IN-UVI Wheatstone Bridge In-Line Amplifier w/ Field Selectable I/O
Wheatstone Bridge In-Line Amplifier
Supported Applications
The Omega IN-UVI series is a Wheatstone bridge in-line signal conditioner designed for use with miniature transducers, including load cells and pressure transducers. It connects between the sensor and a readout instrument or data acquisition (DAQ) system to convert millivolt signals into standardized voltage or current outputs. The rugged stainless steel enclosure supports deployment where space is limited or environments are hostile.
Operating Conditions & Performance
The IN-UVI operates within an ambient temperature range of -20 to 60°C (0 to 140°F) and provides IP65 environmental protection. It accepts a supply voltage of 22 to 32 Vdc, isolated from the output by 500 Vdc with 100 MΩ resistance. The device features programmable bridge excitation at either 5 or 10 Vdc (field selectable) and supports sensor input ranges from 0.5 mV/V to 4 mV/V in 0.5 steps.
Performance specifications include a linearity of ±0.01% of FS, long-term zero drift of 0.1%/year of FS, and temperature effects of ±0.001%/°F for zero (auto-zero front end) and ±0.0025%/°F for span. The response time is documented as 200 μS (0 to 63%) for a 350 Ω bridge and 1.2 mS for a 5,000 Ω bridge.
Configuration Options
The series offers configurable output signals including voltage options of ±5 Vdc or ±10 Vdc (at 2 mA max) and current outputs of 4-20 mA or 12 mA zero ±8 mA. The maximum load resistance is rated at 700 Ω at 20 mA for current mode, with an output resistance of 60 Ω.
Key configurable features include:
• Excitation Voltage: Field programmable selection between 5 Vdc or 10 Vdc (max excitation current 30 mA @ 10 Vdc).
• Sensor Input Range: Supports bridge sensitivities of 1 to 8 mV/V at 5 Vdc EXC, and 0.5 to 4 mV/V for 10 Vdc EXC.
• Bridge Resistance Compatibility: Accepts transducer resistances from 350 to 5,000 Ω.
• Calibration Features: Includes a buffered solid-state shunt calibration feature that can be remotely activated for field checking and adjustment. Zero adjustment range is ±30% of FS; span adjustment offers ±20% fine and ±40% coarse ranges, accessible behind connector endcaps.
• Electrical Connections: Available with M12 connectors (5-pin or 8-pin) or flying leads. Accessories include the M12.5-S-F-FM for sensor connection and M12.8-S-F-FM for input/output connections, both featuring cable glands.
Key Product Differences
The IN-UVI series is identified by the model number guide CA-4PC24-2A-xxx-INUVI structure when configured with specific Omega cable assemblies. Standard cable part numbers are available for various transducer types, including load cells (e.g., LC111, LCHD) and pressure sensors (e.g., PX35, PX6000). The physical dimensions of the unit are 134.8 mm L x 34.8 mm H x 31.2 mm D (5.3 x 1.37 x 1.23 in), with a diameter of 31.2 mm (1.23 in). The series carries CE certification and includes a one-year warranty.
| Approvals | CE |
| Bridge Resistance | 350 to 5000 Ω |
| Calibration Note | Field Installed Shunt Calibration resistor with remote activation for bridge calibration |
| Capacitance | 0.022 µF |
| EMC | <0.15% of FS per EN61326-1 (industrial) |
| Enclosure Ratings | IP65 |
| Height | 34.8 mm |
| Input Noise | 10 mV peak to peak @ 3 mV/V voltage mode (10 Vdc) 20 uA peak to peak current mode |
| Input Range | 90 mA, 0.5 mV/V to 4 mV/V in 0.5 steps |
| Input Range Note | Current: 90 mA maximum (must be capable of supplying 200 mA), Sensor Input: 0.5 mV/V to 4 mV/V in 0.5 steps |
| Input Type | Current, Signal |
| Isolation | 100 MΩ @ 500 Vdc |
| Length | 134.8 mm |
| Linearity | 0.0001 |
| Load Resistance | 700 Ω at 20 mA |
| Long Term Stability | 0.1% of FS/year |
| Operating Temperature, Max | 60 °C |
| Operating Temperature, Min | -20 °C |
| Output Detail | Current: 4 to 20 mA, 12 mA zero ± 8 mA outputs field programmable, Voltage: ± 5 volts, ± 10 volts at 2 mA maximum |
| Output Resistance | 60 Ω |
| Protection | Short Circuit Protection: Yes +output to -output |
| Response Time | 200 µs |
| Response Time Note | 200 µs (0 to 63%) |
| Sensitivity | Bridge : 1 to 8 mV/V @ 5 Vdc EXC, 0.5 to 4 mV/V for 10 Vdc EXC |
| Sensor Excitation | 5 or 10 Vdc field programmable; 30 mA @ 10 Vdc |
| Series ID | IN-UVI-Bridge-Amplifier |
| Span Adjustment | ± 20 % fine ± 40 % coarse |
| Supply Power | 22 to 32 Vdc |
| Supply Power Note | 22 to 32 Vdc isolated from output |
| Supply Power Type | DC |
| Thermal Span Effect | 0.0025%/°F |
| Thermal Zero Effect | 0.001%/°F |
| Trim Pot Access | Behind connector endcaps |
| Width | 31.2 mm |
| Zero Setting Adjustable Range | ± 30% |
• Use with Miniature Load Cells
OMEGAM12.5-S-F-FM Field Mountable M12 & M8 Connectors
Field Mountable M8 and M12 Connectors
Call Today!
800-567-8686Normally ships in 2-3 weeks
OMEGACA-4PC24-3-015-INUVI Wheatstone Bridge In-Line Amplifier
Cable assembly, 4 conductor, PVC insulation, wiring code 3
Call Today!
800-567-8686Normally ships in 2-3 weeks
OMEGACA-4PC24-2A-015-INUVI
Cable assembly, 4 conductor, PVC insulation, wiring code 2A
This product is no longer available. Contact us at 800-567-8686 for alternative solutions.
OMEGACA-4PC24-4-015-INUVI
Cable assembly, 4 conductor, PVC insulation, wiring code 4
This product is no longer available. Contact us at 800-567-8686 for alternative solutions.
OMEGACA-4TE24-6-015-INUVI
Cable assembly, 4 conductor, FEP insulation, wiring code 6
Call Today!
800-567-8686Normally ships in 2-3 weeks
OMEGACA-4PC24-0-015-INUVI Wheatstone Bridge In-Line Amplifier
Cable assembly, 4 conductor, PVC insulation, wiring code 0
Call Today!
800-567-8686Normally ships in 2-3 weeks
OMEGACA-6PC24-OUT-015-INUVI Wheatstone Bridge In-Line Amplifier
Cable assembly, 6 conductor, PVC insulation, wiring code OUT
Call Today!
800-567-8686Normally ships in 2-3 weeks
OMEGAM12.8-S-FM Field Mountable M12 & M8 Connectors
Field Mountable M8 and M12 Connectors
Call Today!
800-567-8686Normally ships in 2-3 weeks