CurrentX Current Data Logger

Includes 4, 8, 12 and 16-channel low-level DC current data loggers, accepts signals from common voltage sources

Starting at
$1,071.00CAD
Have questions? We're here to help!
Have questions? We're here to help!
Configure

The CurrentX Series includes 4, 8, 12 and 16-channel low-level DC current data loggers and are available in three ranges: 30 mA, 160 mA, and 3 A.

The CurrentX Series accepts voltage signals from sensors, transducers and many other common voltage sources. Capable of measuring and recording up to 4,192,256 readings, users have the option to enable or disable channels to maximize memory capacity. There’s no interface necessary, the CurrentX Series uses standard USB-A to Micro USB cable.

Using the MadgeTech Software, starting, stopping and downloading from the CurrentX Series data loggers are simple and easy. Graphical, tabular and statistical data is provided for analysis and data can be viewed in multiple units, using the Engineering Units function. The data can also be automatically exported to Excel® for further calculations.

• 16-bit Readings Provide High Resolution
• User-defined Engineering Units
• Pushbutton or Programmable Start Time
• External Power or User Replaceable Battery
• Real Time Operation
• Up to 4 Hz Reading Rate
• Title Channels

Memory4-channel: 1,048,064 readings per channel
8-channel: 524,032 readings per channel
12-channel: 349,354 readings per channel
16-channel: 262,016 readings per channel
(all channels enabled)
Reading Rate4 Hz to 1 reading every 24 hours
Channels4, 8, 12, 16
LED Indicators1 per channel and 2 status LEDs
Battery Life18 months
MaterialBlack anodized aluminum
Dimensions4-channel: 2.70 in x 7.25 in x 1.22 in (65.6 mm x 184.2 mm x 31.0 mm)
8-channel: 2.70 in x 7.25 in x 1.22 in (65.6 mm x 184.2 mm x 31.0 mm)
12-channel: 2.70 in x 7.25 in x 1.68 in (65.6 mm x 184.2 mm x 42.7 mm)
16-channel: 2.70 in x 7.25 in x 2.14 in (65.6 mm x 184.2 mm x 54.4 mm)
Operating Environment-20 °C to +60 °C (-4 °F to +140 °F), 0 %RH to 95 %RH non-condensing
Current Range-2 mA to +30 mA, ±160 mA, ±3 A
Max Voltage: Inputs & Ground3 V
(Common mode voltage must be less than 3 volts. All inputs must be within 3 volts of all other inputs.)
Current Resolution30mA: 0.0005 mA
160mA: 0.005 mA
3A: 0.001 A
Current Calibrate Accuracy30mA: ±0.016 mA
160mA: ±0.16 mA
3A: ±0.009 A
Current Input Impedance30mA: 10 Ω
160mA: 1 Ω
3A: 0.1 Ω

• 4 mA to 20 mA Current Loops
• pH Recording
• Low Level Signal Monitoring
• Photovoltaic Studies
• Battery Studies
• Biological Sensor Monitoring
• Factory Process Control
• Research and Development
• Medical and Pharmaceutical
• Environmental Studies

  • Thumbnail of document Manual - CurrentX Current Data Logger
    Download

    Manual - CurrentX Current Data Logger

    Download
  • Thumbnail of document Data Sheet - CurrentX Current Data Logger
    Download

    Data Sheet - CurrentX Current Data Logger

    Download

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more