Skip to main content
Press Enter
Michell Instruments

Condumax II and Optipeak TDL 600

Assurance of the most widely accepted automatic hydrocarbon dew point analyzer together w/ the latest development of spectroscopic moisture measurement techniques

Have questions? We're here to help!
Have questions? We're here to help!

Combined Hydrocarbon Dew Point and Moisture Analyzer for Natural Gas Transmission Pipeline Quality.

Hydrocarbon dew point (HCDP) and moisture are key quality parameters to ensure the quality of pipeline transmission gas. With the combined Condumax II and OptiPEAK TDL600 analyzer system pipeline operators have the assurance of the most widely accepted automatic hydrocarbon dew point analyzer together with the latest development of spectroscopic moisture measurement techniques in a single, convenient analyzer system.

MOISTURE

• Measurement range: 1ppmV to 1000ppmV
• Measurement technology: Tuneable Diode Laser Spectroscopy
• Latest generation of TDLAS – moisture measurements are independent to changes in background gas composition
• Class-leading accuracy ±1ppmV even with widely varying gas compositions

HYDROCARBON DEW POINT

• HCDP measurement range: up to ∆ 55K measurement depression from main unit operating temperature
• HCDP measurement technology: direct photo-detection of hydrocarbon condensate
• Largest installation fleet across six continents


 GENERAL

• Low maintenance
• Easy to install with a small footprint

 

SPECIFICATIONS FOR CONDUMAX II
Hydrocarbon Dew-Point Measurement
Measuring TechniqueDark SpotTM fixed sample analysis.
Direct photo-detection of hydrocarbon condensate at hydrocarbon dew-point temperature
Sensor CoolingAutomatic via 3-stage Peltier effect electronic cooler under adaptive control
Maximum RangeUp to Δ -55K measurement depression from Main Unit operating temperature
Accuracy±0.5°C hydrocarbon dew point (single and multiple condensible component analysis)
Sample Flow0.03m³/hr (0.5 Nl/min) - alarm standard
Measurement Frequency6 cycles/hour (recommended)
12 cycles/hour (maximum)
Operating PressureMax. 100 barg (1450 psig)
Water Dew-Point Measurement (Optional)
Measuring Technique Michell Ceramic Moisture Sensor
Units - Moisture Content °C and °F water dew point; lb/MMscf; mg/m3, ppmV
Resolution 0.1°C, 0.1°F
Range Calibrated from -100 to +20°C dew point
Accuracy±1°C from -59 to +20°C dew point
±2°C from -100 to -60°C dew point
Sample Flow 0.06 to 0.3 m3/hr (1 to 5 Nl/min) alarm standard
Temperature Coefficient Algorithm compensation (-20 to +50°C)
Operating Pressure Max. 138 barg (2000 psig)
RangeHC dew point: 0 to 100 barg
W dew point: 0 to 200 barg
Accuracy ±0.25% FS
Hydrocarbon Dew-Point Analyzer
Resolution Hydrocarbon and water dew point: 0.1°C
Sample Gas Supply Natural gas up to 100 barg, pressure regulated in sampling system
Enclosure EExd cast enclosure with removable glass window viewing port. Internally heated for condensation
Sample Gas Connections1/8” NPT (ATEX / IECEx) or 1/4” NPT (CSA) female ports for both hydrocarbon and water dew-point
Operating Environment Indoors/Outdoors -20 to +50°C; Max 95% RH
Power Supply90 to 260 V AC, 50/60 Hz, 125 W Main Unit
300 W c/w Sampling System (indoor)
Weight22.5kg Main Unit
60kg (approx) c/w Sampling System (indoor)
Integrated Display/KeyboardTouch screen with vacuum fluorescent display
OutputsModbus RTU, RS485 @ 9600 baud rate
Two 4-20 mA linear (non-isolated) outputs, user-configurable for any combination of dew-point or pressure parameters
AlarmsProcess and analyzer status via software register and display annotation
Certification
Hazardous Area CertificationATEX: II 2G Ex d IIB + H2 Gb
(-40°C to +44°C) T6
(-40°C to +59°C) T5
IECEx: Ex d IIB + H2 Gb
(-40°C to +44°C) T6
(-40°C to +59°C) T5
cCSAus: Class I, Division 1, Groups B, C and D,
T6 (Tamb= -40°C to +44°C)
T5 (Tamb= -40°C to +59°C)
Pattern Approval GOST-R, GOST-K, GOST-T
SPECIFICATIONS FOR TDL600
Technical Specification
Measuring TechniqueTDLAS
Measurement Range1 ppmV to 1000ppmV
Accuracy±1% of reading > 100ppmV
±1ppmV < 100ppmV
Repeatability<1ppmV (long term stability <0.1ppmV/year)
Limit of Detection1ppmV
Available UnitsppmV, lb/MMSCF, mg/Nm3, dew point °C or °F (ISO18453 or IGT#8)
Response SpeedOptical response 0.2s
Display update 2-3s
Environmental Conditions Indoor version: –10°C to +45°C
Outdoor version:* –20°C to +45°C
Outdoor with cooling option:* –20°C to +55°C
Electrical Specifications
Supply Voltage110 V AC or 230 V AC 50/60Hz
Power RequirementsIndoor version: 80W
Outdoor version: 180W
Analog Signals Input: 2 x 4-20 mA user configurable
Output: 3 x 4-20 mA,3 alarms 250 V AC, 3A (volt-free contacts)
Digital CommunicationsRS485 ModBus RTU
Data LoggingLogs all process variables with a user selectable sample period in the range 10s to 1 day
Local Interface4.3” color LCD with touch pad operation
Electrical Connections3 x M20 entries for cable glands
Calibration
Factory Method3-point, traceable to NPL and NIST
Recommended CalibrationNone required, dependant on user or quality system requirements
Physical Specifications
Sample Flow Rate1 Nl/min cell sample, 1 to 5 Nl/min sample filter by-pass
Inlet PressureMaximum 100 barg (1450 psig)
Outlet PressureCell vent 0.7 to 1.4 bara, Filter by-pass maximum 3 barg
Enclosure Type/ PackagingAluminium alloy, explosion proof, polyester coated, IP66, NEMA4
Gas Connections1/4” NPT(F)
Weight40kg (88lbs) (without sampling system)
Sample System Enclosure304L or 316L stainless steel
Hazardous Area CertificationATEX: II 2 G Ex d ib op is IIC T5 Gb
IECEx: Ex d ib op is IIC T5 Gb
Tamb –20°C to +60°C
cQPSus: Class I, Division 1, Groups A, B, C, D, T5,
Tamb –20°C to +60°C, IP66
TC TR Ex: 1 Ex d ib op is IIC T5 Gb

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more