Skip to main content
Press Enter
OMEGA

DRST-UR DIN Rail Universal Programmable Signal Conditioner w/Relay Output

Universal Signal Transmitter with 2 Relay Output

Normally ships in
2-3 weeks
Have questions? We're here to help!
Have questions? We're here to help!

Supported Applications

The Omega DRST-UR is a DIN rail universal programmable signal conditioner and transmitter designed for industrial process automation. It accepts inputs from RTDs, thermocouples (TC), linear resistance sensors, potentiometers, current loops, and voltage signals to condition them into standardized outputs or relay actions.

Engineers deploy the DRST-UR in applications requiring:

• Signal conversion for temperature measurement using Pt10...Pt1000 (IEC 60751), Ni50...Ni1000 (DIN 43760), Cu10...Cu100, and thermocouple types B, E, J, K, L, N, R, S, T, U, W3, W5, and LR.
• Process monitoring with programmable setpoint or window relay outputs for alarm indication.
• Safety-critical installations designed according to strict safety requirements suitable for SIL 2 applications (IEC 61508).
• Hazardous location environments certified under FM Ex / I.S. Class I, Div. 2, Group A, B, C, D; Class I, Div. 2, Group IIC; and Zone 2.
• Marine applications approved by Det Norske Veritas (Ships & Offshore Standard for Certification No. 2.4).

Operating Conditions & Performance

The DRST-UR operates within an ambient temperature range of -20°C to +60°C, with a calibration reference at 20...28°C and relative humidity < 95% RH (non-condensing). The device features IP20 protection and is designed for vibration resistance per IEC 60068-2-6 : 2007.

Performance specifications include:

• Absolute Accuracy: ≤ ±0.1% of span (general value, all input types) with a temperature coefficient ≤ ±0.01% of span/°C.
• Basic Accuracy by Input Type: mA ≤ ±4 µA; Volt ≤ ±20 µV; Pt100 ≤ ±0.2°C; Linear resistance and Potentiometer ≤ ±0.1 Ω; TC E/J/K/L/N/T/U ≤ ±1°C; TC R/S/W3/W5/LR ≤ ±2°C; TC B (85...200°C) ≤ ±4°C; TC B (200...1820°C) ≤ ±2°C.
• Response Time: Temperature input ≤ 1 s (0...90%, 100...10%); mA / V input ≤ 400 ms.
• EMC Immunity Influence: < ±0.5% of span; extended EMC immunity NAMUR NE 21, A criterion, burst < ±1% of span.

The unit provides 4-port galvanic isolation with a test voltage of 2.3 kVAC and operational isolation of 250 VAC.

Configuration Options

The DRST-UR series supports extensive configuration options for inputs, outputs, and communication interfaces to accommodate diverse process requirements without requiring multiple hardware platforms.

Input Configurations

• RTD: Supports Pt10...Pt1000 (-200°C to +850°C), Ni50...Ni1000 (-60°C to +250°C), and Cu10...Cu100 (-200°C to +260°C). Includes sensor error detection, short circuit detection (< 15 Ω), and support for 3- or 4-wire connections.
• Thermocouple: Covers types B (0°C to +1820°C), E (-100°C to +1000°C), J (-100°C to +1200°C), K (-180°C to +1372°C), L, N, R, S, T, U, W3 (0°C to +2300°C), W5 (0°C to +2300°C), and LR. Features internal or external cold junction compensation (CJC) via connector 5910.
• Electrical: Linear resistance (0 Ω to 10,000 Ω), Potentiometer (10 Ω to 100 kΩ), Current input (programmable 0...20 mA or 4...20 mA), and Voltage input (programmable ranges including 0...1 VDC, 0...5 VDC, 0...10 VDC).

Output & Relay Functions

• Analog Output: Programmable current output (0...20 mA span; ranges include 4...20 / 20...0 / 20...4 mA) with a max load of 800 Ω at 16 VDC. Voltage output available in the 0...10 VDC range with programmable spans.
• Relay Outputs: Two relays rated for max. 250 VRMS, 2 A / AC or 1 A / DC (max. 500 VA). Configurable functions include Setpoint, Window, Sensor error, Latch, Power, and Off.
• Error Handling: Supports NAMUR NE 43 upscale/downscale signaling (23 mA / 3.5 mA) for sensor faults.

Housing & Mounting

The device mounts on a DIN rail per SYSTEM 4000, DIN 46277 standards with overall dimensions of 109 x 23.5 x 104 mm (HxBxD). Dimensions increase to 109 x 23.5 x 116/131 mm when equipped with the DRSL-DISPLAY or DRST-CM accessories.

Key Product Differences

The core model is identified as DRST-UR. Functional variations are achieved through configuration rather than distinct hardware SKUs, supported by optional accessories:

• DRSL-DISPLAY: A removable display and programming front that provides an LCD with 4 lines. It enables process calibration, signal simulation, relay simulation, password protection, error diagnostics, and help text in multiple languages. The unit can copy configuration from one DRST-UR to subsequent transmitters.
• DRST-CM: A communication enabler for data exchange capabilities.
• CJC Connector 5910: An external sensor connector (ordered separately) used for cold junction compensation in thermocouple applications, offering improved accuracy over internal CJC sensors when ambient temperatures deviate from the calibration range.

