Skip to main content
Press Enter
OMEGA

DRSL-DC3 DIN Rail Signal Conditioner Series w/Process Input

Isolated DIN Rail Signal Conditioner

Have questions? We're here to help!
Have questions? We're here to help!

 The DRSL-DC3 isolated DIN rail signal conditioner provides a competitive choice in terms of both price and technology for galvanic isolation of process voltage or current signals to SCADA systems or PLC equipment. The DRSL-DC3 can be used for signal conversion of standard process voltage or current signals. The unit offers isolation between input, output and supply, provides surge suppression and protects control systems from transients and noise.

 
The DRSL-DC3 also eliminates ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Factory calibrated measurement ranges are easily configured via DIP switches. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).
• Isolation and Conversion of Process Voltage or Current Signals
• Slimline Housing—Only 6 mm (0.24') Wide
• Multiple Signal Ranges (DIP-Switch Selectable)
• High Accuracy, <0.2% of Span
Screw Terminal Torque0.5 Nm
Wire Size0.13 x 2.5 mm2/AWG 26 to 12 stranded wire
DIN Rail TypeDIN EN 60715 - 35 mm
Weight70 g (0.15 lb) approx
Dimensions113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5”)
Mechanical
Installation AreaPollution degree 2 and measurement/overvoltage category II
Protection DegreeIP20
Relative Humidity0 to 95% RH non-condensing
Calibration Temperature20 to 28°C (68 to 82°F)
Storage Temperature-40 to 85°C (-40 to 185°F)
Operating Temperature-25 to 70°C (-13 to 158°F)
Environmental
NAMUR NE 21, A Criterion, Burst<±1% of span
Extended EMC Immunity
EMC Immunity Influence<±0.5% of span
Temperature Coefficient<±0.015% of span/°C
Accuracy<±0.2% of span
SpanCorresponds to the presently selected DIP switch output range
Response Time (0 to 90%, 100 to 10%)<7 ms
Signal/Noise Ratio>60 dB
MTBF>249 years, according to IEC 61709 (SN29500)
Isolation Voltage (Working)300 Vac
Isolation Voltage (Test)2.5 kVac
IsolationInput/Output/Supply
Internal Consumption0.4 W typical/ 0.65 W max
Power Consumption0.8 W ma
Supply Voltage (via Power Rail or Connectors)16.8 to 31.2 Vdc
General
Load>10 kΩ min
Programmable Signal Ranges0 to 10, 2 to 10, 0 to 5 and 1 to 5V
Signal Range0 to 10V
Voltage Output
Current Limit≤28 mA
Load Stability≤0.01% of span/ 100 Ω
Load23 mA/600 Ω max
Programmable Signal Ranges0 to 20 mA and 4 to 20 mA
Current Output
Output
Input Resistance≥500 kΩ
Programmable Measurement Ranges0 to 5V, 1 to 5V, 0 to 10V, 2 to 10V
Functional Range0 to 11.5V/ 0 to 5.75V
Measurement Range0 to 10.25V
Voltage Input
Input Voltage Drop< 1.5V
Programmable Measurement Ranges0 to 20 mA and 4 to 20 mA
Functional Range0 to 23 mA
Measurement Range0 to 20.5 mA
Current Input
Input
Signal Range0 to 20.5 mA (span)
  • Thumbnail of document Data Sheet - DRSL-DC3 DIN Rail Signal Conditioner Series w/Process Input
    Download

    Data Sheet - DRSL-DC3 DIN Rail Signal Conditioner Series w/Process Input