Skip to main content
Press Enter
OMEGA

OM-CP Ambient Temperature & Thermocouple Data Logger, NOMAD Family

Ambient Temperature and Thermocouple Data Logger, Part of the NOMAD Family

Normally ships in
3-4 weeks
Have questions? We're here to help!
Have questions? We're here to help!

Supported Applications

The Omega OM-CP-TC101A is a dual-channel data logger from the NOMAD® family designed for ambient temperature monitoring and remote thermocouple measurements. It supports field deployment with programmable high/low alarms, memory wrap-around functionality, and ultra-high-speed download capabilities via USB interface.

Operating Conditions & Performance

The device operates within an ambient temperature range of -40 to 80°C (-40 to 176°F) with a humidity rating of 0 to 95% RH non-condensing. It features dual-channel capability: one internal channel for ambient temperature and one remote input accepting thermocouple types J, K, T, E, R, S, B, and N.

Performance specifications vary by sensor type:

• Ambient Channel: Range of -40 to 80°C (-40 to 176°F) with ±0.5°C (0.9°F) accuracy and 0.1°C resolution.
• Type J, K, T, E, N Thermocouples: Accuracy of ±0.5°C; ranges span from -270 to 1370°C depending on type.
• Type R, S, B Thermocouples: Accuracy of ±2.0°C with a resolution of 0.5°C and high-temperature capability up to 1820°C for Type B.

The logger offers a memory capacity of 1,000,000 readings at a reading rate as fast as 1 second. Power is supplied by a user-replaceable 3.6V lithium battery with an estimated life of 10 years.

Configuration Options

The series supports various configuration options and accessories to extend functionality for specific environments or compliance needs:

• Housing Options: The standard unit features ABS plastic. A weatherproof NEMA 4 (IP65) enclosure (OM-CP-WATERBOX101A), constructed from black anodized aluminum, is available separately for outdoor or harsh environments.
• Data Retrieval & Software: Data retrieval requires the OM-CP-IFC200 Windows software and 1.8 m (6') USB interface cable. The device supports real-time monitoring, graphical/tabular display, and export to Excel.
• Compliance Options: An FDA 21 CFR part 11 compliant IQ/OQ/PQ secure software validation workbook is available as the OM-CP-SVP-SYSTEM package.
• Maintenance & Calibration: Replacement batteries (OM-CP-BAT105) and optional NIST calibration certificates (model suffix -CERT) are offered. A maintenance kit for the waterproof enclosure is also available.

The thermocouple input utilizes a female subminiature (SMP) connector. The device dimensions are 36 L x 56 W x 16 mm D (1.4 x 2.2 x 0.6") for the logger alone, and 74 H x 148 W x 39 mm D (2.9 x 5.8 x 1.5") when installed in the waterproof enclosure.

Key Product Differences

The primary model distinction within this series is the inclusion of an optional NIST calibration certificate, designated by the suffix -CERT (e.g., OM-CP-TC101A-CERT). The base unit includes a battery life indicator and free firmware upgrades. Thermocouple accuracy specifications assume the use of 24 AWG wire.

• Dual Channel/Ambient and Remote 

• 10 Year Battery Life 

• 1 Second Reading Rate 

• NIST Certified

Alarm DelayProgrammable time delay
Battery lifeup to 10 yr
Battery Size and Type3.6V Li-ion
Data InterfaceUSB
Data Interface NoteUSB (interface cable required); 115,200 baud
Electrical ConnectionSub-D Female Miniature Connector
LED IndicatorsGreen LED Blinks: 10 second rate to indicate logging 15 second rate to indicate delay start mode
MaterialsABS
Measurement TypeTemperature
Memory1000000
Memory Note1,000,000 readings;software configurable memory wrap 500,000 readings in multiple start/stop mode or trigger settings mode
Number of Measurements2
Operating Humidity0 to 95% RH
Operating Temperature, Max80 °C
Operating Temperature, Min-40 °C
Process Temperature, Max80 °C
Process Temperature, Min-40 °C
Real Time RecordingThe device may be used with PC to monitor and record data in real-time
Recorder Height36 mm
Recorder Length56 mm
Recorder Width16 mm
Samples,Max1000000
Sampling Rate1 Hz (1 update/second)
Sampling Rate Note1 reading every second to 1 every 24 hours.
Series IDOM-CP-TC101A-Logger
Software CompatibilityWindows® XP/VISTA/7 and 8 (32- and 64-bit)
Supply Power TypeBattery
Temperature Resolution0.1 °C
Thermocouple Resistance, Max100 Ω
Time Accuracy± 1 minute/month
Waterbox Depth39 mm
Waterbox Height74 mm
Waterbox Width148 mm
Weight24 g
  • Download

    Data Sheet - OM-CP Ambient Temperature & Thermocouple Data Logger, NOMAD Family

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more