer

  • Thumbnail of document Data Sheet - Bridge101A Data Logger
    Download

    Data Sheet - Bridge101A Data Logger

    Download
  • Thumbnail of document Manual - Bridge101A Data Logger
    Download

    Manual - Bridge101A Data Logger

    Download

Accessories

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more