Supported Applications

The ALTA Industrial Wireless Three Phase Current Meter measures the RMS current of an alternating current (AC) system using three current transformers (CTs) that wrap around the conductors of a three-phase power system. It reports minimum, maximum, and average RMS current, duty cycle for each phase, and the combined amp hours of all three phases to the iMonnit system, making it ideal for energy monitoring, motor and pump load profiling, and predictive-maintenance programs across industrial facilities.

Because data is delivered wirelessly to iMonnit, the meter suits distributed installations where running signal cable is impractical. Readings are pushed on every heartbeat or immediately when current exceeds configured thresholds, so operators can trend consumption and catch abnormal load conditions in near real time.

Operating Conditions & Performance

The meter uses 0-150 amp current transducers, with an absolute maximum CT current of 200 Amps RMS (Arms) and a maximum accurate CT current of 150 Arms over a frequency range of 50-100 Hz. Accuracy is +/- 2% @ 2 to 150 Arms, +/- 0.4 Arms @ < 15 Arms, improving to +/- 1% @ 2 to 150 Arms, +/- 0.2 Arms @ < 2 Arms when calibrated with an appropriate offset. Offset limits run from -1.27 to + 1.27 Arms (default set to +0.3 Arms).

Measurement resolution is 0.01 Arms average, 1 Arms maximum and minimum, 1% duty, and 0.1 Amp Hours. The default averaging interval is 5 seconds. Each of the three current transformers ships with 3 ft wires and measures 67 mm x 49 mm x 42 mm (24 mm inner diameter).

The sensor operates over -40°C to +85°C (-40°F to +185°F) and runs on 2.0-3.8 VDC (3.0-3.8 VDC using power supply) from an included 1500 mAh battery. Integrated memory holds up to 3200 sensor messages and wireless range is 1,200+ ft non-line-of-sight, secured with Encrypt-RF® (256-bit key exchange and AES-128 CTR). The sealed, weatherproof enclosure is NEMA 1, 2, 4, 4x, 12 and 13 rated and weighs 28.7 ounces. Certifications include FCC, CE, Industry Canada, and UL Listed to UL508-4x specifications (File E194432).

Configuration Options

This series is offered as a single, fully featured three-phase configuration that bundles all three current transformers, wireless radio, and the complete measurement set — per-phase minimum, maximum, and average RMS current plus duty cycle and combined amp hours. There are no reduced-channel or scaled-down variants; every unit delivers the full 0-150 Arms three-phase capability described above.

Field capability can be extended with an optional solar feature comprising a 5VDC/30mA solar panel (53mm x 30mm) and a 600 mAh rechargeable battery rated for >2000 charge cycles. With the solar option, the charging temperature range is 0°C to 45°C (32°F to 113°F) and the maximum temperature range is -20°C to 60°C (-4°F to 140°F), supporting continuous unattended operation in remote locations.

Key Product Differences

• MNS2-9-IN-3P-150 — ALTA Wireless Three Phase 150 Amp AC Current Meter, supplied with three 0-150 amp current transformers and 3 ft CT wires.

The base sensor can be paired with the optional solar feature (5VDC/30mA panel and 600 mAh rechargeable battery) for power-autonomous deployments.

  • For Measuring 3-Phase AC Current Up to 150A
  • Extended Non-Line-of-Sight Range (1,200 Ft Through 12-14 Walls Typical)
  • AES-128 CBC Data Encryption
  • Local Storage of 512 Messages for Data Assurance
Accuracy± 2 %
Accuracy DetailCurrent Transformer: ± 2% @ 2 to 150 Arms, ± 0.4 Arms @ < 15 Arms; Calibration Accuracy: Current Transformer: ±1% @ 2 to 150 Arms, ± 0.2 Arms @ < 2 Arms
ApprovalsCE, FCC, UL
Approvals NoteFCC ID: ZTL- G2SC1 and IC: 9794A-G2SC1, UL Listed to UL508-4x specifications (File E194432)
Battery lifeup to 10 yr
Battery Size and TypeAlkaline AA
Cable Length3 ft
CalibrationCalibrate at a current between 30% and 90% of max accurate range
Current Measurement Range0 to 150 A
Data InterfaceWireless
Electrical ConnectionCable
Enclosure RatingsNEMA 4, NEMA Type 1, NEMA Type 12, NEMA Type 13, NEMA Type 2, NEMA Type 4X, Weatherproof
Form factorWall Mount
Frequency50 to 100 Hz
Height2.559 in
Inner Diameter0.94 in
Length1.579 in
Current, Max200 Amps RMS
MemoryUpto 3200 sensor messages
Number of Channels1
Number of Sensors3
Operating Temperature, Max85 °C
Operating Temperature, Min-40 °C
Operating Temperature Note-40°C to +85°C (board circuitry and battery)
Power Consumption22.6 mA
Power Consumption NoteSleep Mode:0.2 µA, RTC Mode:0.7 µA, MCU Idle:570 µa, MCU Active:2.5 mA, Radio RX Mode:5.5 mA, Radio TX Mode:22.6 mA
ResolutionCurrent Transformer: 1 Arms
Resolution NoteCurrent Transformer: Average: 0.01 Arms, Max: 1 Arms, Min: 1 Arms, Duty: 1%, Amp Hours: 0.1 Amp Hours
Sensor Length2.63 in
Sensor Thickness1.65 in
Sensor Width1.92 in
Series IDAlta-3P-Current
Supply Power NoteDC: 2.0 - 3.8 VDC (3.0 - 3.8 VDC using power supply), Solar panel: 5VDC/30mA (53mm x 30mm), Charging temperature range: 0°C to 45°C (32°F to 113°F), Max temperature range: -20°C to 60°C (-4°F to 140°F), Included rechargeable battery: 600 mAh/>2000 charge cycles (80% of initial capacity), Solar efficiency: Optimized for high and low-light operation
Supply Power TypeDC/Battery
Supply Voltage2.0 to 3.8 Vdc
Weight28.7 oz
Width7.07 in
  • Download

    Data Sheet - MNS2-9-IN-3P-150 Monnit Alta Wireless 3 phase 150 Amp AC Current Meters

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more