Skip to main content
Press Enter
Starting at $3,670.00CAD
Configure
Rotronic

HC2-LDP-EX Low Dew Point Probe

Low dewpoint probe equipped with AirChip4000 technology, calculates a measurement from the average of 8,000 single points within a 2 second interval

Starting at
$3,670.00CAD
Have questions? We're here to help!
Have questions? We're here to help!
Configure
The ATEX Rotronic humidity and temperature probes can only be used with our HF5-EX ATEX transmitter in applications with explosive atmospheres. The probes measure temperature from -40…85°C and humidity from 0…100 % rH with an outstanding accuracy of ±0.8 % rH / ± 0.1 K. The probes are cast into a stainless-steel tube and are certified for operation in explosive atmosphere (Zone 0).
• Safe operation in areas with explosion risk
• Intrinsically safe probes
• Interchangeable probes for fast exchanges
Probe typeDigital dew point & temperature probe
Measuring range-70…85 °C Td / -40...85 °C
Dew point accuracy @ 23 °C±2 K Td (-50…20 °C Td); ±3.5 K Td (-60…-50 °C Td)
Temperature accuracy @ 23 °C±0.2 K
Dew point sensorHYGROMER® LDP-1
Long-term stability dew point sensor<1 °C Td/year
Response time dew point sensor Ƭ63: @ -50 °C TdTypically <10 min, with filter
Response time temperature sensor Ƭ63: @ -50 °C TdTypically <15 min, with filter
Pressure resistance16 bar, 100 bar (with LDP-MCS measurement chamber)
Power supply / Power consumption3.3...5 VDC / <1.5 mA
Temperature sensorPt1000, Class B 1/3
Filter cartridgeSintered stainless steel, 50 μm
Measurement interval2 seconds
Communication interfacesUART
HousingStainless steel 1.4301
IP protection ratingIP65
FDA/GAMP compatibilityYes
CE/EMC conform2004/108/EC
Identification EX North AmericaClass I, Div 1/2, Groups ABCD T5…T4; Class II, Div 1/2, Groups EFG T80°C…T110°C; Ex e mb [ia Ga] IIC T5...T4 Ga/Gb; Ex tb [ia Da] IIIC T80°C…T110°C Da/Db; Class I, Zone 0/1, AEx e mb [ia Ga] IIC T5…T4 Ga/Gb; Class II, Zone 20/21, AEx tb [ia Da] IIIC T80°C…T110°C Da/Db
MaintenanceAnnual calibration (recommended)
Storage and transport conditions-40…85 °C, non-condensing
Dimensions145 x 140 mm (probe head); Hexagonal nut: 3 x 140 mm
Weight260 g
  • Thumbnail of document Guide - HC2-LDP-EX Low Dew Point Probe
    Download

    Guide - HC2-LDP-EX Low Dew Point Probe

    Download
  • Thumbnail of document Data Sheet - HC2-LDP-EX Low Dew Point Probe
    Download

    Data Sheet - HC2-LDP-EX Low Dew Point Probe

    Download
  • Thumbnail of document Manual - HC2-LDP-EX Low Dew Point Probe
    Download

    Manual - HC2-LDP-EX Low Dew Point Probe

    Download

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more