The series supports a universal power supply of 21.6...253 VAC (50...60 Hz) or 19.2...300 VDC with max consumption ≤ 2.5 W and an internal fuse rated at 400 mA SB / 250 VAC

• Input for RTD, TC, O, potentiometer, mA and V
• 2-wire supply 16 V
•  UL and cUL Approval
• Output for current, voltage and 2 relays
Accuracy± 0.1 %
ApprovalsUL: UL 508/C22.2 no. 14; DNV-GL Marine Stand. f. Certific. No. 2.4; EU RO Mutual Recognition Type; Approval: MRA000000Z SIL Hardware assessed for use in SIL applications; Authority Requirements:EMC: 2014/30/EU, LVD: 2014/35/EU, EAC: TR-CU 020/2011
Calibration Temperature, Max28 °C
Calibration Temperature, Min20 °C
Cold Junction Compensation20 to 28°C = ±1°C, -20 to 20°C/28 to 70°C = 2°C
Electrical Output0 to 20 mA, 0 to 10 Vdc
EMC Immunity NoteStandard EMC Imunity: <±0.5% of span; Extended EMC Immunity: NAMUR, NE21, A Criterion, Burst: <±1% of span; Wire Size: 1 x 2.5 mm²
Enclosure RatingsIP20
Fuse Rating250 Vac/400 mA
Height109 mm
Input Control Signal0 to 12 Vdc
Input Control Signal NoteMeasurement Range: 0 to 12 Vdc; Programmable Measurement Ranges: 0/0.2 to 1, 0/1 to 5, 0/2 to 10 Vdc
Input Current0 to 20 mA
Input_Current NoteProgrammable Measurement Ranges: 0 to 20 and 4 to 20 mA; Input Resistance: Nom. 20 Ω + PTC 50 Ω Sensor Error Detection: Loop; Break 4 to 20 mA: Yes
Input ResistanceVoltage : Nom. 10 MΩ,Current: Nom. 20 Ω + PTC 50 Ω
IsolationTest/Working: 2.3 kVac/250Vac
Length104 mm
Operating Temperature, Max60 °C
Operating Temperature, Min-20 °C
Output DetailSignal Range: 0 to 20 mA; Programmable Signal Ranges: 0 to 20/4 to 20/20 to 0/20 to 4 mA; NAMUR NE43 Upscale/Downscale: 23 mA/3.5 mA; Output Limitation, on 4 to 20 and 20 to 4 mA signals: 3.8 to 20.5 mA; Output Limitation, on 0 to 20 and 20 to 0 mA signals: 0 to 20.5 mA; Signal Range: 0 to 10 Vdc; Programmable Signal Ranges: 0/0.2 to 1; 0/1 to 5 ; 0/2 to 10; 1 to 0.2/0; 5 to 1/0; 10 to 2/0 V
Output SignalCurrent, Voltage, 2 Relays
Potentiometer Input Range10 to 100 kΩ
Power Consumption2.5 W
Relative Humidity< 95% RH Non-Condensing
Relay Output2 A @ 250 Vac
Relay Output NoteRelay Functions: Setpoint, Window, Sensor error, Latch, Power and Off
Response Time1 sec
Response Time NoteThermocouple: 1 sec, Current/Voltage: 400msec
RTD Input NoteEffect of Sensor Cable Resistance: < 0.002 Ω/Ω (3/4-wire); Cable Resistance, Per Wire: 50 Ω; Sensor Current: 0.2 mA; Short Circuit Protection: < 15 Ω; Sensor Error Current: 2 µA / 0 µA
RTD Type10/20/50/100/200/250/300/400/500/1000 Ω Pt Sensor, 50/100/120/1000 Ω Ni Sensor, 10/20/50/100 Ω Cu Sensor
Screw Terminal Torque0.5 Nm
Sensor/Transmitter Power25 to 16 Vdc/0 to 20 mA
Series IDDRST-UR-Univ-Sig-Cond
Signal/Noise Ratio> 60 dB
Storage Temperature, Max85 °C
Storage Temperature, Min-20 °C
Supply Power Note21.6 to 253 Vac, 50 to 60 Hz or 19.2 to 300 Vdc
Supply Power TypeAC/DC
Supply Voltage21.6 to 253 Vac, 19.2 to 300 Vdc
Temperature Coefficient≤±0.01% of span/°C
Temperature Measurement RangeJ: -100 to 1200°C, K: -180 to 1370 °C, T: -200 to 400 °C, E: -100 to 1000 °C, R: -50 to 1760 °C, S: -50 to 1760 °C, N: -180 to 1300 °C, B: 0 to 1820 °C, W3: 0 to 2300 °C, W5: 0 to 2300 °C, L: -200 to 900 °C, LR: -200 to 800 °C, RTD: -200 to 850 °C
Thermocouple TypeJ, K, T, E, N, R, S, U, B, G, C, D, L, LR
Vibration±0.7 g
Vibration NoteIEC 60068-2-6; 2 to 13.2 Hz: ±1 mm; 13.2 to 100 Hz: ±0.7 g
Weight170 g
Width23.5 mm
Wire TypeStranded
  • Download

    Manual - DRST-UR DIN Rail Universal Programmable Signal Conditioner w/Relay Output

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more