Skip to main content
Press Enter
Starting at $580.00CAD
Configure
INOR

IPAQ C530 / C530X Universal HART-Compatible 2-Wire Tx

HART® temperature transmitter compatible w/ RTD, thermocouples, voltage & potentiometer sensors, wireless communication

Starting at
$580.00CAD
Have questions? We're here to help!
Have questions? We're here to help!
Configure

IPAQ C530 is a modern, HART® temperature transmitter developed to meet the highest standards of accuracy and reliability. A universal transmitter compatible with RTD, thermocouples, voltage and potentiometer sensors, offering high flexibility and reduces the number of installed product variants.

It is fully compatible with HART® 7 and offers extended diagnostic information (for example device error, sensor and wiring conditions) making it reliable and highly precise.

IPAQ C530 supports communication via NFC® (Near-field communication) and Bluetooth® which makes it possible to configure and monitor the transmitter remotely.

• NFC - Configuration of the transmitter via a portable device such as a smartphone.
• HART® 7 protocol
• High accuracy and long-term stability
• Efficient PC-configuration without external power

Sensor errorNAMUR NE43
Error compensationSensor and system error correction
* Bluetooth® communication is only supported together with ICON-BT
TypeHead-mounted
InputRTD, TC, mV, ohm
Input RTDPt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
Input thermocoupleType B, C, D, E, J, K, N, R, S, T
Type of transmitterDigital
Output4-20 mA, HART protocol
Galvanic isolation1500 VAC
Measuring channels1 channel
Sensor connection2-, 3-, 4-wire connection
Power supplyIPAQ-C530: 8,5 to 36 VDC
IPAQ-C530X: 8,5 to 30 VDC
ApprovalsATEX, IECEx
HART® complianceFully compliant with the HART® 7 protocol
as well as the previous HART® 6 and 5.
Typical accuracyMax. ±0.08K or ±0.08% of span
Accuracy over timeMax. drift ±0,02% of span/year
ConfigurationConSoft, INOR Connect or EDD, DTM / FDT-system
Wireless connectivityNFC® and Bluetooth® *
VibrationIEC 60068-2-6, 10 g
EMCEN 61326-1 and EN 61326-2-3
Humidity0…98% RH (non-condensing)
Ambient temperature–40…+85 °C / -40…+185 °F
Runtime counterHour counter for elapsed operational time
Simulated outputFixed current ouput during a maximum time of 15 min
Adjustable filtering level0,17 to 90 s (standard 0.9 s) (3-wire RTD)
Adjustments – Min. span10°C / 18°F or according to the sensor
Adjustments – Zero pointAny value within range limits
  • Thumbnail of document Manual - IPAQ C530 / C530X Universal HART-Compatible 2-Wire Tx
    Download

    Manual - IPAQ C530 / C530X Universal HART-Compatible 2-Wire Tx

    Download
  • Thumbnail of document Data Sheet - IPAQ C530 / C530X Universal HART-Compatible 2-Wire Tx
    Download

    Data Sheet - IPAQ C530 / C530X Universal HART-Compatible 2-Wire Tx

    Download

Accessories

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more