4-Channel Type-K Thermometer with Backlit Display

Normally ships in
3-4 weeks
Have questions? We're here to help!
Have questions? We're here to help!

Supported Applications

The Omega HH501DK Series is a portable, compact-sized digital thermometer designed to use external K-type thermocouples as temperature sensors. The instrument provides temperature indication following Reference Temperature/Voltage Tables (N.I.S.T. Monograph 175 Revised to ITS-90) for K-type thermocouples.

Applications are limited by specific safety warnings: the device is not designed for use in, and should not be used for, patient-connected applications. Additionally, temperature measurements must not be made inside microwave ovens to avoid damage or burns.

Operating Conditions & Performance

The HH501DK Series operates within an ambient range of 0°C to 50°C (32°F to 122°F) at less than 80% R.H. Storage is supported from -20°C to 60°C (-4°F to 140°F) at less than 70% R.H.

Measurement capabilities cover a range of -50°C to 1300°C (-58°F to 2000°F). Accuracy specifications, valid for operating temperatures between 18°C and 28°C (64°F to 82°F) over one year and excluding thermocouple error, are:

• ±(0.3% rdg + 1°C) from -50°C to 1000°C
• ±(0.5% rdg + 1°C) from 1000°C to 1300°C
• ±(0.3% rdg + 2°F) from -58°F to 2000°F

The temperature coefficient is specified as 0.1 times the applicable accuracy specification per °C outside the standard operating range (from 0°C to 18°C and 28°C to 50°C). The display updates at a rate of 2.5 times per second.

Input Protection

The instrument accepts a maximum input voltage of 24V dc or 24V ac rms on any combination of input pins. Exceeding these voltages may result in electrical shock; users must not use the instrument when measurement surface voltages exceed this limit.

Configuration Options

The series is configured as a single portable unit with the following documented capabilities:

• Sensor Input: Accepts standard miniature thermocouple connectors (flat blades spaced 7.9mm, center to center) for K-type sensors.
• Display & Resolution: Features a 3½ digit liquid crystal display (LCD) with a maximum reading of 1999. User-selectable resolution options include 1°C or 0.1°C and 1°F or 0.1°F.
• Power Supply: Operates on a standard 9V battery, providing approximately 200 hours typical life with a carbon zinc battery.
• Housing & Dimensions: The unit measures 192mm(H) x 91mm(W) x 52.5mm(D) and weighs 365g.

The temperature scale is user-selectable between Celsius or Fahrenheit.

Key Product Differences

The HH501DK Series is identified by the model number guide "HH501DK". The series supports ISO 9001 certification in the USA and ISO 9002 certification in the United Kingdom. No alternative housings, process connections, or wetted materials are documented for this portable meter configuration.

• 4 Inputs with Differential Temperature Measurement
• 3 1 /2 Digital Display with Backlighting
• Measures K Thermocouples in °F or °C
• Read HOLD, MAX Function
Additional Features 1Read HOLD,MAX Function
Battery Indication“+ -” is displayed when battery voltage drops below operating level
Diameter53 mm
Display Type Note3 1⁄2 digit liquid crystal display (LCD) with maximum reading of 1999 Default Display Output : Zero : Automatic
Electrical ConnectionSub-D Male Miniature Connector
Height195 mm
Measuring Temperature Range, Max1300 °C
Measuring Temperature Range, Min-50 °C
Number of Channels4
Operating Temperature, Max50 °C
Operating Temperature, Min0 °C
Operating Temperature Note0 to 50°C (32 to 122°F)@ <70% RH
Overrange(OL) or (-OL) is displayed
PolarityAutomatic, positive implied, negative polarity indication
Relative Humidity, Max0.8
Relative Humidity, Min0%
Sampling Rate2.5 Hz (2.5 updates/second)
Series IDHH501DK-Series
Storage Temperature, Max60 °C
Storage Temperature, Min-20 °C
Storage Temperature Note-20 to 60°C (-4 to140°F), 0 to 80% RH with battery removed from meter
Supply Voltage9 Vdc
Temperature Accuracy± 0.3%
Temperature Accuracy Note± (0.3% rdg + 1°C) -50 to 1000°C; ± (0.5% rdg + 1°C) 1000 to 1300°C; ± (0.3% rdg + 2°F) -58 to 1999°F Stated accuracy : 23°C ± 5°C <75% relative humidity (accuracy specification does not include
Temperature Resolution0.1 °C
Temperature Sensor TypeThermocouple
Thermocouple TypeK
Weight250 g
Weight NoteApproximately 250 g (9 oz) including battery
Width92 mm
  • Download

    Manual - HH501DK 4 Channel K Type Thermocouple Meter NIST Traceable

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more