Skip to main content
Press Enter
OMEGA

IN-UVI Wheatstone Bridge In-Line Amplifier w/ Field Selectable I/O

Wheatstone Bridge In-Line Amplifier

Normally ships in
2-3 weeks
Have questions? We're here to help!
Have questions? We're here to help!

Supported Applications

The Omega IN-UVI series is a Wheatstone bridge in-line signal conditioner designed for use with miniature transducers, including load cells and pressure transducers. It connects between the sensor and a readout instrument or data acquisition (DAQ) system to convert millivolt signals into standardized voltage or current outputs. The rugged stainless steel enclosure supports deployment where space is limited or environments are hostile.

Operating Conditions & Performance

The IN-UVI operates within an ambient temperature range of -20 to 60°C (0 to 140°F) and provides IP65 environmental protection. It accepts a supply voltage of 22 to 32 Vdc, isolated from the output by 500 Vdc with 100 MΩ resistance. The device features programmable bridge excitation at either 5 or 10 Vdc (field selectable) and supports sensor input ranges from 0.5 mV/V to 4 mV/V in 0.5 steps.

Performance specifications include a linearity of ±0.01% of FS, long-term zero drift of 0.1%/year of FS, and temperature effects of ±0.001%/°F for zero (auto-zero front end) and ±0.0025%/°F for span. The response time is documented as 200 μS (0 to 63%) for a 350 Ω bridge and 1.2 mS for a 5,000 Ω bridge.

Configuration Options

The series offers configurable output signals including voltage options of ±5 Vdc or ±10 Vdc (at 2 mA max) and current outputs of 4-20 mA or 12 mA zero ±8 mA. The maximum load resistance is rated at 700 Ω at 20 mA for current mode, with an output resistance of 60 Ω.

Key configurable features include:

• Excitation Voltage: Field programmable selection between 5 Vdc or 10 Vdc (max excitation current 30 mA @ 10 Vdc).
• Sensor Input Range: Supports bridge sensitivities of 1 to 8 mV/V at 5 Vdc EXC, and 0.5 to 4 mV/V for 10 Vdc EXC.
• Bridge Resistance Compatibility: Accepts transducer resistances from 350 to 5,000 Ω.
• Calibration Features: Includes a buffered solid-state shunt calibration feature that can be remotely activated for field checking and adjustment. Zero adjustment range is ±30% of FS; span adjustment offers ±20% fine and ±40% coarse ranges, accessible behind connector endcaps.
• Electrical Connections: Available with M12 connectors (5-pin or 8-pin) or flying leads. Accessories include the M12.5-S-F-FM for sensor connection and M12.8-S-F-FM for input/output connections, both featuring cable glands.

Key Product Differences

The IN-UVI series is identified by the model number guide CA-4PC24-2A-xxx-INUVI structure when configured with specific Omega cable assemblies. Standard cable part numbers are available for various transducer types, including load cells (e.g., LC111, LCHD) and pressure sensors (e.g., PX35, PX6000). The physical dimensions of the unit are 134.8 mm L x 34.8 mm H x 31.2 mm D (5.3 x 1.37 x 1.23 in), with a diameter of 31.2 mm (1.23 in). The series carries CE certification and includes a one-year warranty.

• Wide Range of Field Selectable Inputs and Outputs
• Ready-Made Cable Assemblies for Transducer Connection Now Available!
• Input/Output Isolation
• Low Thermal Drift
ApprovalsCE
Bridge Resistance350 to 5000 Ω
Calibration NoteField Installed Shunt Calibration resistor with remote activation for bridge calibration
Capacitance0.022 µF
EMC<0.15% of FS per EN61326-1 (industrial)
Enclosure RatingsIP65
Height34.8 mm
Input Noise10 mV peak to peak @ 3 mV/V voltage mode (10 Vdc) 20 uA peak to peak current mode
Input Range90 mA, 0.5 mV/V to 4 mV/V in 0.5 steps
Input Range NoteCurrent: 90 mA maximum (must be capable of supplying 200 mA), Sensor Input: 0.5 mV/V to 4 mV/V in 0.5 steps
Input TypeCurrent, Signal
Isolation100 MΩ @ 500 Vdc
Length134.8 mm
Linearity0.0001
Load Resistance700 Ω at 20 mA
Long Term Stability0.1% of FS/year
Operating Temperature, Max60 °C
Operating Temperature, Min-20 °C
Output DetailCurrent: 4 to 20 mA, 12 mA zero ± 8 mA outputs field programmable, Voltage: ± 5 volts, ± 10 volts at 2 mA maximum
Output Resistance60 Ω
ProtectionShort Circuit Protection: Yes +output to -output
Response Time200 µs
Response Time Note200 µs (0 to 63%)
SensitivityBridge : 1 to 8 mV/V @ 5 Vdc EXC, 0.5 to 4 mV/V for 10 Vdc EXC
Sensor Excitation5 or 10 Vdc field programmable; 30 mA @ 10 Vdc
Series IDIN-UVI-Bridge-Amplifier
Span Adjustment± 20 % fine ± 40 % coarse
Supply Power22 to 32 Vdc
Supply Power Note22 to 32 Vdc isolated from output
Supply Power TypeDC
Thermal Span Effect0.0025%/°F
Thermal Zero Effect0.001%/°F
Trim Pot AccessBehind connector endcaps
Width31.2 mm
Zero Setting Adjustable Range± 30%

 • Use with Miniature Load Cells

• Extent the range of mV/V Pressure Transducers
• Wheatstone Bridge Transducers
  • Download

    Data Sheet - IN-UVI Wheatstone Bridge In-Line Amplifier w/ Field Selectable I/O

    Download
  • Download

    Manual - IN-UVI Wheatstone Bridge In-Line Amplifier w/ Field Selectable I/O

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more