Skip to main content
Press Enter
OMEGA

HH11C 1&2 Channel High Accuracy 0.1% Type K Thermocouple

0.1% Accuracy Handheld Thermometers | Single and Dual Channel Models

Normally ships in
2-3 weeks
Have questions? We're here to help!
Have questions? We're here to help!
Configure

 Supported Applications

The Omega HH11C and HH12C series comprises high-accuracy, portable digital thermometers designed for Type K (Chromic-Alum) thermocouple inputs. These handheld instruments follow National Bureau of Standards and IEC 584 temperature/voltage tables to measure process temperatures in industrial settings where a compact, battery-operated solution is required.

Key functional capabilities include:

• Data Capture Functions: MIN/MAX/AVG (average), REL (relative/delta), and HOLD functions for recording temperature extremes and differentials.
• User Adjustments: Front-panel offset adjustment allows users to calibrate readings against a reference standard or compensate for sensor placement errors.
• Dual-Channel Operation: The HH12C model provides simultaneous measurement on two independent Type K inputs, enabling differential temperature monitoring between two points.

Operating Conditions & Performance

The series is engineered for high-resolution readings with a 4½ digit liquid crystal display (LCD) capable of displaying values up to 19999. Measurement rates are specified at 2.5 times per second, providing rapid updates on changing thermal conditions.

• Measurement Range:-200°C to 1372°C (-328°F to 2502°F).
• Resolution (Auto-Range): 0.1 or 1° units depending on the selected range.
• Accuracy: ±(0.1% rdg + 0.5°C) for -50 to 1372°C (-58 to 2502°F); ±(0.1% rdg + 2°C) for -50 to -200°C (-58 to -328°F). Accuracy specifications apply at operating temperatures of 18°C to 28°C (64°F to 82°F).
• Temperature Coefficient: 0.1 times the applicable accuracy specification per °C from 0°C to 18°C and 28°C to 50°C.

Ambient operating conditions are limited to 0 to 50°C (32 to 122°F) at less than 80% relative humidity. Storage temperature ranges from -20 to 60°C (-4 to 140°F), with the battery removed, in environments of 0 to 80% RH.

Configuration Options

The series offers two primary configurations distinguished by channel count and physical weight. Both models utilize standard SMPW type connectors (flat blades spaced 7.9mm center-to-center) for thermocouple input; they are not compatible with NMP connectors.

• HH11C: Single-input high-accuracy digital thermometer. Weight is approximately 235 g (8.3 oz) including batteries.
• HH12C: Dual-input high-accuracy digital thermometer. Weight is approximately 240 g (8.5 oz) including batteries.

Power is supplied by a standard 9V battery (NEDA 1604, IEC 6F22), which is included with the unit. Typical battery life is cited as 100 hours when using a carbon zinc battery. A low-battery indication symbol appears on the LCD when voltage drops below operating levels.

Physical protection includes an integrated rubber boot (protective holster). The supplied thermocouple wire for the HH11C model consists of 4 feet of Type K bead wire with PTFE tape insulation, rated to a maximum temperature of 260°C (500°F).

Key Product Differences

The primary distinction between models in this series is the number of measurement channels:

• HH11C: Configured for a single Type K thermocouple input.
• HH12C: Configured for dual independent Type K thermocouple inputs, allowing simultaneous monitoring and differential calculations between two sensors.

Both models share identical measurement ranges, accuracy specifications, display resolution, environmental ratings, and connector types. The HH12C adds approximately 5 g (0.2 oz) to the total weight compared to the single-channel variant due to additional circuitry for dual input processing.

• Highly Accurate Thermometer with 0.1% Basic Accuracy
• Thermocouple Offset Adjust
• HH12C: Dual Input T1, T2, T1-T2
• Rugged Protective Holster, Included
Auto range0.1°C
Display Type4.5 Digit LCD
Electrical ConnectionMiniature Male Thermocouple Connector
Height185 mm
Measuring Temperature Range, Max1372 °C
Measuring Temperature Range, Min-200 °C
Operating Temperature, Max50 °C
Operating Temperature, Min0 °C
Series IDHH11C-HH12C
Storage Temperature, Max60 °C
Storage Temperature, Min-20 °C
Storage Temperature Note-20 to 60°C (-4 to140°F), 0 to 80% RH with battery removed from meter
Supply Voltage9 Vdc
Temperature Accuracy± 0.1% rdg + 0.5 °C
Temperature Accuracy Note± (0.1% rdg + 0.5°C) on -50 to 1372°C (-58 to 2502°F); ± (0.1% rdg + 2°C) on -50 to -200°C (-58 to -328°F) Type K (Chromic-Alum)
Temperature Resolution0.1 °C
Temperature Sensor TypeThermocouple
Thermocouple TypeK
Width65 mm
  • Download

    Manual - HH11C 1&2 Channel High Accuracy 0.1% Type K Thermocouple

    Download
  • Download

    Data Sheet - HH11C 1&2 Channel High Accuracy 0.1% Type K Thermocouple

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more