Skip to main content
Press Enter
OMEGA

I-7513 DIN-Rail Mountable RS-485 3 Way Converter Hub

RS-485 3 Way Converter Hub

Normally ships in
2-3 weeks
Have questions? We're here to help!
Have questions? We're here to help!

Supported Applications

The Omega I-7513 Series is a 3-channel RS-485 Active Star Wiring Hub designed for industrial communication networks. It functions as both a hub and repeater, enabling the connection of multiple devices to an RS-485 network while maintaining signal integrity over extended distances.

Key application capabilities include:

• Extending RS-485 transmission signals up to 1,200 m (at 9.6 kbps) or 400 m (at 115.2 kbps).
• Supporting star-wiring topologies with three independent output channels.
• Cascading configurations where each output channel can connect to another hub via its repeater function.

Operating Conditions & Performance

The I-7513 Series operates within an ambient temperature range of -25 °C ~ +75 °C and a storage temperature range of -30 °C ~ +75 °C. It is rated for humidity levels between 10 ~ 90% RH, non-condensing.

Performance specifications include:

• Baud Rate Support: Auto-switching from 300 to 115200 bps via an internal Self-Tuner ASIC.
• Isolation: Three-way isolation rated at 3000 VDC between input and output interfaces.
• Device Capacity: Supports up to 256 devices per channel (total of three channels).
• Cabling Recommendation: Belden 8941 (2P twisted-pair cable) for optimal transmission distance; distances may vary with different cables.

Power and Environmental Ratings

• Input Voltage Range: +10 VDC ~ +30 VDC (Non-isolated).
• Power Consumption: 2.16 W.
• Enclosure Rating: IP-411.
• Housing Material: Plastic with Fire Retardant Materials (UL94-V0 Level).

Certifications

The series carries CE, FC, and RoHS approvals.

Configuration Options

The I-7513 Series is configured for DIN-Rail mounting with a compact footprint of 72 mm x 122 mm x 35 mm. It features removable terminal blocks for electrical connections and includes LED indicators for Power (Red) and Data Transmission (Green).

Electrical Connections

The device utilizes two removable 10-Pin Terminal Blocks, providing a total of 20 terminals with the following pin assignments:

• Input Channel: Terminals 01 (DATA+), 02 (DATA-).
• Power Input: Terminal 09 ((R)+Vs) and Terminal 10 ((B)GND).
• Output Channels:
    • Data Channel 3: Terminals 11 (DATA3-) and 12 (DATA3+).
    • Data Channel 2: Terminals 14 (DATA2-) and 15 (DATA2+).
    • Data Channel 1: Terminals 19 (DATA1-) and 20 (DATA1+).

Available Options & Accessories

The series supports the following power supply options:

• GPSU06U-6: 24 VDC/0.25 A, 6 W Power Supply.
• DIN-KA52F: 24 VDC/1.04 A, 25 W Power Supply with Din-Rail Mounting.

Housing Variants

The series is offered in two model configurations based on enclosure color:
• I-7513 CR: Three Way Isolated RS-485 Active Star Wiring Hub (RoHS).
• I-7513-G CR: Three Way Isolated RS-485 Active Star Wiring Hub with Gray Cover (RoHS).

Key Product Differences

The primary distinction between the I-7513 Series models is the enclosure color. The standard model, I-7513 CR, features a default housing finish, while the I-7513-G CR variant includes a gray cover. Both variants share identical electrical specifications, isolation ratings (3000 VDC), and communication capabilities.
The series is designed specifically as an RS-485 Star Wiring Hub; it does not function as a sensor or measurement device for physical quantities such as temperature, pressure, or flow.

• RS-485 Active Star Wiring Applications
• Hub & Repeater Functions, 1 RS-485 to 3RS-485
• Auto Switching Baud Rate, 300 to 115,200 bps
• ESD Protection for the RS-485 Data Line
Baud Rate300 to 115200
Baud Rate NoteMax. 1,200 m for at speed 9.6 kbps; Max. 400 m at 115.2 kbps
Cable Length4000 ft
Cable NoteBelden 8941 (2P twisted-pair cable), if different cables are used, the transmission distance may change
Cable Type2P Twisted-Pair Cable, 4P Twisted-Pair Cable
Data Interface Note3, RS485 Channels: Data+, Data-
Height4.8 in
Input Cable Connector TypeRS485: 10 - Pins Terminal Block, Removable
Input Type1, RS485 Channel: Data+, Data-
IsolationThree Way Protection: 3000 Vdc
LED IndicatorsPower/Communication LED
Length1.5 in
MaterialsABS
MountingDIN-Rail Mounting
Number of Channels1
Number of Wires2
Operating Temperature, Min-25 °C
Output Cable Connector TypeRS485
Power Consumption2.16 W
Relative Humidity10 to 90% RH, Non-Condensing
Self TunerYes, Asic Inside
Series IDI-7513-Series
Storage Temperature, Max75 °C
Storage Temperature, Min-30 °C
Supply Power TypeDC
Supply Voltage10 to 30 Vdc
Supported Devices256 (each channel)
Transmission Distance4000 ft
Width2.83 in

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more