 With the CL540ZA you can check and calibrate all your thermocouple instruments. Connect via a miniature thermocouple connector on the top end of the source. Use your own thermocouple wire connectors or order one of the cable accessories for easy operation out of the box. Easy to operate even in the dark areas of the plant with the backlit display. Stop carrying around a millivolt source and thermocouple tables. The CL540ZA works with the thermocouples you use including Types J, K, T, E, R, S, B, N, G, C, D, L (J-DIN), U (T-DIN) and P (Platinel II). Easily set any value quickly to within 0.1° with the adjustable digital potentiometer “DIAL” plus store any three temperatures for instant recall with the selector switch. You can also calibrate from -13.000 to +80.000 mV. Connect directly to the thermocouple inputs of smart transmitters, PLCs, controllers and multichannel recorders and verify their outputs or displays.

 
• Source 14 Thermocouple Types
• Easy-to-Read Backlight Display
• Easily Change Thermocouple Types and Scale
• Calibrate Directly in Temperature (°C or °F)
Accuracy±(0.015% of Reading + 0.006 mV)
Cold Junction Compensation±0.25°C (±0.45°F)
Operating Temperature Range-25 to 60°C (-10 to 140°F)
Millivolt Range-13.000 to 80.000 mV
Relative Humidity Range10% ? RH ? 90% 0 to 35°C (32 to 95°F), non-condensing. 10% ? RH ? 70% 35 to 60°C (95 to 140°F), non-condensing
Dimensions126 L x 69 W x 45 mm D (4.96 x 2.73 x 1.79")
With Boot144 L x 78 W x 52 mm D (5.67 x 3.06 x 2.05")
Weight238 g (8.4 oz) (including batteries)
With Boot311.8 g (11 oz) (including batteries)
BatteriesFour "AA" Alkaline 1.5V (included)
Battery Life50 hours
Low BatteryLow battery indication with nominal 1 hour of operation left
Protection Against MisconnectionOver-voltage protection to 60 Vdc (rated for 30 seconds)
DisplayHigh contrast graphic liquid crystal display. LED backlighting for use in low lit areas
Source
Output Impedance< 0.3 ?
Source Current> 20 mA (drives 80 mV into 10 ?)
Noise?4 microvolts p-p for frequencies of 10 Hz or below
  • Thumbnail of document Manual - CL540ZA 14 Thermocouple Types and Millivolt Calibrator & Simulator
    Download

    Manual - CL540ZA 14 Thermocouple Types and Millivolt Calibrator & Simulator

    Download

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more