ILD44-UTP-C4EI Large Display Meters & PID Controllers, Colour Changing Display

Large Display Meters & PID Controllers

Normally ships in
2-3 weeks
Have questions? We're here to help!
Have questions? We're here to help!
Configure

Supported Applications

The Omega iLD Series comprises large-display digital panel meters and PID controllers designed for universal temperature monitoring, process measurement, strain gage applications, AC current/voltage sensing, frequency/pulse/rate totalization, and remote display via serial or Ethernet inputs. The series supports thermocouple types J, K, T, E, R, S, B, C, N, L (ITS 90) and RTD sensors (100/500/1000 Ω Pt, ITS 68). Configurable for industrial process control, the units feature programmable color-changing displays that shift between RED, AMBER, and GREEN at set points or alarm conditions.

Operating Conditions & Performance

The iLD Series operates within an ambient temperature range of 0 to 40°C (32 to 104°F) with up to 90% RH non-condensing. A warm-up period of 60 minutes is required for UTP, SP, FP, ACC, and ACV models to achieve rated accuracy. Accuracy specifications vary by input model: Universal Temperature/Process (UTP) offers ±0.5°C temperature or 0.03% reading process; Strain/Process (SP) provides 0.03% reading; Frequency/Pulse (FP) achieves ±0.1% of FS with crystal time-based accuracy of ±50 ppm at 25°C; AC Current (ACC) and AC Voltage (ACV) models specify ±0.2% of FS across their respective frequency ranges.

Response times are documented as a step response of 0.7 sec for 99.9% final value on UTP and SP inputs, while ACC and ACV models respond in 2 s to 99% (filter time constant = 64). FP models with RS485 output achieve 0.1 s to 99%. The reading rate is 3 samples per second across the series.

Configuration Options

The iLD Series offers extensive configuration options for display size, input type, and communication protocols:

• Display Sizes & Digits: Available with 57 mm (2.25") or 101 mm (4") LED digits in either 4-digit or 6-digit configurations.
• Housing & Mounting: Units mount flush in a panel or on the surface using included brackets. The enclosure provides NEMA 4 (IP65) protection for the entire unit, with specific front bezel ratings also noted as NEMA 4 (IP65).
• Input Models:
    • UTP: Universal temperature and process inputs including thermocouples, RTDs, voltage (0 to 100 mV, 0 to 1 V, 0 to 10 Vdc), and current (0 to 20 mA).
    • SP: Strain gage and process inputs with linearization points up to 10.
    • ACC/ACV: Dedicated AC Current ranges (10 mA, 100 mA, 1 A, 5 A) and AC Voltage ranges (400 mV, 4 V, 40 V, 400 V).
    • FP: Frequency/Pulse/Rate inputs from 0.2 Hz to 50 KHz with totalize modes.
• Communication Options:
    • -C24: Isolated RS232 and RS485/422 output (baud rate 300 to 19.2 kB).
    • -EI: Ethernet, RS232, RS485/422 output.
    • -C4EI: Ethernet with embedded Web server + RS485/422 hub for up to 31 devices (IEEE 802.3, 10 Base-T).
• Control & Alarms: Optional -33 suffix provides 2 relays form C SPDT 3 A @ 120/240 Vac for UTP and SP models only. Alarm 1 and 2 are programmable with high, low, band, latch/unlatch operations.
• Power Supply: Universal input of 100 to 240 Vac ±10%, 50/60 Hz (22.5 W).

Key Product Differences

The series distinguishes models by display size and digit count, indicated in the model code: "iLD2" denotes a 57 mm (2.25") display while "iLD4" indicates a 101 mm (4") display; the following number specifies digits (e.g., iLD24 is 4-digit, iLD26 is 6-digit). Input functionality varies by suffix: UTP and SP models support relay outputs (-33) and full PID control features including setpoint adjustment from -1999 to 9999 counts. FP, ACC, and ACV models focus on frequency and electrical measurements with standard RS485 output or optional Ethernet/serial configurations (-EI). Remote display variants (C2/EI suffixes) accept serial or network inputs for monitoring without local sensor connections.

• UL and cUL Certified
• BIG Bright 2.25'(57.2 mm) or 4.00'(101.6 mm) LED Display
• Program to Change Colors: RED, AMBER, GREEN
• Temperature and Process Input Models
A/D ConversionDual slope
Accuracy± 0.5 °C
Accuracy Detail±0.5°C temperature; 0.03% rdg
Alarm modesBand, High/Low, Latch/Unlatch, Normally Open/Closed, Process/Deviation
Common Mode Rejection120 dB
Control ModeReverse (heat) or direct (cool)
Current Measurement Range0 to 20 mA
Data Interface NoteEthernet : Standards compliance IEEE 802.3 10Base-T Supported Protocols : TCP/IP, ARP, HTTPGET RS232/RS422/RS485/MODBUS : Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status. RS485 : Screw terminals
Display ColorRed, Green, Amber
Display Size57.2 mm (2.25 in)
Display Type4 Digit, 7 Segment LED
Display Type Note4-digit or 6-digit, 7-segment LED 57.2 mm (2.25") or 101.6 mm (4.00") red, green and amber programmable colors for process variable, set point and temperature units
Electrical ConnectionScrew Terminal
Enclosure RatingsIP65, NEMA Type 4
Excitation Voltage NoteOptional in Place of Communication
Impedance Input10 MΩ for 100 mV, 1 MΩ for 1 or 10 Vdc
Input TypeThemocouple, RTD, Current, Voltage
IsolationPower to Input/Output: 2300 Vac per 1 min test (RS232/485, input or output) Between Inputs: 500 Vac per 1 min test
Normal Mode Rejection60 dB
Offset Adjustment-1999 to +9999
Operating Temperature, Max40 °C
Operating Temperature, Min0 °C
PolarityUnipolar
Power Consumption22.5 W
Reading Rate3 samples/sec
Relative Humidity90% RH non-condensing
Resolution1°/0.1°; 10 µV process
RTD Type100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; α= 0.00385 or 0.00392
Sensor/Transmitter Power24 Vdc @ 25 mA
Series IDiLD-Series
Set Point Adjustment-1999 to 9999 counts
Span Adjustment0.001 to 9999 counts, programmable
Step Response0.7 sec for 99.9%
Supply Power Note100 to 240 Vac ±10%, 50/60 Hz
Supply Voltage100 to 240 Vac
Temperature StabilityRTD: 0.04°C/°C;Thermcouple @ 25°C (77°F): 0.05°C/°C—cold junction
Thermocouple Lead Resistance, Max100 Ω
Thermocouple TypeJ, K, T, E, N, R, S, B, C, L
Voltage Measurement Range0 to 100 mV, 0 to 1 V, 0 to 10 Vdc
Warm-Up to Rated Accuracy60 min
  • Download

    Data Sheet - ILD44-UTP-C4EI Large Display Meters & PID Controllers, Colour Changing Display

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more