MNS2-9-W2-LS-LM Monnit Alta Wireless Light Level Meters

ALTA Wireless Light Meter - AA Battery Powered (900 MHz)

Normally ships in
2-3 weeks
Have questions? We're here to help!
Have questions? We're here to help!

Supported Applications

The Omega Alta Wireless Light Meter series measures light intensity and detects the presence or absence of light. The product overview identifies suitability for light-sensitive applications including museums, art galleries, and industrial environments.

Operating Conditions & Performance

The series utilizes a highly sensitive photodiode to measure light levels from 0–83,000 LUX with an accuracy of 0.5% of reading. Data is transmitted wirelessly via Encrypt-RF® (256-bit key exchange and AES-128 CTR) security protocols.

Operating temperature ranges vary by model configuration:

• Commercial AA Wireless Light Meter: -18°C to 55°C (0°F to 130°F) using alkaline batteries; -40°C to 85°C (-40°F to 185°F) using lithium batteries.
• Industrial Wireless Light Meter: -40°C to +85°C (-40°F to +185°F).

The Commercial AA model includes an optimal battery temperature range of +10°C to +50°C (+50°F to +122°F). Wireless transmission supports a range of 1,200+ ft non-line-of-sight.

Power and Electrical Specifications

The series operates on a supply voltage of 2.0–3.8 VDC (3.0–3.8 VDC using power supply). Current consumption varies by mode: 0.2 μA (sleep), 0.7 μA (RTC sleep), 570 μA (MCU idle), 2.5 mA (MCU active), 5.5 mA (radio RX), and 22.6 mA (radio TX). The Industrial model includes a battery with 1500 mAh capacity.

Approvals and Certifications

Certifications include FCC, CE, and Industry Canada. Specific identifiers are:

• 900 MHz product: FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1.
• 433 MHz product: Tested to comply with EN 300 220-2 V3.1.1 (2017-02) and EN 60950.

The Industrial model is UL Listed to UL508-4x specifications (File E194432).

Configuration Options

The series offers two primary configurations with distinct physical and environmental characteristics:

• Commercial AA Wireless Light Meter: Features a black plastic housing. Dimensions are 4.375 in width, 2.470 in height, and 3.295 in depth; weight is 3.7 ounces.
• Industrial Wireless Light Meter: Features clear plastic with a gray base. It carries an enclosure rating of NEMA 1, 2, 4, 4x, 12 and 13 rated, sealed and weatherproof. Dimensions are 3.701 in width, 1.378 in height, and 2.316 in depth; weight is 4.8 ounces.

Power options include two replaceable 1.5 V AA batteries for the standard version or a line-powered option with backup AA batteries utilizing a barrel power connector. The series supports integrated memory of up to 3200 sensor messages and includes access to the free iMonnit basic online wireless sensor monitoring and notification system.

Key Product Differences

The Commercial AA model is intended for general use, while warnings specify not to use commercial grade sensors in corrosive, flammable, dusty, high-pressure, wet, or vibrating environments. The Industrial model provides the NEMA 1, 2, 4, 4x, 12 and 13 rated enclosure suitable for harsher conditions.

Both models share identical measurement ranges (0–83,000 LUX), accuracy (0.5% of reading), wireless security protocols, and supply voltage requirements. The primary distinctions lie in the operating temperature envelope when using alkaline batteries, physical dimensions, weight, housing material, and environmental ratings.

  • Measures Light Levels and Transmits Wirelessly
  • Extended Non-Line-of-Sight Range (1,200 Ft Through 12-14 Walls Typical)
  • AES-128 CBC Data Encryption
  • Local Storage of 512 Messages for Data Assurance
Accuracy± 0.5 %
Accuracy DetailLight: 0.5%
ApprovalsCE, FCC
Approvals NoteFCC ID: ZTL- G2SC1 and IC: 9794A-G2SC1
Battery Operating Temperature10 to 50 °C
Data InterfaceWireless
Display TypeN/A
Electrical ConnectionN/A
Enclosure MaterialN/A
Form factorWall Mount
Height2.47 in
Input Range0 to 83000 lx
Input TypePhotodiode
Length1.111 in
MemoryUpto 3200 sensor messages
Number of Channels1
Operating Temperature, Max85 °C
Operating Temperature, Min-40 °C
Operating Temperature Note-18°C to 55°C (0°F to 130°F) using alkaline, -40°C to 85°C (-40°F to 185°F) using lithium
Power Consumption22.6 mA
Power Consumption NoteSleep Mode:0.2 µA, RTC Mode:0.7 µA, MCU Idle:570 µa, MCU Active:2.5 mA, Radio RX Mode:5.5 mA, Radio TX Mode:22.6 mA
Probe Diameter0 in
Probe Length0 in
Series IDAlta-Light
Sheath MaterialN/A
Supply Power NoteDC: 2.0 - 3.8 VDC (3.0 - 3.8 VDC using power supply), Solar panel: 5VDC/30mA (53mm x 30mm), Charging temperature range: 0°C to 45°C (32°F to 113°F), Max temperature range: -20°C to 60°C (-4°F to 140°F), Included rechargeable battery: 600 mAh/>2000 charge cycles (80% of initial capacity), Solar efficiency: Optimized for high and low-light operation
Supply Power TypeDC/Battery
Supply Voltage2.0 to 3.8 Vdc
Temperature Probe StyleN/A
Weight3.7 oz
Width4.375 in
Wire Length0 ft
  • Download

    Data Sheet - MNS2-9-W2-LS-LM Monnit Alta Wireless Light Level Meters

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more