DMD4059-DC DIN Rail Conditioners Convert Bridge Inputs to mA or Voltage

Bridge/Strain Gage Signal Conditioner

Normally ships in
2-3 weeks
Have questions? We're here to help!
Have questions? We're here to help!
Configure

Supported Applications

The Omega DMD4059 Series is a field-rangeable, isolated signal conditioner designed for bridge and strain gage sensors. The series accepts inputs from one to four full Wheatstone bridges (100 Ω to 10,000 Ω) or pressure transducers, filtering and amplifying millivolt signals into linear DC voltage or current outputs. Documented applications include load cell weighing systems, strain gage pressure transducer monitoring, and tank level or flow measurement.

Operating Conditions & Performance

The DMD4059 operates within an ambient temperature range of -10°C to +60°C (14°F to 140°F). The module provides full 3-way isolation (input, output, and power) rated at 1200V for ground loop elimination. Accuracy specifications include better than ±0.1% of span linearity and stability better than ±0.02% of span per °C within the ambient temperature range.

Response time is typically 70 milliseconds (14.2 Hz). A DF option provides a typical response time of 10 milliseconds (100 Hz). The unit features an adjustable excitation power supply selectable from 0 to 10 VDC in 1 V increments, with a maximum output capability of 10 VDC at 120 mA. Load resistance is specified up to four 350 Ω bridges at 10 VDC.

Configuration Options

The series supports DIN rail mounting in an enclosure rated IP40 (IP 40). Dimensions are 0.89" W x 4.62" H x 4.81" D (22.5 mm W x 117 mm H x 122 mm D), with a weight of 159 g (5.6 oz). Electrical connections utilize four 4-terminal removable connectors supporting up to 14 AWG wire size.

Configuration options include:

• Power Supply Options: Standard models accept 85-265 VAC, 50/60 Hz or 60-300 VDC. The DMD4059-DC variant accepts 9-30 VDC or 10-32 VAC.
• Output Signals: Configurable DC voltage outputs include 0-1 to 0-10V, ±5V, and ±10V. Current output options range from 0-1 mA to 4-20 mA (Sink or Source).
• Input Ranges: Supports bridge inputs with sensitivities from 0.5 mV/V to 40 mV/V, covering input ranges of 0 to 5 mV through 0 to 400 mV.
• Calibration Options: The M01 option includes a switch with an internal calibration resistor; the M02 option provides a switch for external (load cell) calibration resistors.

The module features field-configurable input, output, excitation, and zero offset settings via rotary switches. A test button is included for diagnostic purposes.

Key Product Differences

The series consists of two primary model configurations distinguished by power supply requirements:

• DMD4059 (Standard): An isolated strain gage signal conditioner powered by 85-265 VAC, 50/60 Hz or 60-300 VDC.
• DMD4059-DC: A low voltage isolated strain gage signal conditioner designed for operation on 9-30 VDC or 10-32 VAC power sources.

Both models share the same physical dimensions, IP40 enclosure rating, and measurement capabilities. The series is RoHS compliant, lead-free, made in the USA, and carries a lifetime warranty.

• Standard DIN Rail Mounting
• Non-Interactive Zero and Span
• Fast Setup - Over 100 I/O Ranges
• Removable Connectors
Adjustments±5% Via Multi-Turn Potentiometer
CMRR100 db min
Electrical ConnectionScrew Terminal
Electrical Output0 to 25 mA
Enclosure RatingsIP40
Height117 mm
Isolation1200 Vrms minimum, 3-way isolation, power to input, power to output and input to output
Length122 mm
MountingDIN Rail 35 mm Standard
Operating Temperature, Max60 °C
Operating Temperature, Min-10 °C
Output RippleBetter than ±0.1% of span, <10 mV rms ripple and noise
Power Consumption2 to 5 W
Resistance AccuracyBetter than ±0.01% per 1 Ω change in leadwire resistance
Series IDDMD4059-Series-Sig-Cond
Stability±0.01% per °C, Thermal: Better than ±0.02% of span per °C
Supply Power TypeAC/DC
Temperature Stability±0.01% per/°C; Better than ±0.02% of span per °C
Weight159 g
Width22.5 mm
Wire Gauge14 AWG
  • Download

    Data Sheet - DMD4059-DC DIN Rail Conditioners Convert Bridge Inputs to mA or Voltage

    Download
  • Download

    Manual - DMD4059-DC DIN Rail Conditioners Convert Bridge Inputs to mA or Voltage

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more