Skip to main content
Press Enter
OMEGA

LVU501 Reflective Ultrasonic Level Transmitter

Reflective Ultrasonic Liquid Level Transmitter with Alarm Contacts (4) for Small Tanks

Normally ships in
3-4 weeks
Have questions? We're here to help!
Have questions? We're here to help!
Configure

Supported Applications

The Omega LVU500 Series is a reflective ultrasonic level transmitter designed for continuous measurement in small tanks. The series utilizes proprietary Reflective Technology™ to provide reliable distance or range measurements between the transducer and process media, specifically engineered for condensing environments. Documented applications include day tanks, IBCs (Intermediate Bulk Containers), drums, cooling towers, skids, process tanks, and waste sumps.

The series is suitable for measuring chemicals, water, wastewater, and oil, provided the liquids are non-foaming and/or not highly vaporous. The transmitter provides a 4 to 20 mA analog signal output alongside four SPST relays for alarm or control functions in general-purpose classifications.

Operating Conditions & Performance

The LVU500 Series operates within an ambient temperature range of -31° to 140°F (-35° to 60°C) and a process temperature range of -40° to 176°F (-40° to 80°C). The unit features automatic temperature compensation. Pressure ratings are specified at 30 psi (2 bar), with derating applied @ 1.667 psi per degree C above 25 °C.

Performance specifications vary by model range:

• Lvu501 Range: Measures from 1.5" to 4.9" (3.8 cm to 1.5 m) with an accuracy of ±0.125" (3 mm), a resolution of 0.019" (0.5 mm), and a dead band of 1.5" (3.8 cm).
• Lvu503 Range: Measures from 4' to 9.8' (10.1 cm to 3 m) with an accuracy of ±0.2% of range, a resolution of 0.039" (1 mm), and a dead band of 4" (10.1 cm).

Both models share a beam width of 2" (5 cm). The enclosure is rated IP68 / NEMA Type 6P.

Voltage & Signal Specifications

• Power Supply: 14-28 VDC with maximum consumption of 0.5W.
• Loop Resistance: 500 ohms @ 24 VDC.
• Analog Output: 4 to 20 mA, two-wire; configurable for signal invert (4-20 mA or 20-4 mA).
• Fail-Safe Options: Signal fail-safe can be set to 4 mA, 20 mA, 21 mA, 22 mA, or hold last value.

Contact Specifications

• Type: (4) SPST relays rated at 60 VA, 1A maximum.
• Fail-Safe Behavior: Configurable for power loss to hold last value; contact fail-safe options include open, closed, or hold last on power-on.
• Hysteresis: Selectable per relay configuration.

Configuration Options

The LVU500 Series offers configurable process connections and interface options to accommodate specific installation requirements. The housing is constructed from Polypropylene (PP-FR GF30), while the transducer element utilizes Polyvinylidene Fluoride (PVDF). Electrical connectivity is provided via a 9-conductor, shielded cable with a polyurethane jacket.

Process Connections & Mounting

The series supports two primary process mount configurations:

• NPT Thread: 2" NPT connection (standard for models LVU501 and LVU503).
• G Thread: 2" G connection, which includes an FKM gasket.

Additional mounting accessories are available to extend installation flexibility, including bulkhead fittings in PVC (schedules 40 and 80) for various thread/socket combinations ranging from 3" to 4", as well as side mount brackets made of Polypropylene for both NPT and G threads.

Configuration & Interface

The transmitter features non-volatile memory and is configured via WebCal® PC Windows® software using a USB interface. Variants are available with or without the included LVU500-USB FOB (Fob) for programming:

• With Interface: Models ending in no suffix or "G" include the Fob.
• Without Interface: Models suffixed with "B" are supplied without the USB interface.

Key Product Differences

The LVU500 Series is differentiated primarily by measurement range and process connection type, resulting in distinct physical dimensions for each model family. The series includes eight enabled variants covering all combinations of range (LVU501 vs. LVU503), thread standard (NPT vs. G/BSPP), and USB interface inclusion.

Model Dimensions

The physical footprint varies between the short-range and long-range models:

• Lvu501 Family: Height 1.75" (44.5 mm), Width 2.9" (73.7 mm), Diameter 1.5" (38.1 mm).
• Lvu503 Family: Height 4.0" (101.6 mm), Width 2.75" (69.9 mm), Diameter 1.96" (49.8 mm).

The cable length is specified as 4' (121.9 cm) for the series, with a diameter of 1.875" (47.6 mm). The internal wiring includes dedicated conductors for power (+/-), transmit/receive signals, and four relay outputs plus common.

Compliance & Approvals

The LVU500 Series carries CE and RoHS compliance markings. Additionally, the series meets UL 61010-1 standards for safety in laboratory equipment environments.

  • Designed to handle condensing environments
  • Offered in 1.5 m (4.9’) and 3 m (9.8’) measurement ranges
  • Fail-safe diagnostics with 4 selectable relays and signal outputs
  • Narrow 2” (5 cm) beam width for applications with limited space
Approvalsul61010_1
Beam Width2 in
Cable Length48 in
Cable TypeInsulated Shielded
ConfigurationWebCal® PC Windows® USB® 2.0
Contact Fail-SafeOpen, Closed, Hold Last
Diameter2.9 in
Electrical Output4 to 20 mA
Enclosure RatingsNEMA 6 to 30P for 240V
Height4 in
InsulationPolyurethane
Loop Resistance500 Ω @ 24 Vdc
MaterialsFKM, Fluoroelastomer, Polycarbonate, Polyvinylidene, Fluoride
Mean HysteresisSelectable
MemoryNon - Volatile
Number of Wires2
Operating Pressure, Max30 psi
Operating Temperature, Max60 °C
Operating Temperature, Min-35 °C
Output SignalCurrent
Process Connection Size2 in
Process Temperature, Max80 °C
Process Temperature, Min-40 °C
Series IDLVU500-Series
Signal fail-safe4 mA, 20 mA, 21 mA, 22 mA or hold last
Signal invert4 to 20 mA or 20 to 4 mA
Supply Voltage14 to 28 Vdc
Switch Rating60 VA,1A max
Switch TypeSPST
Temperature CompensationAutomatic
Transducer TypeReflective Ultrasonic
  • Download

    Data Sheet - LVU501 Reflective Ultrasonic Level Transmitter

    Download
  • Download

    Manual - LVU501 Reflective Ultrasonic Level Transmitter

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more