OMEGA

DPF64 Analog Input Ratemeter/Totalizer, 6 Digits Display, NEMA 4X

Analog Input Ratemeter/Totalizer

Normally ships in
2-3 weeks
Have questions? We're here to help!
Have questions? We're here to help!

Supported Applications

The Omega DPF60 Series comprises microprocessor-based digital rate indicators and integrating totalizers designed for voltage and current inputs. These units measure rate and total in a single enclosure, supporting front-panel programming and scaling. The series includes the DPF64 (ratemeter), DPF65 (batch controller with prewarn and preset relays), and DPF66 (combination ratemeter and batch controller). An optional square root extraction input is available for use with differential pressure flowmeters.

Operating Conditions & Performance

The series accepts analog signal inputs including 0 to 20 mA, 4-20 mA, 0 to 5 V, and 0 to 10 V. Accuracy is specified as ±0.15% FS for rate and total in the primary data sheet; a secondary manual lists worst-case errors of 0.1% FS (4-20 mA), 0.2% FS (0-10 VDC), and 0.25% FS (0-5 VDC or 1-5 VDC). The display provides 6 digits for total flow with a floating decimal point, while the rate function displays up to 5 digits.

Operating ambient temperature ranges from 41°F (5°C) to 129°F (54°C), and storage temperatures are rated from -40°F (-40°C) to 199°F (93°C). The unit features a front panel protection rating of NEMA 4X (IP66). Non-volatile RAM retains scale settings, presets, output status, and total flow for up to 1 year without power. A regulated power output is provided at ±5% 24 VDC @ 50 mA.

Key Performance Specifications

• Accuracy: ±0.15% FS (rate and total); alternative values include 0.1% to 0.25% FS depending on input range per secondary documentation.
• Display Resolution: 6-digits for total, 5-digits for rate; LED size is 15 x 8 mm (0.6 x 0.32").
• Hysteresis: Rate alarm acts as a window alarm with hysteresis around the setpoint.
• Power Supply: Standard 94 to 126 VAC, 50/60 Hz (or 12 to 24 VDC); optional 187 to 253 VAC or 12 to 24 VDC.

Configuration Options

The DPF60 Series is configurable for specific control and communication needs through model selection and suffix options. The series supports front-panel reset, adjustable zero and span, and relay outputs that can latch or auto-recycle after 0.1 to 99.9 seconds.

Model Functions

• DPF64: Ratemeter with two separate 5 A SPDT alarms.
• DPF65: Batch controller featuring prewarn and preset capabilities using 5 A SPDT relays.
• DPF66: Combination ratemeter and batch controller; allows toggling between rate of flow and total flow from the front panel, with two separate 5 A SPDT relays for rate alarm or batching.

Available Options & Suffixes

• -A: Analog output, 4 to 20 mA proportional to rate (for controlling strip recorders or peripherals).
• -SQRT: Square root extraction for differential pressure flowmeters.
• -RS232: RS-232 serial communications.
• -RS422: RS-422 serial communications.

The unit is housed in a 1/8 DIN enclosure with dimensions of 92 mm W x 45 mm H (3.622" x 1.772") and a depth of 112 mm (4.4"). A panel punch, model DPP-5, is available for installation.

Key Product Differences

The primary distinction within the series lies in the functional mode: DPF64 models display rate only; DPF65 models function as batch controllers displaying total flow with prewarn/preset logic; and DPF66 models combine both functions, allowing front-panel toggling between rate and total. All three base models include two 5 A SPDT relays configured according to their specific mode (alarms for DPF64/DPF66, batch control for DPF65).

Power supply variations are indicated by the "-220VAC" suffix in part numbers, corresponding to the optional 187 to 253 VAC input range. The standard power configuration supports 94 to 126 VAC or 12 to 24 VDC. Additional functional capabilities such as analog output (-A), square root extraction (-SQRT), and serial communication protocols (RS-232, RS-422) are added via suffix options.

• Front Panel Programming and Scaling
• Rate and Total in 1 Unit
• Remote or Front Panel Reset
• Relays Latch or Auto-Recycle
Accuracy± 0.15 %
Accuracy Detail±0.15% FS for rate and total
ApprovalsCE, RoHS Compliance
Cutout Dimensions3.62 x 1.73 in
Display ColorRed
Display Note15 x 8 mm (0.6 x 0.32") LED—6-digits total, 5-digits rate
Display TypeLED
Enclosure MaterialPlastic
Enclosure RatingsIP66, NEMA Type 4X
Form factor1/8 DIN
Front Panel Dimensions4.437 x 2.625 in
Input TypeCurrent, Voltage
MemoryNon-Volatile Memory, 1 Year without Power
Mounting OrientationPanel Mount
Number of Digits6
Number of Inputs1
Operating Temperature, Max54 °C
Operating Temperature, Min5 °C
Panel Depth4.4 in
Sampling Rate5 Hz (5 updates/second)
Series IDDPF60
Storage Temperature, Max93 °C
Storage Temperature, Min-40 °C
Supply Power TypeAC/DC
Switch Rating5A @ 250 Vac
Switch TypeSPDT NO/NC, Selectable
  • Download

    Data Sheet - DPF64 Analog Input Ratemeter/Totalizer, 6 Digits Display, NEMA 4X

    Download
  • Download

    Manual - DPF64 Analog Input Ratemeter/Totalizer, 6 Digits Display, NEMA 4X

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more