Skip to main content
Press Enter
OMEGA

DRST-BG DIN Rail Signal Conditioner for Load Cells

Signal Transmitter for Load Cell & Strain Gage Application

Have questions? We're here to help!
Have questions? We're here to help!

 Brand New DRST-BG MV Signal Transmitter converts bipolar mV signals from transducers supplied directly by the device to standard current/voltage signals.

 
Application
DRST-BG is suitable for load cell application as well as other applications such as tank filling and draining, weighing with a taring function, measurement of cable tensile force, level control, signal conversion/amplification.
Advanced Features
A multifunction user interface consisting of three push buttons and a 3-digit LED display for programming.
Technical Characteristics
    • Front error LED.
    • The analog input can be programmed for voltage in the range -40 to 100 m Vdc.
    • The digital signal can be selected as either NPN or PNP. Taring can either be by way of the digital input or from the front interface.
    • The analog output can be programmed to current in the range 0 to 20 mA or voltage in the range     • Short circuit protected transducer supply which can be programmed to 5 to 13 Vdc from the front.
    • Sense input (with transducer supply used) for compensation for cable resistance to the transducer.
    • Mounting for a standard 11-pole socket which can be adapted for DIN rail or plate.
 
• Load cell & Strain Gage Amplifier
• MV to Current/Voltage Conversion
• Front-Programmable/LED Display
• Relative Calibration of Input Span
EACTR-CU 020/2011
EMC2014/30/EU
Observed Authority Requirements
Of Span= of the presently selected range
ShuntSee manual for details
Voltage Output Through Internal
Current Limit< 23 mA
Load Stability= 0.01% of span/100 Ω
Load ( @ Current Output= 600 Ω
Min, Signal Range5 mA
Signal Range0 to 20 mA
Current Output
Output Specifications
Pulse Length> 30 ms
Trig Level High, NPN/PNP> 10.5 Vdc
Trig Level Low, NPN/PNP< 6 Vdc
PNP, digital InputPull down 0 Vdc/6.9 mA
NPN, Digital InputPull up 24 Vdc / 6.9 mA
Overrange0 to 999% of selected measurement range
Input Resistance> 10 MO
Min. Measurement Range (Span)10 mV
Measurement Range-40 to 100 mV
Voltage Input
Max. Offset70% of selec. max. value
Common Input Specifications
Input Specifications
EMC Immunity Influence< ±0.5% of span
Load (Max.)230 mA
Supply5 to 13 Vdc
Auxiliary VoltageTransducer
Linearity Error< 0.1% of span
Temperature Coefficient< ±0.01% of span/°C
Effect of Supply Voltage Change< ±0.002% of span/%V
Signal Dynamics, Output16 bit
Signal Dynamics, Input17 bit
Updating Time20 ms
Signal/Noise RatioMin. 60 dB
Response Time (Programmable)0.06 to 999 s
Internal Power Dissipation2.2 W
Max Required Power7.2 W
Supply Voltage19.2 to 28.8 Vdc
Common Specifications
Weight Approx130 g
Dimensions (HxWxD)80.5 x 35.5 x 84.5 mm (D is without pins)
Mechanical Specifications
Protection DegreeIP50
Relative Humidity< 95% RH (non-cond.)
Calibration Temperature20 to 28°C
Operating Temperature-20 to 60°C
Environmental Conditions
  • Thumbnail of document Manual - DRST-BG DIN Rail Signal Conditioner for Load Cells
    Download

    Manual - DRST-BG DIN Rail Signal Conditioner for Load Cells

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more