IN-USBH USB in-line field calibratable signal conditioner
USB In-Line Field Calibratable Signal Conditioner
Supported Applications
The Omega IN-USBH is a USB In-Line Field Calibratable Signal Conditioner designed for mV pressure or load transducers. It enables the direct connection of these sensors to a computer, utilizing free PC software to function as a virtual meter, chart recorder, and data logger on laptops or Windows® tablets with USB connections.
The device supports applications requiring dynamic measurement or slow-moving process monitoring by providing adjustable sampling rates up to 1000 Hz. Logged data can be exported in spreadsheet format for later viewing and analysis.
Operating Conditions & Performance
The IN-USBH operates within an ambient temperature range of -40 to 80°C (-40 to 176°F). It provides a resolution of up to 5.5 significant figures with a 24-bit A/D conversion and maintains a linearity error of 0.001% FSO. The thermal error is specified as 0.001% FSO/°C.
Performance specifications include a bandwidth typical of up to 1000 updates per second (±3%) and minimum isolation of 2 MΩ @ 50 Vdc from case to output terminations. The unit provides regulated excitation at 4.1 Vdc* directly to the transducer, eliminating the need for an external power supply.
Transducer requirements are defined as follows:
• Bridge Sensitivity: 1 to 400 mV/V
• Bridge Resistance: 350Ω to 15,000Ω
Configuration Options
The series features a compact in-line design with an overall length of 101 (4.00) mm and a diameter of ø22 (0.88) mm. The housing is constructed from a 316L Stainless Steel Case, weighing approximately 200 g (7.1 oz) including the USB cable.
Connectivity options include:
• Transducer Side Connection: PTIH-10-6P 6-pin twist-lock male connector
• Mating Connector: PT06F10-6S (sold separately)
• USB Side Connection: 2 m (6') USB 2.0 cable
The IN-USBH is field-calibratable using two-point or datasheet parameters via the included software. A stainless steel mounting bracket is included with the unit.
Cable Assembly Options
Pre-made interconnecting cable assemblies (CA*INUSBH) are available to connect specific transducers to the IN-USBH. These cables feature different insulation types and wiring codes tailored to various Omega sensor families:
• PVC Insulation (-30 to 80°C / -22 to 176°F): Available for load cells (LC series) and pressure transducers (PX, LCHD).
• FEP Insulation (-55 to 125°C / -67 to 257°F): Offered for high-temperature applications with specific PX series models.
• Cable Lengths: Standard assemblies are listed at 0.15 m (implied by part number suffix), though lengths longer than 15' may be available upon contacting sales.
Key Product Differences
The primary model, IN-USBH, is the field-calibratable USB in-line signal conditioner. The series supports various configurations through optional pre-made cable assemblies (CA*INUSBH) that match specific transducer wiring codes and connector types.
Differences between available cables are defined by:
• Insulation Material: PVC or FEP, determining the temperature rating of the assembly.
• Wiring Code: Codes such as 2A, 3, 4/4A, 5, 6, and 8 correspond to specific pinout arrangements for different transducer families (e.g., LC111, PX35, LCHD).
• Connector Types: Assemblies may terminate in PT06F10-6S or MS3106E-14S-6S connectors on the transducer side to match specific sensor interfaces.
| ADC Resolution | 24 bit |
| Approvals | CE |
| Bridge Resistance | 350 to 15000 Ω |
| Cable Length | 2 m |
| Diameter | 22 mm |
| Electrical Connection | MIL-26482-I 10-6P, USB A |
| Input Electrical Connection | MIL-26482-I 10-6P |
| Input Range | 1 to 400 mV/V |
| Input Type | Voltage |
| Isolation | 2 MΩ @ 50 Vdc case to output terminations |
| Length | 101 mm |
| Linearity Error | 0.001%/°C |
| Mating Connector | PT06F10-6S |
| Mounting | Mounting Bracket |
| Operating Temperature, Max | 80 °C |
| Operating Temperature, Min | -40 °C |
| Resolution | Up to 5.5 |
| Sensor Excitation | 4.1 Vdc (Excludes the PX309 and PX409 series) |
| Series ID | IN-USBH-Sig-Cond |
| Weight | 200 g |
| Zero/Balance Error | 0.001%/°C |
OMEGACA-6TE24-6-015-INUSBH
6 conductor, FEP insulation, Wiring Code 6, connectors on both ends, 15 ft standard length
Call Today!
800-567-8686Normally ships in 2-3 weeks
OMEGACA-6PC24-4-015-INUSBH
6 conductor, PVC insulation, Wiring Code 4, connectors on both ends, 15 ft standard length
Call Today!
800-567-8686Normally ships in 2-3 weeks
OMEGACA-6PC24-3-015-INUSBH
6 conductor, PVC insulation, Wiring Code 3, connectors on both ends, 15 ft standard length
Call Today!
800-567-8686Normally ships in 2-3 weeks
OMEGACA-6PC24-0-003-INUSBH
6 conductor, PVC insulation, Wiring Code 0, connector on IN-USBH end and flying leads on transducer end, 3 ft length
Call Today!
800-567-8686Normally ships in 2-3 weeks
OMEGACA-6PC24-2A-015-INUSBH
6 conductor, PVC insulation, Wiring Code 2A, connectors on both ends, 15 ft standard length
Call Today!
800-567-8686Normally ships in 2-3 weeks
OMEGACA-6PC24-8-015-INUSBH
6 conductor, PVC insulation, Wiring Code 8, connectors on both ends, 15 ft standard length
Call Today!
800-567-8686Normally ships in 2-3 weeks
OMEGACA-6TE24-3-015-INUSBH
6 conductor, FEP insulation, Wiring Code 3, connectors on both ends, 15 ft standard length
Call Today!
800-567-8686Normally ships in 2-3 weeks
OMEGACA-6PC24-4A-015-INUSBH
6 conductor, PVC insulation, Wiring Code 4A, connectors on both ends, 15 ft standard length
Call Today!
800-567-8686Normally ships in 2-3 weeks
OMEGACA-6TE24-5-015-INUSBH
6 conductor, FEP insulation, Wiring Code 5, connectors on both ends, 15 ft standard length
Call Today!
800-567-8686Normally ships in 2-3 weeks
OMEGAPT06F10-6S
Environmentally protected connector with 6 female contacts, -55 to 125°C (-67 to 257°F) temperature range
Call Today!
800-567-8686Normally ships in 2-3 weeks