The EE046 warns early and reliably of a condensation risk. It thus helps to prevent dripping or mould at critical cold spots. The condensation monitor can be mounted on flat surfaces and on pipes.
 
Condensation on a surface occurs when the relative humidity (RH) of the air close to the surface reaches 100 %. The EE046 condensation monitor measures accurately the relative humidity of the air at the surface temperature. An early warning is given via the relay output when this reaches a value of 90 % RH, just before condensation occurs. The relay also indicates a power supply failure or a broken cable. Additionally, an LED indicates the operating status of the EE046 (normal operation / alarm / power supply failure).
 
The EE046 condensation monitor is available in two versions. The wall/pipe mount model is appropriate for installation on flat surfaces and on pipes with a diameter of up to 50 mm (2"). It is mounted on cooling ceilings, on cooling or cold water piping, cooled surfaces and chilled beams.
 
The snap-on model can be mounted on plastic and aluminium composite pipes with 16 mm (0.63") diameter. Typical applications for this model are cooling and heating by concrete core activation.
 
Because of the very good thermal coupling with the surface, the EE046 responds very quickly to humidity or surface temperature changes.
 
The high-quality humidity sensing element is protected against dust and dirt by the E+E proprietary coating. This ensures long-term stable and reliable measurements in harsh and polluted environments.
• Fast response time
• Dust protection
• Compact design and easy mounting
• LED status indication
 
Measuring Range10% - 100% RH
Switching Point90 ± 3% RH
Response Time at Change of the Surface Temperaturet90
Response Time at Change of the Relative Humidityt90
Max. Switch Load24 V AC/DC, 1 A
Supply24 V AC/DC
• Concrete core activation
• Chilled beams
• Switching cabinets
• Climate control
  • Thumbnail of document Manual - EE046 Condensation/Dew Point Monitor
    Download

    Manual - EE046 Condensation/Dew Point Monitor

    Download
  • Thumbnail of document Data Sheet - EE046 Condensation/Dew Point Monitor
    Download

    Data Sheet - EE046 Condensation/Dew Point Monitor

    Download

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more